Contact for Pricing
Overview
- 18-inch fluorescent enclosure light for industrial applications
- 120 VAC, 50/60 Hz operation
- Flexible wiring with pre-wired sockets and optional terminal blocks (up to 16 AWG)
- Daisy-chain up to five lights with optional ganging cables
- Durable construction with extruded aluminum center support and composite end caps
- Black composite end caps and mounting tabs
- Mounting hardware is included
Specifications
Application | Controls and Drives; Power Distribution |
Color | Gray |
Color | Black |
Connection Type | Plug-and-play or Terminal Blocks |
Material | Aluminum |
Mounting Type | Mounting tabs |
Series | PaneLite Fluorescent |
Size | 18-in |
Type | Electrical Accessories |
Voltage Rating | 120V |
Package Dimensions (L x W x H) | 20.1 IN x 4.7 IN x 2.5 IN |
Package Dimensions (L x W x H) | 51.054 cm x 11.938 cm x 6.35 cm |
Package Weight (Imperial) | 1.800 L |
Package Weight (Metric) | 0.817 kg |

ALF15M18
Light Pkg.Fluorescent, Man Sw, Bulletin A80LT (Light kits - Lighting Packages), Size/Dims: 18.88x 115v/50Hz, Material: Aluminum, Finish:
ALF16M18
Light Pkg.Fluorescent, Man Sw, Bulletin A80LT (Light kits - Lighting Packages), Size/Dims: 18.88x 115v/60Hz, Material: Aluminum, Finish:
ALF16M48
Light Pkg.Fluorescent, Man Sw, Bulletin A80LT (Light kits - Lighting Packages), Size/Dims: 48.88x 115v/60Hz, Material: Aluminum, Finish:
ALF16D24
Light Pkg. Fluorescent, Dr Sw, Bulletin A80LT (Light kits - Lighting Packages), Size/Dims: 24.88x 115v/60Hz, Material: Aluminum, Finish:
ALF16D18
Light Pkg. Fluorescent, Dr Sw, Bulletin A80LT (Light kits - Lighting Packages), Size/Dims: 18.88x 115v/60Hz, Material: Aluminum, Finish:How to Install the LF120V18 Fluorescent Lighting Package
This guide provides step-by-step instructions for safely installing and wiring the LF120V18 fluorescent lighting package within an enclosure. Ensure all safety warnings are followed to prevent electric shock and equipment damage.
Estimated time: 30m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting hardware, Wire connectors
- Read Instructions and Safety Warnings
Before beginning any installation, carefully read all instructions provided in the manual. Pay close attention to all WARNING and AVERTISSEMENT sections to understand potential hazards and necessary precautions. Ensure the fluorescent lighting package is suitable for your environment and power supply.
- Disconnect Power Supply
To avoid electric shock and equipment damage, disconnect all power supplies to the enclosure where the light will be installed. Verify that power is completely off using a multimeter or appropriate testing device before proceeding.
- Mount the Fluorescent Fixture
Securely mount the fluorescent lighting fixture inside the enclosure using appropriate mounting hardware. Refer to the specific mounting diagrams (e.g., PROLINE Frame, Enclosure Top, Enclosure Channel, Optional Panel) for your application. Ensure the fixture is firmly attached and stable.
- Connect Power Supply Wires
Connect the fluorescent fixture to a single-phase power supply that is consistent with the voltage and frequency information found on the product label. Route supply wires away from door hinges, sharp edges, and other potential pinch points. Power must be connected to the switch end of the light. All wiring must comply with applicable national and local electrical codes.
- Ground the Fluorescent Fixture
Ensure the fluorescent fixture's ground terminal is properly connected to a reliable earth ground source. A proper ground connection is crucial for safe operation and to prevent intermittent operation. Verify the integrity of the ground connection.
- Verify Clearances and Energize
Before energizing any circuits, check all internal and external electrical and mechanical clearances to ensure that all assembled equipment functions safely and properly. Once clearances are verified, restore power to the enclosure and test the fluorescent lighting package for correct operation.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.