nVent CT44DEFC90SS - Divider 90-Degree Elbow CleanTray Top Cover, 4.00x4.00, Brushed, SS304
nVent

CT44DEFC90SS

UPC: 783510161187


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent CT44DEFC90SS is a specialized front cover designed for the nVent Clean Tray stainless steel cable management system. This component, constructed from durable SS304 brushed stainless steel, is engineered to divide a 4.00 x 4.00 inch (102 x 102 mm) 90-degree elbow into two distinct sections. Its primary function is to maintain cable separation and organization within the elbow transition, crucial for protecting rated cabling in environments requiring frequent washdowns and stringent hygiene standards, such as food and beverage processing and pharmaceutical manufacturing. The nVent Clean Tray system offers robust construction suitable for critical applications. The CT44DEFC90SS integrates with other Clean Tray components to form a complete, secure, and maintainable cable pathway. Key features include superior SS304 brushed stainless steel for corrosion resistance, precise fit for 4x4 inch cable tray sizes, effective division of 90-degree elbows, and suitability for washdown procedures. Manufactured by nVent, this front cover ensures quality and performance for sensitive industrial areas. The brushed finish also reduces glare. SKU: CT44DEFC90SS.
  • Clean Tray 90-Degree Elbow Dividers are used For dividing a Clean Tray 90-degree elbow into two sections
  • The Clean Tray stainless steel system is designed to protect rated cabling in applications that require frequent washdown
  • Divides 90-degree elbows into two sections
  • Ideal for washdown and hygienic applications
  • Enhances cable organization and protection

Specifications

Application
Corrosive Environments; Power Distribution; Hygienic Environments
Color
Unpainted
Color
Brushed
Finish
Brushed #3
Fits Cable Tray Size
4 x 4 in
Height
4 IN
Height
102 mm
Material
Stainless Steel
Material
SS304
Modification Services
Yes
NEMA Rating
1 Indoor, electrical protection
Product Family
CleanTray
Protection Rating
NEMA Type 1
Series
CleanTray
Size
4.00 x 4.00 inch (102 x 102 mm)
Thickness
1.27 mm
Thickness
18 ga
Type
Divider
Type
Industrial Lay-in Wireway
Weight
0.8 lb
Width
4 IN
Width
102 mm
Wireway
Clean Tray Stainless Steel Cable Tray
Package Dimensions (L x W x H)
10.4 IN x 5.6 IN x 5.5 IN
Package Dimensions (L x W x H)
26.416 cm x 14.224 cm x 13.97 cm
Package Weight (Imperial)
0.800 L
Package Weight (Metric)
0.363 kg
Enclosure Adapter CleanTray, 4.00x4.00, Brushed, SS304

CT44AESS

Enclosure Adapter CleanTray, 4.00x4.00, Brushed, SS304
Divider CleanTray 90-Degree Tee Outside Cover, 4.00x4.00, Brushed, SS304

CT44DTOCSS

Divider CleanTray 90-Degree Tee Outside Cover, 4.00x4.00, Brushed, SS304
U-Connector CleanTray, 4.00x4.00, Brushed, SS304

CT44UCSS

U-Connector CleanTray, 4.00x4.00, Brushed, SS304
Side Coupling CleanTray, 4.00x4.00, Brushed, SS304

CT44SCSS

Side Coupling CleanTray, 4.00x4.00, Brushed, SS304
Divider CleanTray 90-Degree Tee, 4.00x4.00, Brushed, SS304

CT44DTICSS

Divider CleanTray 90-Degree Tee, 4.00x4.00, Brushed, SS304
Divider 90-Degree Elbow CleanTray Outside Cover, 4.00x4.00, Brushed, SS304

CT44DEOC90SS

Divider 90-Degree Elbow CleanTray Outside Cover, 4.00x4.00, Brushed, SS304
Reducer CleanTray, 4x4 to 3x3, Brushed, SS304

CT4433RSS

Reducer CleanTray, 4x4 to 3x3, Brushed, SS304
Reducer CleanTray, 4x4 to 2x2, Brushed, SS304

CT4422RSS

Reducer CleanTray, 4x4 to 2x2, Brushed, SS304
Transition Cover Sloped to Flat Right Hand CleanTray, 4.00x4.00, Brushed, SS304

CTS44TCRSS

Transition Cover Sloped to Flat Right Hand CleanTray, 4.00x4.00, Brushed, SS304
Divider CleanTray 90-Degree Tee Top Cover, 4.00x4.00, Brushed, SS304

CT44DTFCSS

Divider CleanTray 90-Degree Tee Top Cover, 4.00x4.00, Brushed, SS304
Divider 45-Degree Elbow Top Cover CleanTray, 4.00x4.00, Brushed, SS304

CT44DEFC45SS

Divider 45-Degree Elbow Top Cover CleanTray, 4.00x4.00, Brushed, SS304
Closure Plate CleanTray Sloped Top Right, 4.00x4.00, Brushed, SS304

CTS44CPRSS

Closure Plate CleanTray Sloped Top Right, 4.00x4.00, Brushed, SS304

How to Install the CT46EIC45SS Controller

This guide provides step-by-step instructions for installing and configuring the CT46EIC45SS controller, ensuring proper wiring and setup for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the CT46EIC45SS controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the controller's power terminals. Ensure the connections are tight and insulated to prevent short circuits.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals of the controller. Ensure the voltage matches the specifications outlined in the user manual.

  4. Configure initial settings

    Power on the controller and access the configuration menu. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure in the user manual to ensure the controller operates accurately. Adjust settings as necessary based on the calibration results.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.