SolaHD DT661H93S - Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
SolaHD

DT661H93S

UPC: 783472542802


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD DT661H93S Drive Isolation Transformer (SKU: DT661H93S) provides essential power conditioning for industrial motor drive systems. This transformer features a 93 kVA rating, efficiently converting 460 Delta primary voltage to a 230Y/133 secondary voltage at 60 Hz. Designed for drive isolation, it effectively reduces electrical noise and harmonics generated by variable frequency drives (VFDs) and other motor control equipment, thereby protecting sensitive downstream components and ensuring stable operation. Its construction adheres to stringent safety and performance standards, evidenced by its cULus Listing (E7014, UL 506, CSA C22.2 No.66) and UL Listing (E25872, UL1561). The DT661H93S is an ideal choice for applications requiring reliable voltage transformation and noise suppression in industrial automation, manufacturing lines, and heavy machinery. Its robust design ensures longevity and consistent performance in demanding operational environments, contributing to overall system reliability and reduced maintenance needs. This transformer is a cost-effective solution for enhancing the performance and lifespan of motor control circuits.
  • 93 kVA power rating for robust industrial applications
  • 460 Delta primary voltage, 230Y/133 secondary voltage
  • 60 Hz operating frequency
  • Drive isolation to reduce electrical noise and protect equipment
  • cULus and UL listed for safety and compliance

Specifications

Application
Drive Isolation
Frequency
60 Hz
KVA Rating
93 kVA
Mounting
Floor
Number Of Phases
3
Primary Voltage 1, Maximum
460D V
Primary Voltage 1, Minimum
460D V
Primary Voltage 2, Maximum
460D V
Primary Voltage 2, Minimum
460D V
Primary Voltage 3, Maximum
460D V
Primary Voltage 3, Minimum
460D V
Secondary Voltage 1, Maximum
230Y/133 V
Secondary Voltage 1, Minimum
230Y/133 V
Secondary Voltage 2, Maximum
230Y/133 V
Secondary Voltage 2, Minimum
230Y/133 V
Secondary Voltage 3, Maximum
230Y/133 V
Secondary Voltage 3, Minimum
230Y/133 V
Temperature Rating, Maximum
302 F
Temperature Rating, Maximum
150 C
Temperature Rating, Minimum
302 F
Temperature Rating, Minimum
150 C
Type
SCR
Drive Isolation Transformer, 75 kVA, Drive Horse Power 60, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT631H75S

Drive Isolation Transformer, 75 kVA, Drive Horse Power 60, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H14S

Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H27S

Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT651H51S

Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT631H20S

Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H34S

Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT631H75S

Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT661H20S

Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT651H11S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT631H51S

Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT651H34S

Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

Frequently Asked Questions

What is the primary application of these transformers?

SolaHD Drive Isolation Transformers are designed for SCR (Silicon Control Rectifier) variable speed motor drive applications. They magnetically isolate the incoming line from the motor drive.

What kVA range do these transformers cover?

These transformers are available from 7.5 kVA through 440 kVA, in 3 Phase, 60 Hz configurations.

Do these transformers offer voltage adjustment capabilities?

Yes, all units include taps for adjustments to the incoming source voltage. They also feature a full capacity secondary neutral as required by the National Electric Code.

What is the warranty period for SolaHD transformers?

SolaHD Drive Isolation Transformers come with a 10-year limited warranty.

What certifications do these transformers hold?

All models are UL Listed (E25872 UL 1561 or E77014 UL 5085) and RoHS Compliant. Some models are also cULus E77014 and CSA marked.

What are the dimensions of the 93 kVA transformer?

The 93 kVA transformer (EDT661H93S) has dimensions of 34.00 in height, 28.00 in width, and 26.00 in depth.

What is the approximate shipping weight of the 93 kVA model?

The approximate shipping weight for the 93 kVA model (EDT661H93S) is 637.0 lbs (289.00 kg).

What are the primary and secondary voltages for the DT661H93S?

For the DT661H93S (Group II), the primary voltage is 460 Delta and the secondary voltage is 230Y/133.

What are the available primary voltage tap settings?

For a 460 Delta primary, the available tap settings are 483V, 460V, and 437V. For a 575 Delta primary, settings are 604V, 575V, and 546V.

What is the purpose of a drive isolation transformer?

A drive isolation transformer magnetically isolates the incoming line from the motor drive and provides a voltage change to match the SCR Drive's required voltage.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.