Enhance the security and environmental protection of your industrial enclosures with the nVent PDS146SS Solid Door. Crafted from high-grade SS 304 stainless steel, this robust door is engineered to fit 1400x600mm enclosure frames, providing a durable and reliable barrier against dust, moisture, and unauthorized access. The SS 304 material offers exceptional corrosion resistance, making it ideal for demanding environments found in chemical processing, food and beverage manufacturing, water treatment facilities, and outdoor installations where harsh conditions are prevalent. Designed for versatility and ease of use, the nVent PDS146SS features a reversible hinge side, allowing for flexible installation configurations to suit your specific site layout and operational needs. For doors exceeding 700mm in height or 400mm in width, a convenient removable door bar system is integrated, simplifying access and maintenance without compromising security. The door is equipped with a flush bezel latch that smoothly operates a robust 3-point latching system, ensuring a secure and tight seal. Doors designed for 700mm frames utilize a dependable 2-point latching mechanism for optimal closure. Installation is streamlined thanks to the hidden hinges, which allow for a 130-degree swing. These hinges can be attached to either the front or back of the enclosure frame, offering further adaptability. For extended configurations or specialized mounting requirements, the door can be seamlessly attached to the sides of an enclosure frame using a compatible side-door adapter or a dedicated cable entry cabinet. This modular approach ensures that the nVent PDS146SS can be integrated into a wide array of enclosure systems, providing a consistent level of protection and functionality. When selecting enclosure components, reliability and material integrity are paramount. nVent, a trusted leader in electrical enclosure solutions, delivers products that meet stringent industrial standards. The PDS146SS solid door exemplifies this commitment, offering a long-lasting and secure solution for protecting sensitive electrical and electronic equipment. Its SS 304 construction guarantees longevity and performance, even in corrosive or high-humidity settings. Invest in the nVent PDS146SS for superior enclosure protection and peace of mind.
  • Constructed from high-grade SS 304 stainless steel for superior corrosion resistance.
  • Designed to fit 1400x600mm industrial enclosure frames.
  • Features a 3-point latching system operated by a flush bezel latch for enhanced security.
  • Reversible hinge side allows for flexible installation.
  • Includes a removable door bar system on larger doors for easier access and maintenance.

Specifications

Application
Controls and Drives;Power Distribution
Application
Power Distribution; Controls and Drives
Color
Unpainted
Dimensions
28W x 10D x 10H IN
Dimensions
52.72 x 23.31 in
Door Type
Stainless Steel
Finish
Brushed
Fits Frame
1400 x 600 mm
Material
SS 304
Material
Stainless Steel;Stainless Steel 304
Material
Stainless Steel 304
Modification Services
Yes
Mounting Type
Hinges (130-degree swing, reversible)
Product Family
ProLine
Size
fits 1400x600mm
Size
1400x600mm
Thickness
1.52 mm
Thickness
16 ga
Thickness
51.40mm (2.024")
Type
External Mounting for ProLine Industrial Enclosures
Weight
37 lb
Works With
NEMA
Package Dimensions (L x W x H)
54 IN x 25 IN x 3 IN
Package Dimensions (L x W x H)
137.16 cm x 63.5 cm x 7.62 cm
Package Weight (Imperial)
37.000 L
Package Weight (Metric)
16.783 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the PDS146SS Controller

This guide provides step-by-step instructions for installing and configuring the PDS146SS Controller, ensuring proper wiring and calibration.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the PDS146SS controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power supply and input/output wires to the designated terminals on the controller. Ensure all connections are tight and secure.

  3. Configure the controller settings

    Power on the controller and use the interface to set the desired parameters. Follow the manufacturer's guidelines for programming specific functions.

  4. Calibrate the controller

    Perform a calibration check using a multimeter to verify the output signals. Adjust settings as necessary to ensure accurate performance.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.