Contact for Pricing
Overview
- 30 A current rating with 37.5 A maximum ampacity for flexible system integration
- UL1283 ULCO, cULus, and CSA C22.2 No. 8 certified for safety and compliance
- Active tracking technology monitors voltage and current for precise load balancing
- Minimum wire size AWG 10 with recommended 30 A fuse or circuit breaker
- Ideal for motor control centers, distribution panels, and high-power industrial applications
Specifications
Package Dimensions (L x W x H) | 25 IN x 20.9 IN x 14.6 IN |
Package Dimensions (L x W x H) | 63.5 cm x 53.086 cm x 37.084 cm |
Package Weight (Imperial) | 52.900 L |
Package Weight (Metric) | 23.995 kg |

STF0150-48D
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 15.0, Minimum Wire Size AWG 14, Fuse/Circuit Breaker Ampacity: Suggested 15A, Maximum 18.75A, Three Phase (480 V Delta)
STF2000-48D
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 200.0, Minimum Wire Size AWG 3/0, Fuse/Circuit Breaker Ampacity: Suggested 200A, Maximum 250A, Three Phase (480 V Delta)
63TCC375
Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 75kVA, Vac Input 480, Vac Output 480Y/277, 60 Hz
63TCA330
Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 30kVA, Vac Input 480, Vac Output 208Y/120, 60 Hz
63TCC330
Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 30kVA, Vac Input 480, Vac Output 480Y/277, 60 Hz
STF0500-48D
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 50.0, Minimum Wire Size AWG 4, Fuse/Circuit Breaker Ampacity: Suggested 50A, Maximum 62.5A, Three Phase (480 V Delta)
STF1000-48D
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 100.0, Minimum Wire Size AWG 2, Fuse/Circuit Breaker Ampacity: Suggested 100A, Maximum 125A, Three Phase (480 V Delta)
63TDA320
Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 20kVA, Vac Input 600, Vac Output 208Y/120, 60 Hz
63TDA375
Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 75kVA, Vac Input 600, Vac Output 208Y/120, 60 Hz
STF2000-27Y
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 200.0, Minimum Wire Size AWG 3/0, Fuse/Circuit Breaker Ampacity: Suggested 200A, Maximum 250A, Three Phase (277/480 V wye)
STF1000-27Y
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 100.0, Minimum Wire Size AWG 2, Fuse/Circuit Breaker Ampacity: Suggested 100A, Maximum 125A, Three Phase (277/480 V wye)
STF0150-27Y
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 15.0, Minimum Wire Size AWG 14, Fuse/Circuit Breaker Ampacity: Suggested 15A, Maximum 18.75A, Three Phase (277/480 V wye)Frequently Asked Questions
What is the SolaHD STF Series?
The SolaHD STF Series consists of Active Tracking® Filters designed to provide clean AC power by eliminating lower voltage, high-frequency noise. They guard against damaging lower energy transients.
What type of noise does the STF filter?
The STF Series eliminates low voltage/high frequency noise, attenuating it to a minimum of 40dB in the 50 KHz to 50 MHz frequency range.
What certifications does the STF Series have?
The STF Series is UL 1283 Listed, CSA C22.2 No. 8 compliant for Electromagnetic Interference Filters, and RoHS Compliant.
What is the operating temperature range?
The operating temperature range for the STF Series is from -40°C to +45°C. It derates linearly to 60% at +70°C.
What is the warranty for this product?
The SolaHD STF Series comes with a ten-year limited warranty.
What is the Mean Time Between Failure (MTBF)?
The Mean Time Between Failure (MTBF) for the STF Series is greater than 100,000 hours, as per Mil Std. 217F.
What is the input voltage for 480 Vac models?
For 480 Vac models, the input voltage range is 0-520 Vrms.
What is the nominal current for STF0300-48D?
The nominal current rating for the STF0300-48D model is 30.0 Amps.
What is the suggested minimum wire size for STF0300-48D?
The suggested minimum wire size for the STF0300-48D model is 10 AWG.
What fuse or circuit breaker ampacity is suggested for STF0300-48D?
For the STF0300-48D, a 30A fuse or circuit breaker ampacity is suggested, with a maximum of 37.5A.
Frequently Asked Questions about SolaHD
What certifications and standards do SolaHD products comply with?
SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.
What industries and applications are SolaHD products used for?
SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.
What technical support does SolaHD offer?
SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.
What are the main product lines offered by SolaHD?
SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.
What are the key features of SolaHD products?
SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.
What environmental ratings do SolaHD products have?
SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What accessories are available for SolaHD products?
SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.
How are SolaHD products typically installed?
SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.