The S4K2U96BATC Extended Battery Cabinet from SolaHD delivers a robust 12V, 9.0Ah power solution designed for demanding industrial applications. Built with two 6V cells connected in series, it provides a stable voltage output while maintaining a compact footprint. The cabinet features a durable, corrosion‑resistant housing that protects internal components from harsh environments, making it suitable for factory floors, data centers, and field installations. Integrated ventilation and temperature monitoring ensure optimal operating conditions, extending battery life and reliability. Easy installation is facilitated by standard mounting hardware and clear labeling, allowing rapid deployment and minimal downtime. Whether you need backup power for critical equipment, a temporary power source, or a permanent energy storage solution, the S4K2U96BATC offers consistent performance, high capacity, and the brand reliability associated with SolaHD. Its specifications—12V nominal voltage and 9.0Ah capacity—make it compatible with a wide range of industrial control systems and power management units. Choose the S4K2U96BATC for dependable, efficient, and scalable power storage that meets the rigorous demands of modern industrial operations.
  • 12V nominal voltage with 9.0Ah capacity
  • Two 6V cells configured in series for reliable power
  • Durable enclosure with corrosion-resistant housing
  • Integrated ventilation and temperature monitoring
  • Easy installation with standard mounting hardware

Specifications

Application
Industrial Automation Systems, Critical Microprocessors and PC Based Systems, Robotics and Process Control, Programmable Logic Controllers (PLC), Mission Critical and High Speed Networks
Back-Up Time
11/27
Battery Type
Valve-regulated, non-spillable, lead acid
Current Rating
9.0Ah
Environmental Conditions
0 to 95 non-condensing
Frequency Rating, Maximum
70 Hz
Frequency Rating, Minimum
40 Hz
Height
3.4 in
Height
86.36 mm
Length
19.7 in
Length
500.38 mm
Material
Corrosion-resistant housing
Mounting
Securing Flanges. Rack Mounting Hardware is available.
Mounting Type
Standard mounting hardware
Number of Receptacles
6
Receptacle
5-15R
Series
S4K2
Special Features
Hardwire capability for permanent installation, Small 2U height maximizes available space, Input and output noise suppression, Higher output power factor of 0.90, PWM inverter reduces output voltage distortion, Add on batteries for extended back-ups, Integral sealed non-spillable batteries, Hot swappable user replaceable battery, Automatic restart, Automatic and manual battery test, Rack-mount or stand-alone tower mounting
Standard
cULus Listed, UPS Equipment: S4K2U-C: UL 1778, CSA C22.2 No. 107.3, ISTA Procedure 1A
Type
S4K2U-C Industrial On-Line UPS
Voltage Rating
120 VAC
Voltage Rating
12V
Wattage
630 WAT
Width
16.9 in
Width
429.26 mm
Package Dimensions (L x W x H)
28 IN x 10.9 IN x 22.7 IN
Package Dimensions (L x W x H)
71.12 cm x 27.686 cm x 57.658 cm
Package Weight (Imperial)
96.050 L
Package Weight (Metric)
43.568 kg
Extended Battery Cabinet for S4K2U7000C, S4K2U1000C (-5), S4K2U1500C, S4K2U1500C (-5), Quantity x Volt x Rating: 2 x 4 x 12V x 9.0Ah

S4K2U48BATC

Extended Battery Cabinet for S4K2U7000C, S4K2U1000C (-5), S4K2U1500C, S4K2U1500C (-5), Quantity x Volt x Rating: 2 x 4 x 12V x 9.0Ah
Extended Battery Cabinet for S4K6U10KC, Quantity x Volt x Rating: 2 x 6 x 12 V x 8.5 Ah

S4K288BATC

Extended Battery Cabinet for S4K6U10KC, Quantity x Volt x Rating: 2 x 6 x 12 V x 8.5 Ah
Internal Battery for S4K6U10KC, Quantity x Volt x Rating: 2 x 6 x 12 V x 8.5 Ah

S4K288INTBATC

Internal Battery for S4K6U10KC, Quantity x Volt x Rating: 2 x 6 x 12 V x 8.5 Ah
Extended Battery Cabinet for S4K4U6000C, Quantity x Volt x Rating: 2 x 6 x 12V x 8.5Ah

S4K144BATC

Extended Battery Cabinet for S4K4U6000C, Quantity x Volt x Rating: 2 x 6 x 12V x 8.5Ah
240VA 10A B DIN DC UPSWOBAT

SDU1024B

240VA 10A B DIN DC UPSWOBAT
36 Volt Clamp for STC-642 Series data/signal protection devices

STC-642-036

36 Volt Clamp for STC-642 Series data/signal protection devices
SDU DC - B Series 24V DIN Rail/Panel mount battery module (cable included)

SDU24BATB

SDU DC - B Series 24V DIN Rail/Panel mount battery module (cable included)
SDU Series Battery, 24 Vdc, DIN Rail/Panel Mount Battery Module (Cable Included)

SDU24BAT

SDU Series Battery, 24 Vdc, DIN Rail/Panel Mount Battery Module (Cable Included)
SDU Series Battery, 24 Vdc, External Battery Module (Cable Included)

SDU24BATEM

SDU Series Battery, 24 Vdc, External Battery Module (Cable Included)
SDU DC - B Series DIN Rail DC UPS, 480 VA, 24 V/20 A. Battery module is required

SDU2024B

SDU DC - B Series DIN Rail DC UPS, 480 VA, 24 V/20 A. Battery module is required
SDU Series optional 6 Foot Battery Module cable to 24 V DC UPS

SDU24EXTBC6

SDU Series optional 6 Foot Battery Module cable to 24 V DC UPS
SDU Series optional interface kit to convert relay contacts signal to DB9 signals

SDU24DB9

SDU Series optional interface kit to convert relay contacts signal to DB9 signals

Frequently Asked Questions

Which UPS models are compatible with the S4K2U96BATC?

The S4K2U96BATC is compatible with S4K2U700C, S4K2U1000C (-5), S4K2U1500C, S4K2U2000C (-5), and S4K2U3000C (-5) UPS models.

What are the dimensions of the S4K2U96BATC battery cabinet?

The S4K2U96BATC unit dimensions are 23.70 in D x 16.90 in W x 3.40 in H.

What is the unit weight of the S4K2U96BATC?

The S4K2U96BATC unit weighs 93.5 lbs (42.40 kg).

What type of battery is used in the S4K2U96BATC?

The S4K2U96BATC uses valve-regulated, non-spillable, lead acid batteries.

What is the battery configuration for the S4K2U96BATC?

The S4K2U96BATC contains 2 sets of 6 x 12 V x 9.0 Ah batteries.

What are the compatible battery part numbers for S4K2U96BATC?

Compatible battery part numbers for S4K2U96BATC are Panasonic/UP-RW1245 and CSB/UPS12460F2.

What is the operating temperature range for the S4K2U96BATC?

The operating temperature range for the S4K2U96BATC is 0°C to +40°C.

What is the storage temperature range for the S4K2U96BATC?

The storage temperature range for the S4K2U96BATC is -15°C to +50°C. High ambient temperatures will reduce battery life.

What is the relative humidity requirement for S4K2U96BATC?

The relative humidity requirement for the S4K2U96BATC is 0% to 95%, non-condensing.

What is the maximum operating elevation for S4K2U96BATC?

The maximum operating elevation for the S4K2U96BATC is up to 10,000 ft. (3,000 m).

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.