Overview

The nVent CT66PTFCSS 90-degree perforated tee top cover is a stainless steel (SS304) component designed for 6.00x6.00 inch CleanTray cable management systems. This brushed finish cover features uniform perforations for enhanced ventilation and heat dissipation, which helps extend cable lifespan in demanding washdown environments. It enables right-angle transitions where two 90-degree turns are required, integrating seamlessly with CleanTray systems for continuous cable routing. The SS304 construction provides superior corrosion resistance, making it ideal for use in chemical plants, food and beverage facilities, and pharmaceutical manufacturing where hygiene and durability are critical. The perforated design allows for easy cable tie integration, ensuring secure and organized cable management without restricting airflow. The catalog number CT66PTFCSS matches 152x152 mm (6x6 in) tray dimensions with a sloped front cover, providing a clean aesthetic while maintaining functionality. UNSPSC code 39131716.
  • Clean Tray 90-Degree Tees are used for right-angle installations where two 90-degree transitions are required
  • The Clean Tray stainless steel system is designed to protect rated cabling in applications that require frequent washdown
  • Perforated design enables ventilation and heat dissipation for cable longevity
  • Sloped front cover with 11.00 in (279 mm) width and 16.00 in (406 mm) depth
  • Integrates with CleanTray systems for right-angle cable transitions

Specifications

Application
Corrosive Environments; Power Distribution; Hygienic Environments
Color
Unpainted
Finish
Brushed #3
Height
6 IN
Height
152 mm
Material
Stainless Steel
Modification Services
Yes
Product Family
CleanTray
Thickness
18 ga
Thickness
1.27 mm
Type
Tee
Type
Industrial Lay-in Wireway
Weight
8.7 lb
Width
6 IN
Width
152 mm
Wireway
Clean Tray Stainless Steel Cable Tray
Package Dimensions (L x W x H)
20.3 IN x 14.3 IN x 7.4 IN
Package Dimensions (L x W x H)
51.562 cm x 36.322 cm x 18.796 cm
Package Weight (Imperial)
8.700 L
Package Weight (Metric)
3.946 kg
90-Degree Elbow CleanTray Inside Cover Sloped, 6.00x6.00, Brushed, SS304

CTS66EIC90SS

90-Degree Elbow CleanTray Inside Cover Sloped, 6.00x6.00, Brushed, SS304
90-Degree Elbow CT Top Cover Sloped Inward no Tabs, 6.00x6.00, Brushed, SS304

CTS66EFCNT90SS

90-Degree Elbow CT Top Cover Sloped Inward no Tabs, 6.00x6.00, Brushed, SS304
45-Deg Elbow Top Cover CleanTray, 6.00x6.00, Brushed, SS304

CT66EFC45SS

45-Deg Elbow Top Cover CleanTray, 6.00x6.00, Brushed, SS304
90-Degree Tee CleanTray Top Cover, 4.00x6.00, Brushed, SS304

CT46TFCSS

90-Degree Tee CleanTray Top Cover, 4.00x6.00, Brushed, SS304
Divider Straight Section CleanTray, 6.00x6.00, Brushed, SS304

CT66DSS

Divider Straight Section CleanTray, 6.00x6.00, Brushed, SS304
90-Degree Tee CleanTray Top Cover Sloped, 6.00x6.00, Brushed, SS304

CTS66TFCSS

90-Degree Tee CleanTray Top Cover Sloped, 6.00x6.00, Brushed, SS304
90-Degree Tee CleanTray Top Cover Sloped Perforated, 6.00x6.00, Brushed, SS304

CTS66PTFCSS

90-Degree Tee CleanTray Top Cover Sloped Perforated, 6.00x6.00, Brushed, SS304
90-Degree Tee CleanTray Top Cover Sloped Perforated, 4.00x6.00, Brushed, SS304

CTS46PTFCSS

90-Degree Tee CleanTray Top Cover Sloped Perforated, 4.00x6.00, Brushed, SS304
90-Degree Elbow CT Top Cover Sloped Outward no Tabs, 4.00x6.00, Brushed, SS304

CTS46EFCONT90SS

90-Degree Elbow CT Top Cover Sloped Outward no Tabs, 4.00x6.00, Brushed, SS304
90-Degree Elbow CleanTray Perforated without Tabs, 4.00x6.00, Brushed, SS304

CT46PEFCNT90SS

90-Degree Elbow CleanTray Perforated without Tabs, 4.00x6.00, Brushed, SS304
Divider Straight Section CleanTray, 4.00x4.00, Brushed, SS304

CT44DSS

Divider Straight Section CleanTray, 4.00x4.00, Brushed, SS304
45-Deg Elbow Outside Cover CleanTray, 4.00x6.00, Brushed, SS304

CT46EOC45SS

45-Deg Elbow Outside Cover CleanTray, 4.00x6.00, Brushed, SS304

How to Install the CT46EIC45SS Controller

This guide provides step-by-step instructions for installing and configuring the CT46EIC45SS controller, ensuring proper wiring and setup for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the CT46EIC45SS controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the controller's power terminals. Ensure the connections are tight and insulated to prevent short circuits.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals of the controller. Ensure the voltage matches the specifications outlined in the user manual.

  4. Configure initial settings

    Power on the controller and access the configuration menu. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure in the user manual to ensure the controller operates accurately. Adjust settings as necessary based on the calibration results.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.