nVent P2K1264 - ProLine G2 Industrial Packages Type 12, 1200x600x400, Lt Gray, Steel
nVent

P2K1264

UPC: 783510319342


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Overview

The **nVent ProLine G2 Industrial Package (SKU: P2K1264)** delivers a **pre-engineered, ready-to-install enclosure solution** designed for demanding industrial environments where protection, durability, and ease of deployment are critical. This **Type 12-rated enclosure** (NEMA 12 equivalent) is built to safeguard electrical and electronic components from dust, dirt, and non-corrosive liquids while meeting stringent safety and compliance standards. With a **1200x600x400mm footprint**, this **light gray steel enclosure** combines robust construction with modular flexibility, making it an ideal choice for machine control panels, automation systems, and industrial automation applications. Engineered for **out-of-the-box functionality**, the ProLine G2 package eliminates the complexity of sourcing individual components. Each system includes a **heavy-duty steel frame**, a **solid door with integrated handle and key lock**, a **solid top and rear cover**, a **full mounting subpanel**, a **gland plate**, and **four lifting eyes** for safe handling during installation. Side covers are available separately to support **baying and joining applications**, enabling scalable configurations for expanding industrial setups. The **light gray powder-coated finish** ensures corrosion resistance and a professional appearance, while the **Type 12 rating** guarantees protection against environmental contaminants in indoor industrial settings. Industries such as **manufacturing, food and beverage processing, pharmaceuticals, and wastewater treatment** rely on nVent ProLine G2 enclosures to house critical control systems, PLCs, motor starters, and other sensitive electronics. The **pre-drilled mounting subpanel** simplifies internal component installation, reducing labor time and minimizing errors during assembly. For applications requiring **NEMA 12 compliance**, this enclosure provides a cost-effective alternative to custom-built solutions without compromising on quality or performance. The **US-manufactured** design also ensures adherence to North American industrial standards, offering peace of mind for engineers and facility managers. Installation is streamlined thanks to the **modular design** and **comprehensive hardware package**, which includes all necessary mounting and securing components. The **solid door with key lock** enhances security, while the **gland plate** accommodates cable entry points efficiently. For facilities planning **future expansions**, the ability to **bay multiple enclosures** using optional side covers ensures seamless integration into larger control systems. nVent’s reputation for **innovation and reliability** in industrial enclosure solutions further solidifies this product as a trusted choice for professionals seeking **durability, compliance, and ease of use**. Whether deployed in **automated production lines, HVAC control rooms, or industrial automation hubs**, the ProLine G2 Industrial Package stands out as a **high-performance, low-maintenance solution** that reduces procurement complexity and accelerates project timelines. Backed by nVent’s **decades of expertise in thermal management and electrical protection**, this enclosure is engineered to meet the rigorous demands of modern industrial environments while providing long-term value and operational efficiency.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Power Distribution; Controls and Drives
Color
Light Gray
Color
Lt Gray
Color Code
RAL 7035
Depth
15.94
Depth
405
Door Quantity
1
Finish
Powder Coated
Height
47.2
Height
1,202
Material
Mild Steel
Material
Steel
Max Rack Mount Unit
23
Max Subpanel Size
1106 x 528 mm
Max Subpanel Size
43.5 x 20.8 in
Mounting Type
Modular/Baying
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine G2
Series
ProLine G2 Industrial Packages
Size
1200x600x400
Size
1200x600x400 mm
Type
Mild Steel Modular Industrial Enclosures
Weight
188 lb
Width
23.92
Width
608
Package Dimensions (L x W x H)
30.5 IN x 26 IN x 59 IN
Package Dimensions (L x W x H)
77.47 cm x 66.04 cm x 149.86 cm
Package Weight (Imperial)
188.000 L
Package Weight (Metric)
85.277 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What are the available frame heights for ProLine G2?

Available frame heights include 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, and 2200 mm.

Can I customize the ProLine G2 enclosure?

Yes, the ProLine G2 features a comprehensive set of standard components that can be configured for custom solutions.

What types of doors are available for the ProLine G2?

Available door types include solid, window, perforated, and overlapping double doors.

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What is the maximum load capacity for the mobile base?

The mobile base supports a load-bearing capacity of 1000 lb (453.6 kg).

What is the weight capacity of the pull-out shelf?

The pull-out shelf has a load rating of 110 lbs (50 kg).

What safety features are included with the ProLine G2?

Safety features include mechanical and electrical interlocks to prevent unauthorized access and ensure safe operation.

What accessories are available for cable management?

Accessories include cable entry cabinets, vertical tie-down cable managers, and wire management rails.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.

How can I ensure proper grounding for the enclosure?

Use the Ground Wire Kit or Ground Plate Kit to effectively ground the enclosure to VDE specifications.

How to Install the P2K1264 Controller

This guide provides step-by-step instructions for installing and configuring the P2K1264 Controller for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2K1264 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect power supply

    Connect the power supply wires to the designated terminals on the controller. Ensure the connections are tight and secure to prevent any power loss.

  3. Wire the input/output connections

    Use terminal connectors to wire the input and output devices to the corresponding terminals on the P2K1264. Double-check the wiring diagram to ensure correct connections.

  4. Configure the controller settings

    Power on the controller and access the configuration menu. Set the necessary parameters according to your application needs.

  5. Calibrate the controller

    Perform a calibration of the controller by following the on-screen instructions. Use a multimeter to verify output signals during the calibration process.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.