nVent P2BGP88 - ProLine G2 Gland Plates, fits 800x800mm, Painted
nVent

P2BGP88

UPC: 783510310332


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Gland Plate (SKU: P2BGP88) is a premium, painted gland plate designed for 800x800mm enclosures, delivering robust cable management solutions with NEMA 12 protection. Engineered by nVent, a global leader in electrical and thermal management solutions, this gland plate combines durability with ergonomic design to enhance installation and maintenance workflows in industrial environments. The ProLine G2 series is specifically engineered to support heavy-duty applications, featuring the proprietary Duro-Stand Gland Plate that is engineered to bear the weight of a person—eliminating concerns about structural integrity during routine enclosure servicing or cable adjustments. Cable management is a critical component in modern industrial facilities, where downtime and safety are paramount. The ProLine G2 Gland Plate integrates seamlessly with nVent’s plinth base systems to provide a secure, organized entry point for cables into enclosures, preventing clutter and reducing the risk of damage or interference. Its NEMA 12 rating ensures protection against dust, dirt, and non-corrosive liquids, making it ideal for use in manufacturing plants, food processing facilities, water treatment centers, and other demanding environments where environmental ingress could compromise system reliability. Professionals in electrical engineering, automation, and facility management rely on gland plates like the ProLine G2 to maintain compliance with industry standards while optimizing operational efficiency. The painted finish not only enhances corrosion resistance but also improves visibility and aesthetics in cleanroom or controlled-environment applications. Installation is straightforward thanks to the gland plate’s precision-engineered fit, which aligns with standard enclosure dimensions and supports quick access for technicians. Whether used in new construction or retrofit projects, this gland plate delivers long-term performance with minimal maintenance. nVent’s reputation for innovation and quality is reflected in every aspect of the ProLine G2 Gland Plate. As part of the ProLine family of enclosure accessories, this product benefits from rigorous testing and adherence to global safety standards, ensuring compatibility with a wide range of industrial control panels, motor control centers, and automation systems. By choosing the ProLine G2, engineers and facility managers gain a reliable, high-strength solution that enhances both the functionality and longevity of their electrical infrastructure—ultimately reducing total cost of ownership and improving system uptime.
  • Consists of a base mounting surface and adjustable foam gasketed gland plates that permit cable entry
  • Sturdy, adjustable gland plates designed to bear the weight of a person
  • Number of plates varies with depth: 400 mm and 500 mm (3 plates); 600 mm (4 plates); 800 mm (6 plates); 1000 mm (8 plates)
  • Galvanized or painted versions
  • Sealed to maintain NEMA Type 12 rating
  • Gland Plates are finished with paint over plated surfaces
  • Can be used with Plinth Base (100 mm or 200 mm), 100 mm Solid Plinth Base, Mobile Base or Transportation Base
  • Can be used without a base if casters, levelers or frame feet are installed
  • Can be rotated 180 degrees for front or rear cable entry
  • Installation hardware included

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color
Painted
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
800x800 mm
Gland Plate Quantity
6
Material
Steel
Material
Mild Steel
Material
Metal
Nema Rating
Type 12
Nema Rating
NEMA 12
Product Family
ProLine
Series
ProLine G2
Size
800x800mm
Thickness
1.9 mm
Thickness
14 ga
Type
External Mounting for ProLine Industrial Enclosures
Weight
37 lb
Package Dimensions (L x W x H)
35.5 IN x 34.25 IN x 4 IN
Package Dimensions (L x W x H)
90.17 cm x 86.995 cm x 10.16 cm
Package Weight (Imperial)
37.000 L
Package Weight (Metric)
16.783 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2K1688 Controller

This guide provides step-by-step instructions for installing and configuring the P2K1688 Controller for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2K1688 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Use wire strippers to prepare the power supply wires and connect them to the appropriate terminals on the controller. Ensure the connections are tight and secure.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. If the voltage is incorrect, double-check your connections.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters for your application. Save the settings before exiting.

  5. Calibrate the controller

    Follow the calibration procedure as outlined in the user manual to ensure the controller operates within the desired specifications.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.