nVent PDS228SS - Solid Doors, fits 2200x800mm, SS 304
nVent

PDS228SS

UPC: 783510314590


Documents & Media
Installation Instructions

Contact for Pricing

Overview

Enhance the security and integrity of your industrial enclosures with the nVent PDS228SS Solid Door. Crafted from high-grade SS 304 stainless steel, this robust door is engineered to fit 2200x800mm enclosure frames, providing a reliable barrier against environmental factors and unauthorized access. nVent is a globally recognized leader in enclosure solutions, renowned for delivering durable and high-performance products that meet the stringent demands of industrial applications. The PDS228SS embodies this commitment to quality and functionality. Designed for versatility and ease of use, this solid door incorporates several advanced features. For doors exceeding 700mm in height or 400mm in width, a convenient removable door bar system is integrated, simplifying installation and maintenance. The hinge side is reversible, offering maximum flexibility during the enclosure assembly process, allowing it to be configured for left-hand or right-hand opening as per site requirements. Operation is intuitive and secure, thanks to a flush bezel latch that actuates a robust 3-point latching system. This ensures a tight seal and superior protection for the sensitive equipment housed within the enclosure. For smaller frames (700mm), a reliable 2-point latching system is employed, maintaining the same high standards of security. Installation is streamlined with hidden hinges that provide a 130-degree swing, allowing for ample access to the enclosure's interior. These hinges can be attached to either the front or back of the enclosure frame, offering further adaptability. For applications requiring side mounting, the PDS228SS can be seamlessly integrated using a side-door adapter or a dedicated cable entry cabinet, expanding the configuration possibilities for complex industrial setups. The SS 304 stainless steel construction offers excellent corrosion resistance, making it ideal for use in harsh environments, including chemical processing plants, food and beverage facilities, and outdoor installations where exposure to moisture and corrosive agents is a concern. Key features of the nVent PDS228SS Solid Door include: * **Durable SS 304 Construction:** Provides superior corrosion resistance and longevity. * **Optimized Fit:** Specifically designed for 2200x800mm enclosure dimensions. * **Advanced Latching System:** Features a 3-point latching mechanism (2-point for 700mm frames) operated by a flush bezel latch for enhanced security. * **Flexible Installation:** Reversible hinge side and hidden 130-degree swing hinges for adaptable mounting. * **Integrated Door Bar System:** Removable system for doors taller than 700mm or wider than 400mm. * **Seamless Integration:** Compatible with side-door adapters and cable entry cabinets for side mounting. This solid door is an essential component for any industrial electrical or automation enclosure, ensuring the protection of critical components from dust, moisture, and tampering. Trust nVent for reliable enclosure solutions that safeguard your operations.
  • Robust SS 304 stainless steel construction for superior corrosion resistance.
  • Designed to fit 2200x800mm industrial enclosure frames.
  • Features a secure 3-point latching system operated by a flush bezel latch.
  • Integrated removable door bar system for enhanced accessibility on larger doors.
  • Hidden 130-degree swing hinges with reversible hinge side for flexible installation.

Specifications

Application
Controls and Drives;Power Distribution
Color
Unpainted
Dimensions
28W x 10D x 10H IN
Dimensions
84.21 x 31.18 in
Door Type
Stainless Steel
Finish
Brushed
Fits Frame
2200 x 800 mm
Material
SS 304 Stainless Steel
Material
Stainless Steel 304
Material
Stainless Steel;Stainless Steel 304
Modification Services
Yes
Mounting Type
Front or rear attachment with 130-degree swing hinges
Product Family
ProLine
Series
nVent PDS Series
Size
fits 2200x800mm
Size
2200x800mm
Thickness
1.9 mm
Thickness
14 ga
Thickness
51.40mm (2.024")
Type
External Mounting for ProLine Industrial Enclosures
Weight
80 lb
Works With
NEMA
Package Dimensions (L x W x H)
86 IN x 33 IN x 3 IN
Package Dimensions (L x W x H)
218.44 cm x 83.82 cm x 7.62 cm
Package Weight (Imperial)
80.000 L
Package Weight (Metric)
36.288 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the PDS78RHF2 Controller

This guide provides step-by-step instructions for installing and configuring the PDS78RHF2 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the PDS78RHF2 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use wire connectors to connect the power supply wires to the designated terminals on the controller. Verify that the connections are secure and insulated.

  3. Configure initial settings

    Power on the controller and use the interface to set the initial configuration parameters as per your system requirements. Refer to the user manual for specific settings.

  4. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate readings and performance. Use a multimeter to verify output signals.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.