Contact for Pricing
Overview
- Solid bottom
- Corner-formed doors
- External-formed 90-degree body flange
- 20-degree sloped-top cover for 38.00-in. (965-mm) tall console or 30-degree top cover for 48.00-in. (1219-mm) console
- Quarter-turn stainless steel latches hold top cover securely closed
- Door props hold top cover open at 90-degrees
- Integral water-shedding trough
- Collar studs for optional back panel
- Optional side panels (mounted to collar studs) expand equipment mounting space
- Tool-to-open 3-point latch on front access door; door is removable and reversible; 170-degree full-access opening
Specifications
Application | Controls and Drives;Corrosive Environments |
Back Panel | CP2442 |
Back Panel Height x Width | 1021 x 564 mm |
Back Panel Height x Width | 40.20 x 22.20 in |
Color | Unpainted |
Conductive Panel | CP2442G |
Data Pocket | Large |
Depth | 13 IN |
Depth | 18 |
Depth | 457 |
Finish | Brushed #4 |
Height | 44 IN |
Height | 48 |
Height | 1,219 |
Material | Stainless Steel;Stainless Steel 304 |
Material | Stainless Steel 304 |
Modification Services | Yes |
NEMA Rating | 4X |
NEMA Rating | 4X Watertight, corrosion-resistant |
Product Family | Concept |
Protection Rating | NEMA Type 12 |
Size | 48.00x24.00x18.00 in |
Thickness | 1.98 mm |
Thickness | 14 ga |
Thickness | 51.40mm (2.024") |
Type | HMI Enclosure Systems |
Type Number | Type 3R |
Weight | 112 lb |
Width | 23 IN |
Width | 24 |
Width | 610 |
Package Dimensions (L x W x H) | 49.5 IN x 26.5 IN x 26 IN |
Package Dimensions (L x W x H) | 125.73 cm x 67.31 cm x 66.04 cm |
Package Weight (Imperial) | 112.000 L |
Package Weight (Metric) | 50.803 kg |
How to Install the CFC482423SS Controller
This guide provides step-by-step instructions for installing and configuring the CFC482423SS Controller, ensuring proper wiring and initial setup.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Wire connectors, Grounding wires
- Mount the controller
Secure the CFC482423SS Controller to the designated mounting surface using the provided mounting screws. Ensure that it is level and firmly attached.
- Connect the wiring
Use wire strippers to prepare the ends of the wires. Connect the power supply wires to the designated terminals on the controller, ensuring correct polarity. Use wire connectors to secure the connections.
- Ground the controller
Attach the grounding wire to the grounding terminal on the controller. Ensure that the other end of the grounding wire is securely connected to a suitable ground point to prevent electrical shock.
- Power on the controller
Before energizing the circuit, double-check all connections and clearances. Once verified, power on the controller and observe for any error indicators.
- Configure the controller settings
Access the controller's configuration interface. Set the desired parameters according to your application requirements. Save the settings before exiting the configuration mode.
- Calibrate the controller
Follow the calibration procedure outlined in the user manual. Use a multimeter to verify output signals and adjust settings as necessary to ensure accurate operation.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.