The nVent ProLine G2 200-mm Plinth Bases (SKU: P2BP2168) are precision-engineered steel bases designed to elevate and support industrial enclosures while providing essential cable management infrastructure. These robust plinth bases install directly beneath enclosures measuring 1600x800mm, creating a secure foundation that enhances airflow, cable routing, and equipment protection in demanding industrial environments. Manufactured by nVent, a global leader in thermal management and electrical solutions, the ProLine G2 series delivers uncompromising durability with its black steel construction, ensuring long-term performance in harsh operating conditions. Primary Function and Design Benefits The core purpose of the ProLine G2 plinth base is to provide a stable, elevated platform for large industrial enclosures while facilitating clean, organized cable entry from below. Unlike standard floor-mounted solutions, these plinth bases create a dedicated space beneath the enclosure for cable routing, reducing clutter and minimizing the risk of damage from foot traffic or environmental contaminants. The 200-mm height offers optimal clearance for cable bend radii and thermal dissipation, while the steel construction ensures structural integrity under heavy loads. nVent’s engineering expertise is evident in the precision fitment for 1600x800mm enclosures, eliminating gaps and ensuring a seamless integration that maintains NEMA or IP-rated enclosure performance. Industry Applications and Use Cases ProLine G2 plinth bases are indispensable in industries where large electrical and control panels require elevated mounting for safety, accessibility, and compliance. Typical applications include manufacturing plants, data centers, utility substations, and commercial buildings where heavy-duty enclosures house critical control systems, motor starters, or power distribution units. In food and beverage processing facilities, the elevated design helps meet hygiene standards by preventing direct floor contact, while in chemical plants, the steel construction resists corrosion and chemical exposure. The plinth base also simplifies future maintenance by providing clear access to cables and components without dismantling the entire enclosure. Installation and Compatibility Considerations Installation of the ProLine G2 plinth base is straightforward, designed for quick alignment and secure anchoring to the floor. The base features pre-drilled mounting holes compatible with standard enclosure footprints, ensuring a precise fit for 1600x800mm units. Professionals should verify floor flatness and load-bearing capacity before installation, as the base distributes the enclosure’s weight across a larger surface area. For outdoor or high-moisture environments, additional sealing or protective coatings may be recommended to extend service life. nVent provides comprehensive installation guides and technical support to ensure optimal performance in any setting. Why Choose nVent ProLine G2 Plinth Bases? As part of the ProLine G2 family, these plinth bases benefit from nVent’s decades of expertise in thermal management and electrical infrastructure solutions. The company’s commitment to innovation is reflected in the robust design, which meets stringent industry standards for durability and safety. Whether for new installations or retrofitting existing systems, the ProLine G2 plinth base delivers a cost-effective solution that enhances enclosure performance, simplifies cable management, and supports long-term operational reliability. Trusted by engineers and facility managers worldwide, nVent’s products are engineered to withstand the rigors of industrial applications while maintaining compliance with global safety and performance regulations.
  • Four access panels for cable management options at the base of the enclosure
  • Sturdy cast aluminum corner supports for superior performance under load
  • Corner blocks can be installed onto the base of the frame independent of the cover plates, enabling the cover plates to be attached after integration and just prior to shipment
  • Stackable up to 400mm in height using Plinth Base Stacking Kit (not included)
  • 100 mm or 200 mm options
  • To maintain a NEMA Type 12 environmental rating, gland plate must also be used in the base of the enclosure
  • Installation hardware included
  • Cover plates are 16-gauge (1.5 mm) steel

Specifications

Application
Controls and Drives; Power Distribution
Color
Jet Black
Color
Black
Color Code
RAL 9005
Depth
31.08
Depth
764
Finish
Powder Coated
Fits Frame
1600x800 mm
Height
7.58
Height
193
Material
Steel
Material
Mild Steel
Product Family
ProLine
Series
ProLine G2
Size
200mm PLINTH 1600x800mm
Thickness
1.52 mm
Thickness
16 ga
Type
200mm
Weight
41 lb
Width
62.95
Width
1,599
Package Dimensions (L x W x H)
75 IN x 9 IN x 10 IN
Package Dimensions (L x W x H)
190.5 cm x 22.86 cm x 25.4 cm
Package Weight (Imperial)
41.000 L
Package Weight (Metric)
18.598 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2BP2168 Controller

This guide provides step-by-step instructions for installing and configuring the P2BP2168 Controller, ensuring proper wiring and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the P2BP2168 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Verify that the connections are secure and insulated.

  3. Configure initial settings

    Power on the controller and use the interface to navigate to the configuration menu. Set the required parameters according to your application needs.

  4. Calibrate the controller

    Follow the calibration procedure outlined in the manual to ensure accurate readings and performance. Use a multimeter to verify output signals.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.