Overview
- Seams continuously welded and ground smooth
- Seamless foam-in-place gasket on all doors and covers
- Smoke gray 0.25-in.-thick polycarbonate window on upper front door
- Quarter-turn latches on upper front door for 1400-mm high cabinets
- ProLine latching system and key locking swing door handles on upper front door for 1600- and 1800-mm high cabinets
- Solid lower front and full rear doors with key locking swing door handles
- Internal rails facilitate mounting of ProLine internal components
- Options include solid upper front door and solid front and rear covers with screw fasteners
- Full rear opening provides maximum mounting space and easy access to interior components
- Optional partial subpanel
Specifications
Application | Controls and Drives |
Bottom Door Opening Height | 27.91 in |
Bottom Door Opening Height | 29.09 in |
Bottom Door Opening Width | 28.98 in |
Bottom Door Opening Width | 21.1 in |
Color | Light Gray |
Color | Gray |
Color | Grey |
Color Code | RAL 7035 |
Depth | 23.62 |
Depth | 600 |
Depth | 600 mm |
Finish | Powder Coating |
Finish | Powder Coated |
Height | 1,400 mm |
Height | 55.12 |
Height | 1,400 |
IP Rating | IP55 |
Material | Mild Steel |
Material | Steel |
Material | Mild Steel;Steel |
Modification Services | Yes |
Mounting Type | Unibody Steel Construction with Mounting Rails |
Nema Rating | Type 12 |
NEMA Rating | 12 Indoor, dust-resistant |
NEMA Rating | 12 |
Nominal Depth | 800 mm |
Nominal Depth | 600 mm |
Nominal Height | 1,800 mm |
Nominal Height | 1,400 mm |
Nominal Width | 600 mm |
Nominal Width | 800 mm |
Product Family | ProLine |
Protection Rating | NEMA Type 12 |
Rear Door Opening Height | 57.25 in |
Rear Door Opening Height | 1,711 mm |
Rear Door Opening Height | 1,454 mm |
Rear Door Opening Width | 536 mm |
Rear Door Opening Width | 28.98 in |
Series | ProLine Gold |
Size | 1400x800x600 mm |
Size | 1400x800x600mm |
Top Door Opening Height | 16 in |
Top Door Opening Height | 406 mm |
Top Door Opening Height | 558 mm |
Top Door Opening Width | 28.98 in |
Top Door Opening Width | 536 mm |
Type | Mild Steel Modular Industrial Enclosures |
Type Number | Type 12 |
Weight | 283 lb |
Width | 31.5 |
Width | 800 |
Width | 800 mm |
Package Dimensions (L x W x H) | 37.5 IN x 30.5 IN x 65 IN |
Package Dimensions (L x W x H) | 95.25 cm x 77.47 cm x 165.1 cm |
Package Weight (Imperial) | 283.000 L |
Package Weight (Metric) | 128.369 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyHow to Install the PGLD1486CWS Controller
This guide provides step-by-step instructions for the installation and initial setup of the PGLD1486CWS Controller, ensuring proper wiring and configuration.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Wire connectors, Power supply
- Mount the controller
Secure the PGLD1486CWS Controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.
- Connect the power supply
Using wire connectors, connect the power supply wires to the controller's power input terminals. Verify the connections are secure and insulated to prevent short circuits.
- Configure initial settings
Power on the controller and access the configuration menu. Set the desired operational parameters such as voltage and current limits according to the specifications provided in the user manual.
- Calibrate the controller
Use a multimeter to measure the output voltage and current. Adjust the calibration settings in the controller until the output matches the desired specifications.
- Test the installation
Run a test operation to ensure the controller is functioning correctly. Monitor the output and verify that all settings are as configured.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.