nVent P2K1486 - ProLine G2 Industrial Packages Type 12, 1400x800x600, Lt Gray, Steel
nVent

P2K1486

UPC: 783510319625


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Industrial Packages (SKU: P2K1486) offer a comprehensive, ready-to-deploy enclosure solution designed for demanding industrial environments. Eliminating the need to source individual components, each ProLine G2 package is delivered as a complete unit, streamlining procurement and installation processes. This specific package, measuring 1400x800x600 mm, is constructed from robust steel and finished in a light gray powder coating, providing excellent durability and resistance to corrosion and environmental factors. Its Type 12 NEMA rating signifies suitability for indoor applications where protection against falling dirt, dust, and dripping or light splashing of non-corrosive liquids is paramount. Engineered for efficiency and convenience, the ProLine G2 Industrial Package includes a sturdy frame, solid door(s) equipped with a handle and key lock for secure access, a solid top, and a solid rear cover. A full mounting subpanel is integrated, offering a versatile platform for mounting electrical and electronic equipment. Furthermore, a gland plate is provided for controlled cable entry, ensuring a clean and protected interface. Four lifting eyes are strategically placed for safe and easy handling during transport and installation. Side covers are available separately, allowing for flexible baying or joining of multiple enclosures to create larger, integrated control systems. This nVent enclosure solution is ideal for a wide range of industrial applications, including control panels, automation systems, power distribution, and data acquisition. Industries such as manufacturing, process control, utilities, and telecommunications benefit from the reliability and integrated design of the ProLine G2 series. nVent's commitment to quality and innovation is evident in the robust construction and thoughtful features of these industrial packages, ensuring the protection and longevity of critical equipment. The ease of ordering with a single part number, combined with the high level of pre-assembly, significantly reduces project timelines and labor costs. Professionals can trust nVent to deliver dependable enclosure solutions that meet stringent industry standards and operational requirements.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color Code
RAL 7035
Depth
23.82
Depth
605
Door Quantity
1
Finish
Powder Coated
Height
55.2
Height
1,402
Material
Mild Steel
Max Rack Mount Unit
28
Max Subpanel Size
51.4 x 28.7 in
Max Subpanel Size
1306 x 728 mm
Product Family
ProLine
Type
Mild Steel Modular Industrial Enclosures
Weight
240 lb
Width
31.8
Width
808
Package Dimensions (L x W x H)
38 IN x 31 IN x 63 IN
Package Dimensions (L x W x H)
96.52 cm x 78.74 cm x 160.02 cm
Package Weight (Imperial)
240.000 L
Package Weight (Metric)
108.864 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What frame sizes are available for ProLine G2?

Frame heights range from 600 mm to 2200 mm, with various widths and depths.

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What safety features are included with ProLine G2?

Safety features include mechanical and electrical interlocks, disconnect doors, and barrier panels.

What materials are used for the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel with welded corner blocks.

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models.

How can I configure my ProLine G2 enclosure?

Select components from the configuration handbook and send it to your nVent representative.

What is the maximum load capacity for casters?

Casters can support a maximum load of 1000 lb (453.6 kg) for standard casters.

What types of doors are available for the ProLine G2?

Available door types include solid, window, perforated, and overlapping double doors.

What are the EMC options for ProLine G2?

EMC options are available for various components, including frames and covers.

What is the purpose of the Duro-Stand Gland Plate?

The Duro-Stand Gland Plate provides cable management while maintaining a NEMA 12 rating.

How to Install the P2K1486 Controller

This guide provides step-by-step instructions for installing and configuring the P2K1486 Controller, ensuring proper setup and functionality.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2K1486 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated terminals on the controller. Ensure the connections are tight to prevent any power loss.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals. Ensure the voltage matches the specifications outlined in the controller's manual.

  4. Configure the controller settings

    Access the controller's configuration interface and set the necessary parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the manual to ensure accurate readings and performance. This may involve adjusting settings based on test inputs.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.