nVent ECFA300 - Earthing Cables, ECFA, 13x381x8mm, 300mm Length
nVent

ECFA300

UPC: 783510473686


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ECFA300 is a specialized floor sensing probe designed to work with nVent electric floor heating controls. Its primary function is to prevent floor overheating, ensuring safe and efficient operation of your radiant floor heating system. Manufactured by nVent, this sensor features a thin, flexible probe with a diameter of 4.5 mm and an overall length of 120 mm, making installation straightforward within floor assemblies. The generous 12 ft (3.7 m) lead length provides ample reach for connection to compatible thermostats. The ECFA300 accurately measures floor temperature within a range of 10°F to 90°F (-12°C to 32°C). It operates reliably within an ambient temperature range of 32°F to 122°F (0°C to 50°C) and has a storage temperature range of -4°F to 158°F (-20°C to 70°C). This sensor is UL Listed for both Canada and the US, and CSA Certified, attesting to its safety and quality standards. It is compatible with several nVent thermostat models, including the TH112, TH130, TH140-111, and TH142-111, offering flexibility in system design. SKU: ECFA300. Country of Origin: US.
  • Floor sensing probe for nVent electric floor heating controls
  • Prevents floor overheating for safe operation
  • Thin, flexible 4.5mm diameter probe, 120mm length
  • 12 ft (3.7 m) lead length for flexible installation
  • Temperature sensing range: 10°F to 90°F (-12°C to 32°C)
  • UL Listed (Canada and US) and CSA Certified

Specifications

Application
Controls and Drives; Factory Automation and Process Control
Application
Power Distribution; Controls and Drives; Factory Automation and Process Control
Bolt Size
M8
Cable Diameter
0.31 in
Cable Diameter
8 mm
Color
Yellow Green
Connection Type
M8 to M8
Connection Type
M8
Consist of
Earthing Cables; Mounting Components and Instruction Manual
Depth
0.31 in
Depth
8 mm
Enclosure Material
Mild Steel
Finish
Smooth Matte
Height
13 mm
Height
0.51 in
Length
11.81 in
Length
300 mm
Material
Tinned Electrolytic Copper
Material
Copper
Package Quantity
10
Product Family
Free-Standing
Series
ECFA
Size
13x381x8mm
Size
0.51 x 15 x 0.31 inch
Size
13x381x8mm, 300mm Length
Type
IEC Enclosure Accessories
Type
Earthing
Weight
1 lb
Weight
0.5 kg
Width
15 in
Width
381 mm
Works With
IEC
Package Dimensions (L x W x H)
12 IN x 6 IN x 6 IN
Package Dimensions (L x W x H)
30.48 cm x 15.24 cm x 15.24 cm
Package Weight (Imperial)
1.000 L
Package Weight (Metric)
0.454 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the ECFA300 Controller

This guide provides step-by-step instructions for mounting, wiring, and configuring the ECFA300 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the ECFA300 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power supply and input/output wires to the appropriate terminals on the ECFA300. Follow the wiring diagram provided in the documentation.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure proper connection. Confirm that all connections are secure and correctly wired.

  4. Configure the controller

    Access the configuration interface of the ECFA300 and input the necessary parameters as per your application requirements. Save the settings.

  5. Calibrate the system

    Perform calibration by following the calibration procedure outlined in the user manual. Adjust settings as needed to ensure optimal performance.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.