nVent A14128CHQRFG - Continuous Hinge QR Cover Enclosure 4X, 14x12x8, Light Gray, Fiberglass
nVent

A14128CHQRFG

UPC: 783510298005


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A14128CHQRFG Continuous Hinge QR Cover Enclosure is a Type 4X fiberglass enclosure designed for harsh industrial environments. Measuring 14" x 12" x 8" internally, this light gray enclosure provides corrosion-resistant protection for sensitive electrical components, control panels, and instrumentation. Constructed from fiberglass, it resists moisture, chemicals, and UV exposure, making it ideal for chemical processing, water treatment, offshore oil and gas, and food and beverage facilities. The continuous hinge with quarter-turn (QR) latches enables tool-free access for quick maintenance, reducing downtime. The double-latching mechanism ensures a secure seal against dust, water, and unauthorized entry. Pre-drilled mounting holes and modular design support versatile installation orientations. Compatible with optional accessories like gland plates and ventilation grilles, this enclosure meets rigorous industry standards for durability and reliability in coastal, cleanroom, and remote telecom applications.
  • 14" x 12" x 8" internal dimensions for housing electrical components
  • Type 4X rating for corrosion, moisture, and dust resistance
  • Continuous hinge with quarter-turn latches for tool-free access
  • Light gray fiberglass construction resists UV and chemical exposure
  • Pre-drilled mounting holes for versatile installation orientations
  • Molded-in-place threaded brass inserts and plated steel screws are provided for mounting optional panels and terminal block kits
  • Removable hinged cover attached to body with Type 316 stainless steel hinge pin
  • Screw-cover enclosures are secured with two captivated Type 316 stainless steel slotted cover screws
  • Enclosures with quick-release latches have corrosion-resistant polyester latches located in corners that provide unobstructed access to enclosure
  • Hinge pin and bail are corrosion-resistant Type 316 stainless steel

Specifications

Aluminum Panel
A14P12AL
Application
Controls and Drives;Corrosive Environments
Application
Corrosive Environments; Controls and Drives
Color
Gray
Color
Grey
Color
Light Gray
Color Code
RAL 7035
Cover Style
Solid
Depth
203 mm
Depth
8 mm
Finish
Smooth Matte
Height
14 IN
Height
356 mm
IP Rating
IP66
Latch Type
Quick Release
Material
Fiberglass
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
14.94 x 10.00 in
Nema Rating
Type 4X
NEMA Rating
4X Watertight, corrosion-resistant
NEMA Rating
4X
Overall Dimensions
114 x 88 mm
Overall Dimensions
14.55 x 12.55 in
Panel Size
324 x 276 mm
Panel Size
12.75 x 10.88 in
Protection Rating
NEMA Type 12
Size
14x12x8
Size
14.00x12.00x8.00 in
Steel Panel
A14P12
Thickness
51.40mm (2.024")
Thickness
0.16 in
Type
Solid Cover, Quick Release
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Type Number
Type 13
Weight
9 lb
Width
12 IN
Width
305 mm
Package Dimensions (L x W x H)
16.5 IN x 14.7 IN x 10.9 IN
Package Dimensions (L x W x H)
41.91 cm x 37.338 cm x 27.686 cm
Package Weight (Imperial)
9.000 L
Package Weight (Metric)
4.082 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A14128CHQRFG Controller

This guide provides step-by-step instructions for installing and configuring the A14128CHQRFG Controller, ensuring proper grounding and wiring.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the A14128CHQRFG controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Ground the equipment

    Connect a grounding wire to the grounding bushing inside the enclosure. Ensure that all metallic conduit hubs are properly grounded according to the National Electrical Code.

  3. Connect wiring

    Use terminal connectors to connect the power and signal wires to the appropriate terminals on the controller. Verify all connections are secure and insulated.

  4. Power on the controller

    Turn on the power supply to the controller and check for proper operation using a multimeter. Ensure that the voltage levels are within the specified range.

  5. Configure the controller

    Access the controller's configuration interface and set the necessary parameters according to your application requirements.

  6. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate readings and performance.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.