nVent PDW188 - ProLine Window Doors, fits 1800x800mm, Aluminum, Polycarbonate
nVent

PDW188

UPC: 783510910303


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine PDW188 (SKU: PDW188) is a robust 1800x800mm window door designed for ProLine G2 equipment enclosures. Constructed with a durable aluminum frame, it provides clear visibility of internal components. Available with either smoke-gray tinted polycarbonate or clear safety glass, this door meets diverse viewing requirements. It features a secure 3-point latching mechanism and 140-degree hidden hinges for optimal access, with an optional 180-degree hinge kit for expanded maneuverability. Engineered for front or rear mounting on ProLine G2 frames, the PDW188 is ideal for critical applications in telecommunications, data centers, and industrial automation. Its flush bezel design effectively minimizes dust and moisture ingress, ensuring a tight seal. The 0.25-inch thick window is field-replaceable for convenient maintenance. Integrating seamlessly with the standard door bar system, nVent's ProLine Window Doors facilitate easy accessory attachment, offering reliable sealing and access to your valuable equipment.
  • Install easily on front or rear of enclosure frame; can be hinged on left or right
  • Have two grounding brackets
  • Have a .25-in.-thick window that provides maximum protection and viewing area
  • Have foam-in-place urethane gaskets for door and window to provide optimum sealing
  • Flush bezel design for dust and moisture resistance
  • Field-replaceable 0.25-inch thick window
  • Front or rear mounting capability
  • Compatible with standard door bar system for accessory attachment

Specifications

Application
Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
1800 x 800 mm
Material
Aluminum, Polycarbonate
Material
Mild Steel
Modification Services
Yes
Product Family
ProLine
Safety Glass
68.46 x 31.22 in
Safety Glass
1739 x 793 mm
Size
fits 1800x800mm
Size
1800x800mm
Thickness
14 ga
Thickness
1.9 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
46 lb
Window Door Type
Mild Steel and Polycarbonate
Window Size
1618 x 646 mm
Window Size
63.69 x 25.42 in
Package Dimensions (L x W x H)
71.46 IN x 34.85 IN x 1.88 IN
Package Dimensions (L x W x H)
181.5084 cm x 88.519 cm x 4.7752 cm
Package Weight (Imperial)
46.000 L
Package Weight (Metric)
20.866 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the PDWG86 Controller

This guide provides step-by-step instructions for installing and configuring the PDWG86 Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the PDWG86 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Using wire strippers, prepare the power supply wires and connect them to the designated terminals on the controller. Verify the connections are secure.

  3. Configure the controller settings

    Power on the controller and use the interface to set the desired parameters. Follow the on-screen instructions to complete the initial configuration.

  4. Calibrate the controller

    Perform a calibration check by following the calibration procedure outlined in the manual. Use a multimeter to verify output readings.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.