nVent P2BGP108 - ProLine G2 Gland Plates, fits 1000x800mm, Painted
nVent

P2BGP108

UPC: 783510309770


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine G2 Gland Plate (SKU: P2BGP108) is a premium-grade cable management solution engineered for heavy-duty industrial enclosures. Designed to fit 1000x800mm plinth bases, this painted gland plate delivers robust protection while maintaining a NEMA 12 rating, ensuring resistance to dust, dirt, and non-corrosive liquids. Part of the ProLine G2 series, this component is built to withstand the demands of harsh industrial environments, providing reliable performance in manufacturing plants, data centers, utilities, and commercial facilities where cable organization and equipment protection are critical. Key features of the ProLine G2 Gland Plate include its durable construction and the innovative Duro-Stand design, which is engineered to support the weight of a person. This ergonomic advantage simplifies maintenance and installation tasks, allowing technicians to safely access and service the enclosure without compromising structural integrity. The painted finish enhances corrosion resistance and provides a professional appearance, making it ideal for applications where aesthetics and durability are equally important. Industries that benefit from the ProLine G2 Gland Plate include oil and gas, chemical processing, food and beverage, pharmaceuticals, and renewable energy. In these sectors, maintaining a clean and organized cable infrastructure is essential for operational efficiency and compliance with safety standards. The NEMA 12 rating ensures the gland plate meets stringent requirements for indoor use, protecting sensitive equipment from environmental contaminants. Installation is straightforward with the ProLine G2 Gland Plate, as it is designed to integrate seamlessly with nVent’s ProLine G2 plinth bases. Professionals in electrical and mechanical engineering fields trust nVent for its commitment to innovation and quality, as evidenced by the ProLine G2 series’ reputation for reliability and performance. Whether used in new installations or retrofits, this gland plate provides a cost-effective solution for cable management that enhances both functionality and safety. Choose the nVent ProLine G2 Gland Plate (P2BGP108) for a durable, high-performance component that meets the demands of modern industrial applications. With its robust construction, NEMA 12 rating, and ergonomic design, it is the ideal choice for professionals seeking a reliable cable management solution.
  • Consists of a base mounting surface and adjustable foam gasketed gland plates that permit cable entry
  • Sturdy, adjustable gland plates designed to bear the weight of a person
  • Number of plates varies with depth: 400 mm and 500 mm (3 plates); 600 mm (4 plates); 800 mm (6 plates); 1000 mm (8 plates)
  • Galvanized or painted versions
  • Sealed to maintain NEMA Type 12 rating
  • Gland Plates are finished with paint over plated surfaces
  • Can be used with Plinth Base (100 mm or 200 mm), 100 mm Solid Plinth Base, Mobile Base or Transportation Base
  • Can be used without a base if casters, levelers or frame feet are installed
  • Can be rotated 180 degrees for front or rear cable entry
  • Installation hardware included

Specifications

Application
Power Distribution; Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Finish
Powder Coated
Fits Frame
1000X800 mm
Gland Plate Quantity
6
Material
Mild Steel
Product Family
ProLine
Thickness
14 ga
Thickness
1.9 mm
Type
External Mounting for ProLine Industrial Enclosures
Weight
42 lb
Package Dimensions (L x W x H)
43 IN x 33 IN x 4 IN
Package Dimensions (L x W x H)
109.22 cm x 83.82 cm x 10.16 cm
Package Weight (Imperial)
42.000 L
Package Weight (Metric)
19.051 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the P2BGP108 Controller

This guide provides step-by-step instructions for installing and configuring the P2BGP108 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2BGP108 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power supply and input/output wires to the appropriate terminals on the controller. Follow the wiring diagram provided in the documentation.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure proper connection. Confirm that all connections are secure and correct.

  4. Configure the controller

    Access the controller's configuration interface via a web browser or dedicated software. Input the necessary settings as per your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the documentation to ensure the controller operates within specified parameters.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.