Contact for Pricing
Overview
- 14" x 12" x 8" internal dimensions for housing electrical components
- Type 4X rating for corrosion, moisture, and dust resistance
- Continuous hinge with quarter-turn latches for tool-free access
- Light gray fiberglass construction resists UV and chemical exposure
- Pre-drilled mounting holes for versatile installation orientations
- Molded-in-place threaded brass inserts and plated steel screws are provided for mounting optional panels and terminal block kits
- Removable hinged cover attached to body with Type 316 stainless steel hinge pin
- Screw-cover enclosures are secured with two captivated Type 316 stainless steel slotted cover screws
- Enclosures with quick-release latches have corrosion-resistant polyester latches located in corners that provide unobstructed access to enclosure
- Hinge pin and bail are corrosion-resistant Type 316 stainless steel
Specifications
Aluminum Panel | A14P12AL |
Application | Controls and Drives;Corrosive Environments |
Application | Corrosive Environments; Controls and Drives |
Color | Gray |
Color | Grey |
Color | Light Gray |
Color Code | RAL 7035 |
Cover Style | Solid |
Depth | 203 mm |
Depth | 8 mm |
Finish | Smooth Matte |
Height | 14 IN |
Height | 356 mm |
IP Rating | IP66 |
Latch Type | Quick Release |
Material | Fiberglass |
Modification Services | Yes |
Mounting | Wall Mounting Brackets Available |
Mounting | 14.94 x 10.00 in |
Nema Rating | Type 4X |
NEMA Rating | 4X Watertight, corrosion-resistant |
NEMA Rating | 4X |
Overall Dimensions | 114 x 88 mm |
Overall Dimensions | 14.55 x 12.55 in |
Panel Size | 324 x 276 mm |
Panel Size | 12.75 x 10.88 in |
Protection Rating | NEMA Type 12 |
Size | 14x12x8 |
Size | 14.00x12.00x8.00 in |
Steel Panel | A14P12 |
Thickness | 51.40mm (2.024") |
Thickness | 0.16 in |
Type | Solid Cover, Quick Release |
Type | Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures |
Type Number | Type 13 |
Weight | 9 lb |
Width | 12 IN |
Width | 305 mm |
Package Dimensions (L x W x H) | 16.5 IN x 14.7 IN x 10.9 IN |
Package Dimensions (L x W x H) | 41.91 cm x 37.338 cm x 27.686 cm |
Package Weight (Imperial) | 9.000 L |
Package Weight (Metric) | 4.082 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackHow to Install the A14128CHQRFG Controller
This guide provides step-by-step instructions for installing and configuring the A14128CHQRFG Controller, ensuring proper grounding and wiring.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the A14128CHQRFG controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.
- Ground the equipment
Connect a grounding wire to the grounding bushing inside the enclosure. Ensure that all metallic conduit hubs are properly grounded according to the National Electrical Code.
- Connect wiring
Use terminal connectors to connect the power and signal wires to the appropriate terminals on the controller. Verify all connections are secure and insulated.
- Power on the controller
Turn on the power supply to the controller and check for proper operation using a multimeter. Ensure that the voltage levels are within the specified range.
- Configure the controller
Access the controller's configuration interface and set the necessary parameters according to your application requirements.
- Calibrate the controller
Follow the calibration procedure outlined in the user manual to ensure accurate readings and performance.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.