The nVent ProLine G2 Full Mounting Subpanel (SKU: P2P2210G) is a cutting-edge solution designed for industrial and commercial electrical enclosures, offering unparalleled flexibility, safety, and efficiency in panel mounting applications. Engineered as part of the patent-pending ProLine G2 system, this subpanel features a 2200x1000mm footprint with a galvanized steel construction, ensuring durability and conductivity for high-performance electrical distribution. The conductive design meets stringent industry standards, making it ideal for applications requiring reliable grounding and electromagnetic compatibility. The ProLine G2 Subpanel integrates seamlessly with the innovative EZ-Load Mounting System, a revolutionary feature that transforms how subpanels are loaded into modular enclosures. Unlike traditional mounting methods, the EZ-Load system provides multiple loading options—vertical loading from the front, rear, or side, as well as horizontal loading for enhanced control and precision. This versatility significantly reduces installation time, minimizes risk of damage, and improves overall workflow efficiency, particularly in high-volume or time-sensitive projects. Designed for professionals who demand both performance and ease of use, the ProLine G2 Subpanel is optimized for a wide range of applications, including industrial control panels, data centers, telecommunications infrastructure, and utility distribution systems. Its robust construction and conductive properties make it suitable for environments where electrical safety and system reliability are critical. The subpanel’s large form factor accommodates extensive wiring and component integration, providing ample space for complex configurations without compromising accessibility or maintenance. Industry experts recognize nVent as a leader in thermal management and electrical protection solutions, and the ProLine G2 Subpanel exemplifies this commitment to innovation. With a focus on modularity and scalability, this subpanel allows for future upgrades or reconfigurations with minimal downtime, reducing long-term operational costs. Whether deployed in new construction or retrofitting existing systems, the ProLine G2 delivers consistent performance under demanding conditions. Installation is streamlined thanks to the EZ-Load Glide Blocks, which simplify alignment and reduce the physical strain associated with handling large subpanels. The system’s design also enhances safety by minimizing the need for manual lifting or awkward positioning, a critical consideration in compliance-driven industries. For engineers, contractors, and facility managers seeking a high-quality, future-proof subpanel solution, the nVent ProLine G2 Full Mounting Subpanel (P2P2210G) stands as a benchmark in modular electrical enclosures.
  • Accommodates five loading options: vertical front, vertical side, vertical rear, horizontal front (frame over subpanel), horizontal rear (subpanel lowered into frame)
  • High space efficiency ratio (HxW of subpanel)/(HxW of frame) of 84 percent
  • Mounting subpanel is securely fastened at the top and bottom of the enclosure; subpanels less than 1200mm wide include four sets of EZ-Load Glide Blocks, four BV-M6 fasteners (block to frame) and four M12 Hex Bolts (subpanel to block); Subpanels 1200mm an
  • Subpanels greater than 1000mm wide are 11 gauge (3.0 mm) mild steel, while subpanels 100mm or narrower are 12 gauge (2.5mm); conductive or white painted finish available
  • Subpanels can be mounted at any depth in 25-mm increments (front to back); accommodates back-to-back and fully recessed rear positions
  • Side-mount panels must be used for the sides of the enclosure; they can be installed on the interior sides of frames
  • Optional panel support bracket available for applications requiring more support in the center of the subpanel; this is required if the enclosure will be tipped in transit or if the panel is not located at the bottom of the enclosure on the glide blocks
  • Panels can be installed in the rearmost position, or positioned so joined enclosures provide a continuous mounting surface without requiring joining panels
  • High space efficiency ratio (HxW of subpanel)/(HxW of frame) of 84 percent
  • Side-mount panels must be used for the sides of the enclosure; they can be installed on the interior sides of frames

Specifications

Application
Power Distribution; Controls and Drives
Color
Unpainted
Finish
Galvanized
Fits Frame
2200x1000 mm
Material
Galvanized Steel
Material
Mild Steel
Mounting Type
EZ-Load Mounting System
Mounting Type
Full Mounting Subpanel with EZ-Load Mounting System
Product Family
ProLine
Series
ProLine G2
Size
2200x1000 mm
Size
2200x1000
Thickness
12 ga
Thickness
2.66 mm
Type
Galvanized
Weight
109 lb
Package Dimensions (L x W x H)
88 IN x 41 IN x 2.5 IN
Package Dimensions (L x W x H)
223.52 cm x 104.14 cm x 6.35 cm
Package Weight (Imperial)
109.000 L
Package Weight (Metric)
49.442 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the P2KDR18186 Controller

This guide provides step-by-step instructions for installing and configuring the P2KDR18186 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2KDR18186 controller to the designated mounting surface using the provided mounting screws. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Using wire strippers, prepare the power supply wires and connect them to the appropriate terminals on the controller. Ensure the connections are tight and secure.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals of the controller. Ensure the voltage is within the specified range before powering on the device.

  4. Power on the controller

    Turn on the power supply to the controller and observe the status indicators to ensure the device is functioning correctly.

  5. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters as per your application requirements.

  6. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate operation of the controller.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.