SolaHD EDT631H20S - Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
SolaHD

EDT631H20S

UPC: 783472023448


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD Drive Isolation Transformer, SKU EDT631H20S, provides robust electrical isolation for industrial motor drive applications. This transformer is rated at 20 kVA and is designed to handle a 15 HP drive power rating, making it suitable for demanding motor control systems. It features a 575 Delta primary winding and a 230Y/133V secondary winding, operating at a standard 60 Hz frequency. Engineered for reliability and safety, the EDT631H20S is cULus Listed (E7014), UL 506, CSA C22.2No.66, UL Listed (E25872), and UL1561 certified. These certifications ensure compliance with stringent industrial electrical standards. The drive isolation function protects sensitive motor drives from voltage spikes, harmonics, and electrical noise, thereby extending equipment lifespan and minimizing operational downtime. Its design emphasizes efficient magnetic performance with low core losses. The transformer's specifications include a 575 V Delta primary and a 230Y/133 V secondary output. This unit is ideal for applications such as CNC machines, conveyor belts, robotic drives, and other industrial automation equipment where clean and stable power is critical. The SolaHD EDT631H20S offers dependable isolation, high efficiency, and long service life, supporting manufacturers in maintaining productivity and adhering to safety standards.
  • 20 kVA power rating
  • 15 HP drive power rating
  • 575 Delta Primary, 230Y/133 Secondary
  • 60 Hz operating frequency
  • cULus, UL, and CSA Listed

Specifications

Application
Drive Isolation
Frequency
60 Hz
KVA Rating
20 kVA
Mounting
Floor
Number Of Phases
3
Primary Voltage 1, Maximum
575D V
Primary Voltage 1, Minimum
575D V
Primary Voltage 2, Maximum
575D V
Primary Voltage 2, Minimum
575D V
Primary Voltage 3, Maximum
575D V
Primary Voltage 3, Minimum
575D V
Secondary Voltage 1, Maximum
230Y/133 V
Secondary Voltage 1, Minimum
230Y/133 V
Secondary Voltage 2, Maximum
230Y/133 V
Secondary Voltage 2, Minimum
230Y/133 V
Secondary Voltage 3, Maximum
230Y/133 V
Secondary Voltage 3, Minimum
230Y/133 V
Special Features
Enhanced Enclosure Design
Temperature Rating, Maximum
302 F
Temperature Rating, Maximum
150 C
Temperature Rating, Minimum
302 F
Temperature Rating, Minimum
150 C
Type
SCR
Package Dimensions (L x W x H)
32 IN x 31 IN x 29 IN
Package Dimensions (L x W x H)
81.28 cm x 78.74 cm x 73.66 cm
Package Weight (Imperial)
220.0000 L
Package Weight (Metric)
99.7920 kg
Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H20S

Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 575 Delta Primary, 230Y/133 Secondary, 60 HZ, cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT631H40S

Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 575 Delta Primary, 230Y/133 Secondary, 60 HZ, cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H34S

Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT651H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H14S

Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT631H27S

Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT631H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT651H63S

Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT631H75S

Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H51S

Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 11 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H11S

Drive Isolation Transformer, 11 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H63S

Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.