Contact for Pricing
Overview
- Drawn enclosure
- No welded seams or sharp corners
- Removable door with unique lift-off hinges
- Oil-tight quarter-turn slotted latches
- Oil-resistant gasket
- Weldnuts provided for mounting optional panels
- Bonding provision on door
Specifications
Application | Controls and Drives |
Color | Gray |
Color Code | ANSI 61 |
Conductive Panel | A6P6G |
Depth | 13 IN |
Depth | 6 in |
Depth, Maximum | 6 |
Depth, Minimum | 6 |
Finish | Powder Coated |
Height | 44 IN |
Height | 6 IN |
IP Rating | IP55 |
Ip Rating | IP55/IP66 |
Ip Rating | IP54/IP66 |
Material | Mild Steel;Steel |
Material | Steel |
Modification Services | Yes |
Mounting Type | Wall/Panel Mounting |
Mounting Type | external welded mounting brackets |
Mounting Type | External welded mounting brackets, Internal threaded weld studs |
NEMA Rating | 12 |
Nema Rating | Type 12 |
Overall Dimensions | 114 x 88 mm |
Overall Dimensions | 6.09 x 6.45 in |
Panel | A6P6 |
Panel Size | 4.88 x 4.88 in |
Panel Size | 72.00 x 72.00 in |
Protection Rating | NEMA Type 12 |
Series | nVent D666IS |
Series | D666IS |
Size | 6x6x6 |
Size | 6.00x6.00x6.00 |
Size | 6.00x6.00x6.00 in |
Size | 6x6x6 inches |
Thickness | 16 ga |
Thickness | 51.40mm (2.024") |
Type | Mild Steel Terminal and Junction Boxes |
Type | Mild Steel Industrial Terminal and Junction Boxes |
Type Number | Type 12 |
Weight | 4 lb |
Width | 152 mm |
Width | 6 IN |
Package Dimensions (L x W x H) | 6.75 IN x 6.25 IN x 7.5 IN |
Package Dimensions (L x W x H) | 17.145 cm x 15.875 cm x 19.05 cm |
Package Weight (Imperial) | 4.000 L |
Package Weight (Metric) | 1.814 kg |
Frequently Asked Questions
What industry standards does the nVent D666IS enclosure meet?
The nVent D666IS enclosure meets UL 508A Listed (Type 12), cUL Listed (Type 12), NEMA/EEMAC Type 12, and IEC 60529 IP55 standards.
What is the construction material and gauge of the D666IS enclosure?
The nVent D666IS enclosure is constructed from drawn 16 gauge steel.
What type of latch mechanism does the D666IS enclosure use?
The nVent D666IS enclosure features oil-tight quarter-turn slotted latches.
What is the finish of the nVent D666IS enclosure?
The nVent D666IS enclosure has an ANSI 61 gray polyester powder paint finish, applied inside and out.
Can panels be mounted inside the D666IS enclosure?
Yes, weldnuts are provided within the nVent D666IS enclosure for mounting optional panels.
What are the dimensions of the nVent D666IS enclosure?
The nVent D666IS enclosure has external dimensions of 6x6x6 inches (152x152x152 mm).
Does the D666IS enclosure have a gasket for sealing?
Yes, the nVent D666IS enclosure is equipped with an oil-resistant gasket for sealing.
How to Install the Grounding Kit for E9PBY25M
This guide provides step-by-step instructions for installing the grounding kit for the E9PBY25M, ensuring proper electrical continuity and safety.
Estimated time: 15m
Tools needed:
Screwdriver, Torque wrench
Supplies needed:
10-32x5/8 screws, Keps nuts, 10-32 hex nuts, Lockwashers, Ground wire, Grounding label
- Insert the mounting screw
Insert the 10-32x5/8 screw through the designated hole in the panel.
- Secure the screw
Tighten the screw using a keps nut, ensuring that the nut penetrates into the paint for proper electrical continuity.
- Attach the ground wire
Connect the ground wire and secure it using a 10-32 hex nut.
- Install the lockwasher
Place a lockwasher under one of the screws securing the panel to ensure grounding between the panel and the enclosure. Do not exceed a torque of 30 in-lbs.
- Apply the grounding label
Attach the included grounding label adjacent to the bolt as indicated in the installation instructions.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.