SolaHD GLS354-C - Single Output Switcher, Output: 15 V (12-24 V) at (23.3 A), Input: 85 - 264, 120 300 Vdc, Frequency: 47 - 63 HZ
SolaHD

GLS354-C

UPC: 783472171125


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD GLS354-C single output switcher provides a stable 15V output adjustable within 12-24V, delivering up to 23.3A for high-power industrial applications. Its wide input range of 85-264V AC/DC and 120-300V DC ensures compatibility with global power systems and eliminates the need for additional power conditioning. Operating at 47-63Hz, the switcher maintains consistent performance across diverse industrial environments. The GLS354-C is designed for integration into manufacturing lines, automation equipment, and power distribution hubs where reliable voltage regulation is critical. Its compact form factor and robust construction meet stringent industrial standards, ensuring longevity and dependable operation. With a UNSPSC code of 39121004 and US origin, the GLS354-C is a cost-effective solution for simplifying power system design and reducing overall system complexity.
  • 15V output adjustable from 12-24V at 23.3A for high-power applications
  • Wide input range: 85-264V AC/DC and 120-300V DC for global compatibility
  • Operates at 47-63Hz for consistent performance across power systems
  • Compact design with robust construction for industrial environments
  • UNSPSC 39121004 compliant, US-manufactured for reliability

Specifications

Application
For use in industrial and medical applications requiring standard footprint size and very high reliability
Brand Name
SolaHD
Connection Type
Wide Input (85-264 Vac/Vdc)
Connection Type
Wide Input (85-264 Vac / 120-300 Vdc)
Connection Type
Wide input 85-264V AC/DC
Current Rating
23.3 A
Efficiency
75% Typical at full load
Frequency
47-63 Hz
Frequency Rating
47-63 HZ
Height
2 IN
Length
9 IN
Mounting Type
Compact Design
Series
GLS354
Series
GLS354-C
Series
GLS Series
Size
Compact
Special Features
Industry standard footprints, Universal input, Full power to 50 DEG C, High demonstrated MTBF, Automatic overvoltage protection, Overload protection, Built-in EMI Filtering, Derated operation to 70 DEG C, +/- 2%, regulation on main output, 250 VA and higher VA size enclosed.
Standard
Non-Medical: EN60950, UL UL60950 E132002, CSA 22.2-234 Level 3 LR53982C, CB Certificate and report; CE Mark (LVD), Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-17
Type
GL Series Single & Multi Output Switchers
Voltage Rating
15 V (12-24 V)
Voltage Rating
85-264 Vac/120-300 Vdc
Width
5 IN
Package Dimensions (L x W x H)
9.8 IN x 6 IN x 2.7 IN
Package Dimensions (L x W x H)
24.892 cm x 15.24 cm x 6.858 cm
Package Weight (Imperial)
3.800 L
Package Weight (Metric)
1.724 kg
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included

3085

Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
N3 SCREW COVER - 10X10X6 - GRA

C3SC10106GY

N3 SCREW COVER - 10X10X6 - GRA
ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module

ACS380-040S-07A2-4

ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
BK63H 1P B2A 10kA 120/240VAC UL1077

0626030563

BK63H 1P B2A 10kA 120/240VAC UL1077
MC-50a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC50A-30-11-K7-S-E)

1338006700

MC-50a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC50A-30-11-K7-S-E)
GMD-16M DC240V 3W 1b EXP (GMD16M-30-01-UD-3W-S-E)

1270040900

GMD-16M DC240V 3W 1b EXP (GMD16M-30-01-UD-3W-S-E)
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.

1SNK705010R0000

Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
Pushbuttons. 104P heavy duty Oiltight Pushbutton. Nameplate. XN1B PR.No. CR100699

CR104PXN1B

Pushbuttons. 104P heavy duty Oiltight Pushbutton. Nameplate. XN1B PR.No. CR100699
C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A

XT2NU3090BFF000XXX

C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.

NNC75X75WH2

The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.
DS9 RECEPTACLE POLY BLUE SIZE 5 IP 66/67/69 3P+G 150 A 480 VAC 60 Hz

3194213000K04

DS9 RECEPTACLE POLY BLUE SIZE 5 IP 66/67/69 3P+G 150 A 480 VAC 60 Hz
HPS Open Style Control Transformer, 150VA 240x480V-120x240V 50/60Hz

C2G0150MQMJ

HPS Open Style Control Transformer, 150VA 240x480V-120x240V 50/60Hz

Frequently Asked Questions

What is the input voltage range for GL250 models?

The GL250 models accept an input voltage range of 85-264 Vac or 120-300 Vdc.

What is the operating temperature range for GL series?

The operating temperature range is 0° to 50°C ambient, with derated operation possible up to 70°C.

What safety approvals does the GL series have?

The GL series has extensive safety approvals including UL 60950, CSA C22.2 No. 234-M90, IEC60950-1, EN60950, and CE Mark (LVD).

What is the warranty period for GL series products?

All GL series models come with a two-year limited warranty.

How are GL series power supplies protected from overvoltage?

GL series power supplies feature automatic overvoltage protection. For 5V outputs, protection is 5.7 to 6.7 Vdc, and for other outputs, it is 10% to 25% above nominal.

What is the typical efficiency of GL250 models?

The GL250 models typically have an efficiency of 75% at full load.

What is the hold-up time for GL250 models?

The hold-up time for GL250 models is 20 ms at full load with a 115 Vac nominal line input.

What are the grounding requirements for mounting GL series?

Mounting holes M1 and M2 should be grounded for EMI purposes, and mounting hole M1 serves as the safety ground connection.

What is the MTBF for GL series power supplies?

The demonstrated MTBF for GL series power supplies is greater than 550,000 hours at full load and 25°C ambient conditions.

What is the inrush current for GL250 models?

The inrush current for GL250 models is 20 A maximum at cold start at 25°C.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.