SolaHD STF1000-48D - STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 100.0, Minimum Wire Size AWG 2, Fuse/Circuit Breaker Ampacity: Suggested 100A, Maximum 125A, Three Phase (480 V Delta)
SolaHD

STF1000-48D

UPC: 783472700301


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD STF1000-48D is a robust active tracking filter designed for three-phase 480V Delta industrial power systems. With a substantial 100A current rating and a minimum wire size requirement of AWG 2, this filter ensures reliable power conditioning for demanding applications. It is cULus Listed, UL1283, and CSA C22.2 No. 8 certified, meeting stringent safety and performance standards. The STF1000-48D features active tracking technology that continuously monitors voltage and current, automatically adjusting to maintain optimal performance and prevent overloads. This advanced functionality provides crucial isolation, significantly reduces harmonic distortion, and enhances overall system stability. Ideal for critical infrastructure such as data centers, manufacturing plants, and utility-grade installations, the STF1000-48D by SolaHD offers durable construction and advanced engineering to protect sensitive equipment. Its suggested fuse/circuit breaker ampacity is 100A, with a maximum capability of 125A, offering flexibility in system design. The STF series filters are engineered to deliver consistent, clean power, thereby extending equipment lifespan and minimizing costly downtime. Upgrade your industrial power quality with the SolaHD STF1000-48D for dependable operation and enhanced energy efficiency.
  • 100A Current Rating for high-capacity industrial loads
  • 480V Three-Phase Delta operation
  • cULus Listed, UL1283, and CSA C22.2 No. 8 Certified for safety compliance
  • Active Tracking Technology for real-time voltage and current adjustment
  • Minimum Wire Size AWG 2 for robust electrical connections

Specifications

Package Dimensions (L x W x H)
25 IN x 20.8 IN x 15 IN
Package Dimensions (L x W x H)
63.5 cm x 52.832 cm x 38.1 cm
Package Weight (Imperial)
62.400 L
Package Weight (Metric)
28.305 kg
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 15.0, Minimum Wire Size AWG 14, Fuse/Circuit Breaker Ampacity: Suggested 15A, Maximum 18.75A, Three Phase (480 V Delta)

STF0150-48D

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 15.0, Minimum Wire Size AWG 14, Fuse/Circuit Breaker Ampacity: Suggested 15A, Maximum 18.75A, Three Phase (480 V Delta)
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 200.0, Minimum Wire Size AWG 3/0, Fuse/Circuit Breaker Ampacity: Suggested 200A, Maximum 250A, Three Phase (480 V Delta)

STF2000-48D

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 200.0, Minimum Wire Size AWG 3/0, Fuse/Circuit Breaker Ampacity: Suggested 200A, Maximum 250A, Three Phase (480 V Delta)
Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 75kVA, Vac Input 480, Vac Output 480Y/277, 60 Hz

63TCC375

Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 75kVA, Vac Input 480, Vac Output 480Y/277, 60 Hz
Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 30kVA, Vac Input 480, Vac Output 208Y/120, 60 Hz

63TCA330

Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 30kVA, Vac Input 480, Vac Output 208Y/120, 60 Hz
Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 30kVA, Vac Input 480, Vac Output 480Y/277, 60 Hz

63TCC330

Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 30kVA, Vac Input 480, Vac Output 480Y/277, 60 Hz
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 50.0, Minimum Wire Size AWG 4, Fuse/Circuit Breaker Ampacity: Suggested 50A, Maximum 62.5A, Three Phase (480 V Delta)

STF0500-48D

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 50.0, Minimum Wire Size AWG 4, Fuse/Circuit Breaker Ampacity: Suggested 50A, Maximum 62.5A, Three Phase (480 V Delta)
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 30.0, Minimum Wire Size AWG 10, Fuse/Circuit Breaker Ampacity: Suggested 30A, Maximum 37.5A, Three Phase (480 V Delta)

STF0300-48D

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 30.0, Minimum Wire Size AWG 10, Fuse/Circuit Breaker Ampacity: Suggested 30A, Maximum 37.5A, Three Phase (480 V Delta)
Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 20kVA, Vac Input 600, Vac Output 208Y/120, 60 Hz

63TDA320

Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 20kVA, Vac Input 600, Vac Output 208Y/120, 60 Hz
Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 75kVA, Vac Input 600, Vac Output 208Y/120, 60 Hz

63TDA375

Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 75kVA, Vac Input 600, Vac Output 208Y/120, 60 Hz
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 200.0, Minimum Wire Size AWG 3/0, Fuse/Circuit Breaker Ampacity: Suggested 200A, Maximum 250A, Three Phase (277/480 V wye)

STF2000-27Y

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 200.0, Minimum Wire Size AWG 3/0, Fuse/Circuit Breaker Ampacity: Suggested 200A, Maximum 250A, Three Phase (277/480 V wye)
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 100.0, Minimum Wire Size AWG 2, Fuse/Circuit Breaker Ampacity: Suggested 100A, Maximum 125A, Three Phase (277/480 V wye)

STF1000-27Y

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 100.0, Minimum Wire Size AWG 2, Fuse/Circuit Breaker Ampacity: Suggested 100A, Maximum 125A, Three Phase (277/480 V wye)
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 15.0, Minimum Wire Size AWG 14, Fuse/Circuit Breaker Ampacity: Suggested 15A, Maximum 18.75A, Three Phase (277/480 V wye)

STF0150-27Y

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 15.0, Minimum Wire Size AWG 14, Fuse/Circuit Breaker Ampacity: Suggested 15A, Maximum 18.75A, Three Phase (277/480 V wye)

Frequently Asked Questions

What is the warranty period for SolaHD STF Series filters?

SolaHD STF Series filters come with a ten-year limited warranty.

What certifications do STF Series filters hold?

STF Series filters are UL 1283 Listed, CSA C22.2 No. 8 compliant, and RoHS Compliant.

What is the recommended wire size for the STF1000-48D?

The suggested minimum wire size for the STF1000-48D is 2 AWG.

What is the suggested fuse ampacity for the STF1000-48D?

The suggested fuse/circuit breaker ampacity for the STF1000-48D is 100A.

What are the dimensions of the STF1000-48D enclosure?

The case dimensions for the STF1000-48D are 20.00 in x 16.00 in x 10.00 in.

What is the weight of the STF1000-48D filter?

The STF1000-48D filter weighs 65.0 lbs (29.48 kg).

What type of enclosure does the STF1000-48D use?

The STF1000-48D, being a three-phase unit, is housed in a NEMA 12 enclosure.

What is the Mean Time Between Failure (MTBF) for STF filters?

The Mean Time Between Failure (MTBF) for STF filters is greater than 100,000 hours, according to Mil Std. 217F.

What is the line frequency for STF Series filters?

The line frequency for STF Series filters is 50/60 Hz.

What is the primary function of STF Series filters?

STF Series Active Tracking® Filters provide clean AC power by eliminating lower voltage noise and guarding against damaging lower energy transients.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.