nVent P2BGP46G - ProLine G2 Gland Plates, fits 400x600mm, Galvanized
nVent

P2BGP46G

UPC: 783510310080


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Gland Plate, SKU P2BGP46G, is a robust and intelligently designed component essential for comprehensive cable management within industrial enclosures. Crafted from high-quality galvanized steel, this gland plate is specifically engineered to fit 400x600mm enclosures, providing a secure and organized interface for routing power and data cables. Its primary function is to facilitate the efficient and safe entry and exit of cables while maintaining the integrity of the enclosure's environmental protection, particularly crucial for achieving and sustaining NEMA 12 ratings. This ensures that sensitive internal components remain shielded from dust, dirt, and falling liquid or dripping water. Beyond basic cable entry, the ProLine G2 series introduces innovative features that enhance usability and safety in demanding industrial environments. A standout innovation is the Duro-Stand Gland Plate design. This unique feature allows the gland plate to bear significant weight, including the weight of a person. This is a critical advantage during installation and maintenance, as it provides a stable platform for technicians to stand on or lean against while working on the enclosure. This enhanced load-bearing capacity not only improves safety but also significantly streamlines maintenance procedures, reducing downtime and increasing operational efficiency. When selecting a gland plate, professionals consider factors such as enclosure dimensions, required cable density, environmental sealing needs, and ease of installation. The nVent ProLine G2 Gland Plate excels in these areas. Its precise fit for 400x600mm enclosures minimizes gaps and ensures a tight seal when properly installed. The galvanized finish offers excellent corrosion resistance, making it suitable for a wide range of industrial settings, including manufacturing plants, processing facilities, and outdoor applications where exposure to moisture and corrosive elements is a concern. The UNSPSC code 39121334 categorizes this product within electrical equipment and accessories, highlighting its role in electrical infrastructure. Installation of the ProLine G2 Gland Plate is designed for efficiency. It typically integrates seamlessly with plinth bases, forming a complete cable management and enclosure support system. This integrated approach simplifies the setup process and ensures a secure foundation for the enclosure. nVent, a trusted leader in electrical solutions, brings its extensive engineering expertise to the ProLine G2 series, guaranteeing reliability and performance. The US country of origin further underscores a commitment to quality manufacturing standards. For applications demanding superior cable management, enhanced worker safety, and durable environmental protection, the nVent ProLine G2 Gland Plate is an indispensable component.
  • Consists of a base mounting surface and adjustable foam gasketed gland plates that permit cable entry
  • Sturdy, adjustable gland plates designed to bear the weight of a person
  • Number of plates varies with depth: 400 mm and 500 mm (3 plates); 600 mm (4 plates); 800 mm (6 plates); 1000 mm (8 plates)
  • Galvanized or painted versions
  • Sealed to maintain NEMA Type 12 rating
  • Gland Plates are finished with paint over plated surfaces
  • Can be used with Plinth Base (100 mm or 200 mm), 100 mm Solid Plinth Base, Mobile Base or Transportation Base
  • Can be used without a base if casters, levelers or frame feet are installed
  • Can be rotated 180 degrees for front or rear cable entry
  • Installation hardware included

Specifications

Application
Power Distribution; Controls and Drives
Color
Unpainted
Finish
Galvanized
Fits Frame
400x600 mm
Gland Plate Quantity
4
Material
Mild Steel
Product Family
ProLine
Thickness
14 ga
Thickness
1.9 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
14 lb
Package Dimensions (L x W x H)
26 IN x 19 IN x 3.5 IN
Package Dimensions (L x W x H)
66.04 cm x 48.26 cm x 8.89 cm
Package Weight (Imperial)
14.000 L
Package Weight (Metric)
6.350 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2BGP46G Controller

This guide provides step-by-step instructions for installing and configuring the P2BGP46G Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2BGP46G Controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Using terminal connectors, connect the power supply wires to the designated terminals on the controller. Verify that the connections are secure and polarity is correct.

  3. Configure the controller settings

    Power on the controller and access the configuration menu. Set the required parameters according to your application needs and save the settings.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.