Contact for Pricing
Overview
- 73x107x19mm broadband crystal optic window for thermal imaging
- IP65 rated for protection against water and dust ingress
- Arc flash tested to 50kA for 1 second at 11kV
- HYDROGARD™ lens moisture protection for outdoor use
- Spring-loaded cover with quarter-turn locking system for quick access
- Quick access via spring-loaded cover and quarter-turn locking system.
- Includes drilling template, hardware, and instructions for easy installation.
Specifications
Material | Aluminum |
Mounting Type | Self-adhesive drilling template |
Series | IR Window |
Size | 73x107x19mm |
Package Dimensions (L x W x H) | 4.05 IN x 2.9 IN x 0.77 IN |
Package Dimensions (L x W x H) | 10.287 cm x 7.366 cm x 1.9558 cm |
Package Weight (Imperial) | 1.000 L |
Package Weight (Metric) | 0.454 kg |

TC150
Universal raintight hubs are rated for outdoor enclosures and come in a variety of sizes for every ABB load center or panel. The TC150 has a diameter of 1.50" and has a base size of 3".
F385-G
PVC Coated F Service Head, Threaded Rigid, Conduit Size 1 Inch, Number and Diameter of Knockouts Two at 7/16 Inch, Three at 1/2 Inch, Aluminum,GrayHow to Install the IW4000 Infrared Window
This guide provides step-by-step instructions for installing the IW4000 Infrared Window onto a flat surface of a type 4/12 enclosure, including drilling and mounting procedures. Comply with local and national safety requirements when working in hazardous locations.
Estimated time: 45m
Tools needed:
Hydraulic punch or hole saw (95 mm - 95.5 mm (3-3/4 in.)), Drill, Conedrill, Pozidrive screwdriver, Center punch, 6 mm (1/4 in.) drill bit, 3.6 mm (9/64 in.) drill bit
Supplies needed:
IW4000 unit, Fixing screws (4), Drilling template, Degreaser
- Unpack and Inspect Components
Carefully unpack the IW4000 unit and verify all contents are present: one IW4000 unit, four fixing screws, and one drilling template.
- Prepare Mounting Surface
Confirm the desired position for the IW4000 unit on a flat surface of a type 4/12 enclosure. Peel off the backing from the drilling template and firmly stick it to the panel, aligning with the template reference points.
- Mark and Drill Pilot Holes
Using a center punch, mark the positions for the fixing holes and the center hole as indicated on the template. Then, use a 6 mm (1/4 in.) twist drill to drill out the center pilot hole.
- Drill Fixing Holes
Using a 3.6 mm (9/64 in.) twist drill, carefully drill out the four fixing holes marked on the template.
- Enlarge Center Hole
Enlarge the center hole to 95-95.5 mm (3-3/4 in.) using either a hole saw (guiding with the 6 mm pilot hole) or a hydraulic punch. If using a hydraulic punch, refer to its manual and follow all safety procedures.
- Clean and Prepare Panel
De-burr all drilled holes, remove any metal shavings, and peel off the self-adhesive drilling template. Thoroughly degrease the front panel surface where the window will be mounted.
- Mount the Infrared Window
Align the fixing holes on the IW4000 unit with the drilled holes on the panel and firmly press the Infrared Window into place.
- Secure the Window
Using a Pozidrive screwdriver and three of the four supplied countersunk screws, gradually tighten each screw in an alternating pattern. Advance each fixing until a torque setting between 0.5 – 1 lbf.ft (0.68 – 1.36 N.m) is achieved, ensuring the unit is securely fastened. To maintain the enclosure type rating, ensure the viewport cover is secured in place.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.