nVent PDS78RHF2 - Solid Doors, fits 700x800mm, EMC
nVent

PDS78RHF2

UPC: 783510134792


Documents & Media
Installation Instructions

Contact for Pricing

Overview

Enhance your industrial enclosure's protection with the nVent PDS78RHF2 Medium EMI/RFI Solid Door, specifically designed to fit 700x800mm enclosure frames. Engineered by nVent, a trusted leader in electrical enclosure solutions, this solid door provides robust shielding against electromagnetic interference (EMI) and radio frequency interference (RFI), crucial for maintaining the integrity and performance of sensitive electronic equipment in demanding industrial environments. The PDS78RHF2 is constructed for durability and ease of use, ensuring reliable operation and long-term protection. This solid door features a sophisticated 3-point latching system, operated by a flush bezel latch, for secure closure. For enclosures with 700mm frames, a 2-point latching system is implemented, offering appropriate security levels. Doors exceeding 700mm in height or 400mm in width are equipped with a convenient removable door bar system, facilitating easier access and maintenance. The hinge side is reversible, allowing for flexible installation configurations to suit your specific layout requirements. Hidden hinges, providing a 130-degree swing, enable attachment to either the front or back of the enclosure frame, further enhancing installation versatility. For applications requiring side mounting, the PDS78RHF2 can be seamlessly integrated using a side-door adapter or a cable entry cabinet, expanding its applicability across various industrial setups. Key benefits of the nVent PDS78RHF2 include: * **Superior EMI/RFI Shielding:** Protects sensitive electronics from disruptive interference, ensuring operational stability and data integrity. * **Robust Construction:** Built with high-quality materials for resilience in harsh industrial conditions. * **Versatile Installation:** Reversible hinges, front/back mounting options, and compatibility with side-door adapters offer flexible deployment. * **Secure Latching:** Features a reliable 3-point or 2-point latching system for secure enclosure access. * **User-Friendly Design:** Includes a removable door bar system on larger doors for enhanced accessibility. This nVent solid door is an ideal choice for industries such as telecommunications, manufacturing, data centers, and any sector where reliable protection of electronic components from environmental and electromagnetic factors is paramount. The UNSPSC code 39121334 categorizes this product under electrical enclosure accessories, highlighting its essential role in complete system protection. Manufactured in the USA, the PDS78RHF2 embodies nVent's commitment to quality and performance in electrical infrastructure solutions.
  • EMC doors are finished with paint over plated surfaces
  • Optional data pockets, door stops, grounding kits and 180-degree hinges are available
  • Hinges have easy slide retained hinge pins
  • Door gasket is foam-in-place urethane to provide a resilient, seamless seal
  • Two grounding studs are furnished. All mounting hardware is included

Specifications

Application
Controls and Drives;Power Distribution
Application
Power Distribution; Controls and Drives
Color
Light Gray
Color
Gray
Color
Grey
Color Code
RAL 7035
Dimensions
28W x 10D x 10H IN
Dimensions
25.16 x 31.18 in
Door Type
EMC
Fits Frame
700 x 800 mm
IP Rating
IP55
Material
Mild Steel
Material
Mild Steel;Steel
Modification Services
Yes
Product Family
ProLine
Size
700x800 mm
Size
fits 700x800mm
Thickness
1.9 mm
Thickness
14 ga
Thickness
51.40mm (2.024")
Type
External Mounting for ProLine Industrial Enclosures
Weight
22.82 lb
Works With
NEMA
Package Dimensions (L x W x H)
33 IN x 27.5 IN x 2.5 IN
Package Dimensions (L x W x H)
83.82 cm x 69.85 cm x 6.35 cm
Package Weight (Imperial)
22.820 L
Package Weight (Metric)
10.351 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the PDS78RHF2 Controller

This guide provides step-by-step instructions for installing and configuring the PDS78RHF2 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the PDS78RHF2 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use wire connectors to connect the power supply wires to the designated terminals on the controller. Verify that the connections are secure and insulated.

  3. Configure initial settings

    Power on the controller and use the interface to set the initial configuration parameters as per your system requirements. Refer to the user manual for specific settings.

  4. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate readings and performance. Use a multimeter to verify output signals.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.