nVent AFM24248SS - PharmaPro Flush-mount Hinge Cover Type 4X, 24x24x8, Brushed, SS 304
nVent

AFM24248SS

UPC: 783510149055


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent PharmaPro Flush-mount Hinge Cover (SKU: AFM24248SS) is constructed from SS 304 stainless steel with a brushed finish, offering Type 4X protection for pharmaceutical and biotech enclosures. Its dimensions are 24x24x8 inches, designed for flush mounting on block or stud walls. This cover minimizes crevices, preventing contaminant accumulation and facilitating stringent hygiene protocols. It is engineered to complement nVent PharmaPro enclosures, ensuring a tight seal against the wall for a clean appearance and reduced microbial growth risk. The Type 4X rating signifies protection against hose-directed water and dust ingress, suitable for wet cleaning processes. The brushed stainless steel finish enhances corrosion resistance and meets industry standards for low surface roughness (RA value), aiding disinfection and regulatory compliance (FDA, GMP). Installation is designed for straightforward attachment using nVent's mounting hardware. This hinge cover supports operational efficiency and regulatory adherence in production suites, cleanrooms, and laboratory settings.
  • Specifically designed for pharmaceutical industry—flush mounting and flat surfaces eliminate areas where contaminants can accumulate
  • Low RA value of PharmaPro finish minimizes surface crevices, allowing for a thorough wipe-down
  • Enclosure does not protrude into the manufacturing area
  • Mounting system included
  • Enclosure body manufactured from 14 gauge Type 304 stainless steel
  • Mounting flange manufactured from 10 gauge Type 316L stainless steel
  • Screw cover and hinged door manufactured from 12 gauge Type 316L stainless steel
  • Seams continuously welded and ground smooth
  • Type 316L stainless steel lift-off hinges used with hinged door
  • Type 316L stainless steel slotted oval-head fasteners used with screw cover

Specifications

Application
Corrosive Environments; Controls and Drives; Hygienic Environments
Application
Controls and Drives;Corrosive Environments;Hygienic Environments
Body Thickness
16 ga
Body Thickness
1.98 mm
Body Thickness
14 ga
Color
Brushed
Color
Unpainted
Cutout Size
25.00 x 25.00 in
Cutout Size
18.69 x 7.19 in
Depth
8 mm
Depth
203 mm
Door Thickness
2.78 mm
Door Thickness
14 ga
Door Thickness
12 ga
Finish
15-20 RA
Height
610 mm
Height
24 in
Ip Rating
IP66/IP67
IP Rating
IP66
Ip Rating
Type 4X
Latch Quantity
7
Material
Stainless Steel 316L
Material
Stainless Steel 304
Material
Stainless Steel;Stainless Steel 316L
Modification Services
Yes
Mounting Cutout
635 x 635 mm
Mounting Cutout
25.00 x 25.00 in
Mounting Type
Flush-Mount
Mounting Type
Flush Mount
NEMA Rating
4X Watertight, corrosion-resistant
NEMA Rating
4X
Nema Rating
Type 4X
Panel
CP2424
Product Family
PharmaPro
Protection Rating
NEMA Type 12
Series
PharmaPro
Size
24X24X8
Size
24.00x24.00x8.00 in
Type
Hazardous Location Enclosures
Type
Stainless Steel Wall Mounted Industrial Enclosures
Type Number
Type 3R
Weight
62 lb
Width
610 mm
Width
24 IN
Package Dimensions (L x W x H)
33.75 IN x 33 IN x 10.25 IN
Package Dimensions (L x W x H)
85.725 cm x 83.82 cm x 26.035 cm
Package Weight (Imperial)
62.000 L
Package Weight (Metric)
28.123 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the AFM24248SS Controller

This guide provides step-by-step instructions for installing and configuring the AFM24248SS Controller, ensuring proper wiring and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the AFM24248SS controller to the designated mounting surface using the provided mounting screws. Ensure the controller is level and securely fastened.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Ensure that the connections are tight and insulated to prevent short circuits.

  3. Verify the connections

    Use a multimeter to check the voltage at the power terminals of the controller. Ensure that the voltage matches the specifications outlined in the documentation before proceeding.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters as per your application requirements. Save the settings once completed.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the documentation to ensure accurate readings and performance. Adjust settings as necessary based on the calibration results.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.