nVent CT22TOCSS - 90-Degree Tee CleanTray Outside Cover, 2.00x2.00, Brushed, SS304
nVent

CT22TOCSS

UPC: 783510157845


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent CleanTray CT22TOCSS is a 90-degree tee outside cover designed for the nVent CleanTray stainless steel cable management system. This component, with SKU CT22TOCSS, provides a clean and durable solution for routing cables where two 90-degree transitions are required. Constructed from SS304 stainless steel with a brushed finish, it ensures exceptional corrosion resistance and aesthetic appeal in washdown or harsh environments. This outside cover is engineered for compatibility with the CleanTray system, protecting rated cabling in critical applications such as food and beverage, pharmaceuticals, and chemical processing. The 2.00x2.00 inch (51x51 mm) size ensures seamless integration with corresponding CleanTray components, delivering a professional finish and system integrity. Key features include superior SS304 material for rust and chemical resistance, a smooth brushed surface ideal for frequent cleaning, and precise engineering for 90-degree transitions. The cover maintains system integrity by preventing cable damage at critical turns and contributes to a clean, professional appearance in visible installations.
  • Clean Tray 90-Degree Tees are used for right-angle installations where two 90-degree transitions are required
  • The Clean Tray stainless steel system is designed to protect rated cabling in applications that require frequent washdown
  • Designed for 90-degree tee transitions in cable management systems
  • Compatible with nVent CleanTray system components
  • Ideal for washdown environments in food, pharmaceutical, and chemical industries

Specifications

Application
Power Distribution; Corrosive Environments; Hygienic Environments
Color
Unpainted
Finish
Brushed #3
Height
2 IN
Height
51 mm
Material
Stainless Steel
Modification Services
Yes
Product Family
CleanTray
Thickness
18 ga
Thickness
1.27 mm
Type
Tee
Type
Industrial Lay-in Wireway
Weight
2.82 lb
Width
2 IN
Width
51 mm
Wireway
Clean Tray Stainless Steel Cable Tray
Package Dimensions (L x W x H)
14.25 IN x 8.25 IN x 2.5 IN
Package Dimensions (L x W x H)
36.195 cm x 20.955 cm x 6.35 cm
Package Weight (Imperial)
2.820 L
Package Weight (Metric)
1.279 kg
L-Bracket CleanTray, 2.00x2.00, Brushed, SS304

CT22LB

L-Bracket CleanTray, 2.00x2.00, Brushed, SS304
90-Degree Elbow CleanTray Top Cover Perforated, 2.00x2.00, Brushed, SS304

CT22PEFC90SS

90-Degree Elbow CleanTray Top Cover Perforated, 2.00x2.00, Brushed, SS304
45-Deg Elbow Top Cover CleanTray, 2.00x2.00, Brushed, SS304

CT22EFC45SS

45-Deg Elbow Top Cover CleanTray, 2.00x2.00, Brushed, SS304
45-Deg Elbow Perf Top Cover CleanTray, 2.00x2.00, Brushed, SS304

CT22PEFC45SS

45-Deg Elbow Perf Top Cover CleanTray, 2.00x2.00, Brushed, SS304
Straight Section Splice Perforated CleanTray, 2.00x2.00, Brushed, SS304

CT22PSPSS

Straight Section Splice Perforated CleanTray, 2.00x2.00, Brushed, SS304
Reducer CleanTray Sloped Left, 6x6 to 4x4, Brushed, SS304

CTS6644RLSS

Reducer CleanTray Sloped Left, 6x6 to 4x4, Brushed, SS304
Reducer CleanTray Sloped Left, 4x6 to 4x4, Brushed, SS304

CTS4644RLSS

Reducer CleanTray Sloped Left, 4x6 to 4x4, Brushed, SS304
Reducer CleanTray Sloped Right, 6x6 to 4x6, Brushed, SS304

CTS6646RRSS

Reducer CleanTray Sloped Right, 6x6 to 4x6, Brushed, SS304
Reducer CleanTray Sloped Left, 4x6 to 3x3, Brushed, SS304

CTS4633RLSS

Reducer CleanTray Sloped Left, 4x6 to 3x3, Brushed, SS304
45-Deg Elbow Perf Top Cover Slope Inward CleanTray, 3.00x3.00, Brushed, SS304

CTS33PEFC45SS

45-Deg Elbow Perf Top Cover Slope Inward CleanTray, 3.00x3.00, Brushed, SS304
90-Degree Elbow CleanTray Top Cover without Tabs, 3.00x3.00, Brushed, SS304

CT33EFCNT90SS

90-Degree Elbow CleanTray Top Cover without Tabs, 3.00x3.00, Brushed, SS304
90-Degree Elbow CleanTray Perforated without Tabs, 3.00x3.00, Brushed, SS304

CT33PEFCNT90SS

90-Degree Elbow CleanTray Perforated without Tabs, 3.00x3.00, Brushed, SS304

How to Install the CT46EIC45SS Controller

This guide provides step-by-step instructions for installing and configuring the CT46EIC45SS controller, ensuring proper wiring and setup for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the CT46EIC45SS controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the controller's power terminals. Ensure the connections are tight and insulated to prevent short circuits.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals of the controller. Ensure the voltage matches the specifications outlined in the user manual.

  4. Configure initial settings

    Power on the controller and access the configuration menu. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure in the user manual to ensure the controller operates accurately. Adjust settings as necessary based on the calibration results.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.