The SolaHD EDT651H40S Drive Isolation Transformer (SKU: EDT651H40S) provides essential power conditioning for industrial drive systems up to 30 horsepower. This 40 kVA transformer features a 460 V Delta primary winding and a 460Y/266 V secondary winding, operating at a standard 60 Hz frequency. Its design ensures robust electrical isolation, protecting sensitive motor drives and variable frequency drives (VFDs) from voltage spikes, transients, and electrical noise. This isolation is critical for extending equipment lifespan and minimizing downtime in demanding industrial environments. The EDT651H40S is cULus Listed (E7014), UL 506 Listed, CSA C22.2No.66 Certified, UL Listed (E25872), and UL 1561 Listed, meeting stringent safety and performance standards for reliable operation. Engineered for efficiency with low loss characteristics, it supports high current loads effectively. Its compact construction facilitates easy integration into motor control centers, automation systems, and power distribution panels. Ideal for applications requiring precise voltage regulation and enhanced power quality, the SolaHD EDT651H40S is a dependable choice for industrial automation, robotics, and heavy machinery control. Choose SolaHD for durable, compliant, and efficient power solutions.
  • 40 kVA rating for robust power delivery
  • 30 HP drive horsepower capability
  • 460 V Delta primary and 460Y/266 V secondary windings
  • 60 Hz operating frequency
  • cULus, UL, and CSA certifications for safety and reliability

Specifications

Application
Drive Isolation
Connection Type
Delta (Primary), 460Y/266 (Secondary)
Connection Type
Delta Primary / 460Y/266 Secondary
Current Rating
52.5 A
Current Rating
40 kVA
Frequency
60 Hz
KVA Rating
40 kVA
Mounting
Floor
Number Of Phases
3
Primary Voltage 1, Maximum
460D V
Primary Voltage 1, Minimum
460D V
Primary Voltage 2, Maximum
460D V
Primary Voltage 2, Minimum
460D V
Primary Voltage 3, Maximum
460D V
Primary Voltage 3, Minimum
460D V
Secondary Voltage 1, Maximum
460Y/266Y V
Secondary Voltage 1, Minimum
460Y/266Y V
Secondary Voltage 2, Maximum
460Y/266Y V
Secondary Voltage 2, Minimum
460Y/266Y V
Secondary Voltage 3, Maximum
460Y/266Y V
Secondary Voltage 3, Minimum
460Y/266Y V
Series
EDT651H
Special Features
Enhanced Enclosure Design
Temperature Rating, Maximum
302 F
Temperature Rating, Maximum
150 C
Temperature Rating, Minimum
302 F
Temperature Rating, Minimum
150 C
Type
SCR
Voltage Rating
460 V Delta Primary / 460Y/266 V Secondary
Voltage Rating
460 V
Voltage Rating
460 V (Primary) / 266 V (Secondary)
Voltage Rating
460 VAC
Package Dimensions (L x W x H)
32 IN x 31 IN x 35 IN
Package Dimensions (L x W x H)
81.28 cm x 78.74 cm x 88.9 cm
Package Weight (Imperial)
335.0000 L
Package Weight (Metric)
151.9560 kg
Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT631H75S

Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H34S

Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H14S

Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT651H27S

Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H27S

Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H51S

Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT651H51S

Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT631H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 75 kVA, Drive Horse Power 60, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT631H93S

Drive Isolation Transformer, 75 kVA, Drive Horse Power 60, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT651H14S

Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H20S

Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 575 Delta Primary, 230Y/133 Secondary, 60 HZ, cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT631H40S

Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 575 Delta Primary, 230Y/133 Secondary, 60 HZ, cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.