nVent P2CBD185 - ProLine G2 Sequestr Barrier Panel, 1800x500
nVent

P2CBD185

UPC: 783510368050


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Sequestr Barrier Panel (SKU: P2CBD185) is a critical component for modern industrial enclosures, designed to provide secure segregation between high-voltage/amperage components and adjacent control systems. Manufactured by nVent, a global leader in electrical and thermal management solutions, this barrier panel ensures compliance with safety standards while enabling efficient space utilization in complex electrical installations. The 1800x500mm panel integrates seamlessly with the ProLine G2 Sequestr enclosure system, offering both structural integrity and functional versatility for demanding industrial environments. This barrier panel is engineered to join enclosures while maintaining strict separation between hazardous and non-hazardous zones, making it ideal for applications where electrical safety and regulatory compliance are paramount. The integrated cutout accommodates mechanical interlocking components, allowing for precise alignment and secure fastening between adjacent enclosures. This design feature eliminates the need for additional modifications or custom fabrication, reducing installation time and potential points of failure. Industries that benefit from the ProLine G2 Sequestr Barrier Panel include manufacturing plants, data centers, renewable energy facilities, and utility substations. In these settings, the panel helps mitigate risks associated with high-voltage equipment by creating a physical barrier that prevents accidental contact with live components. Its robust construction ensures long-term durability, even in harsh operating conditions such as extreme temperatures, humidity, or corrosive environments. Professionals in electrical engineering, panel building, and industrial automation rely on nVent’s ProLine G2 series for its reliability and adherence to industry standards like UL and IEC. Installation of the ProLine G2 Sequestr Barrier Panel is straightforward, thanks to its modular design and compatibility with standard enclosure systems. Electricians and technicians appreciate the panel’s pre-engineered cutouts and mounting features, which simplify alignment and reduce the need for on-site adjustments. The panel’s dimensions (1800x500mm) are optimized for common enclosure sizes, making it a versatile choice for retrofitting existing systems or designing new installations. Additionally, nVent’s reputation for quality and innovation ensures that this barrier panel meets the rigorous demands of industrial applications, providing peace of mind for engineers and facility managers alike. Choosing the right barrier panel is essential for maintaining safety, efficiency, and compliance in electrical enclosures. The nVent ProLine G2 Sequestr Barrier Panel stands out for its combination of durability, precision engineering, and ease of integration. Whether used in a new construction project or as part of an upgrade to an existing system, this panel delivers the performance and reliability required for critical infrastructure. Trusted by professionals worldwide, nVent continues to set the standard for electrical enclosure solutions, ensuring that installations are both safe and future-proof.
  • 16 gauge steel construction
  • RAL 7035 textured light-gray polyester powder paint finish
  • Cutouts for passage of mechanical interlocking components present, interlock components sold separately
  • Barrier panel serves as a joining kit between enclosures, no additional joining components are required
  • All mounting hardware is furnished with the Barrier Panel

Specifications

Application
Power Distribution; Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
70.87 x 19.69 in
Fits Frame
1800 x 500 mm
Insulation
No
Material
Mild Steel
Material
Steel
Mounting Type
Modular/Enclosure Integration
Product Family
ProLine
Series
ProLine G2
Series
ProLine G2 Sequestr
Size
70.2 x 18.1 x .79
Size
1800x500 mm
Thickness
16 ga
Thickness
1.52 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
37.9 lb
Package Dimensions (L x W x H)
73.7 IN x 21.57 IN x 1.88 IN
Package Dimensions (L x W x H)
187.198 cm x 54.7878 cm x 4.7752 cm
Package Weight (Imperial)
37.900 L
Package Weight (Metric)
17.191 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2CB145 Controller

This guide provides step-by-step instructions for installing and configuring the P2CB145 Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2CB145 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Using terminal connectors, connect the power supply wires to the designated terminals on the controller. Ensure that the connections are tight and secure.

  3. Verify electrical connections

    Use a multimeter to check the voltage at the power terminals. Confirm that the voltage is within the specified range for the P2CB145 controller.

  4. Configure initial settings

    Access the controller's configuration interface and set the initial parameters according to your system requirements. Save the settings.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure the controller operates accurately. Adjust settings as necessary.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.