nVent P2BGP68 - ProLine G2 Gland Plates, fits 600x800mm, Painted
nVent

P2BGP68

UPC: 783510310219


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Gland Plate (SKU: P2BGP68) is a robust and intelligently designed solution for superior cable management and enclosure integrity. Engineered to fit 600x800mm enclosures, this painted gland plate seamlessly integrates with plinth bases to offer a comprehensive cable entry system. Its primary function is to provide a secure and organized pathway for electrical and data cables entering an industrial enclosure, while crucially maintaining the enclosure's environmental protection rating, such as NEMA 12. What sets the ProLine G2 Gland Plate apart is its innovative Duro-Stand feature. This unique design allows the gland plate to bear the weight of a person, transforming it into a practical work platform. This significantly enhances safety and convenience for technicians and engineers who need to access or service the enclosure's internal components. The ability to safely stand on the installed gland plate streamlines maintenance tasks, reduces the need for additional scaffolding or ladders in many scenarios, and ultimately improves operational efficiency. Crafted by nVent, a globally recognized leader in electrical connection and protection solutions, the ProLine G2 Gland Plate embodies their commitment to quality, durability, and user-centric design. The painted finish provides an additional layer of protection against corrosion and environmental factors, ensuring long-term performance in demanding industrial settings. This product is essential for applications requiring meticulous cable organization, protection against dust and water ingress, and enhanced accessibility for maintenance. Key benefits and features include: * **Superior Cable Management:** Facilitates organized and secure cable entry, preventing strain and damage. * **Maintained Enclosure Rating:** Ensures the integrity of NEMA 12 and other environmental protection standards. * **Duro-Stand Innovation:** Designed to support the weight of a person, acting as a safe work platform. * **Enhanced Accessibility:** Simplifies enclosure maintenance and servicing. * **Durable Construction:** Built with high-quality materials for long-lasting performance. * **Seamless Integration:** Designed to fit 600x800mm enclosures and work with plinth bases. This gland plate is an indispensable component for a wide array of industries, including manufacturing, automation, power distribution, and telecommunications, where reliable and safe cable management is paramount. By choosing the nVent ProLine G2 Gland Plate, you are investing in a solution that not only meets stringent industrial requirements but also enhances the safety and productivity of your operations. The UNSPSC code for this product is 39121334, and it is proudly manufactured in the US.
  • Consists of a base mounting surface and adjustable foam gasketed gland plates that permit cable entry
  • Sturdy, adjustable gland plates designed to bear the weight of a person
  • Number of plates varies with depth: 400 mm and 500 mm (3 plates); 600 mm (4 plates); 800 mm (6 plates); 1000 mm (8 plates)
  • Galvanized or painted versions
  • Sealed to maintain NEMA Type 12 rating
  • Gland Plates are finished with paint over plated surfaces
  • Can be used with Plinth Base (100 mm or 200 mm), 100 mm Solid Plinth Base, Mobile Base or Transportation Base
  • Can be used without a base if casters, levelers or frame feet are installed
  • Can be rotated 180 degrees for front or rear cable entry
  • Installation hardware included

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
600x800 mm
Gland Plate Quantity
6
Material
Mild Steel
Product Family
ProLine
Thickness
14 ga
Thickness
1.9 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
26 lb
Package Dimensions (L x W x H)
34 IN x 27 IN x 4 IN
Package Dimensions (L x W x H)
86.36 cm x 68.58 cm x 10.16 cm
Package Weight (Imperial)
26.000 L
Package Weight (Metric)
11.794 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2K1688 Controller

This guide provides step-by-step instructions for installing and configuring the P2K1688 Controller for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2K1688 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Use wire strippers to prepare the power supply wires and connect them to the appropriate terminals on the controller. Ensure the connections are tight and secure.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. If the voltage is incorrect, double-check your connections.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters for your application. Save the settings before exiting.

  5. Calibrate the controller

    Follow the calibration procedure as outlined in the user manual to ensure the controller operates within the desired specifications.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.