Contact for Pricing
Overview
- 220 kVA rating for high‑horsepower drive support
- 460 V primary, 230 Y/133 V secondary for flexible integration
- UL/CSA listed (E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561) for safety compliance
- Delta primary and wye secondary configuration
- Compact design for space‑constrained installations
Specifications
Package Weight (Imperial) | 22.000 L |
Package Weight (Metric) | 9.979 kg |

DT631F7.5S
Drive Isolation Transformer, 7.5 kVA, Drive Horse Power 5, 575 Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
DT651H20S
Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
DT631H40S
Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 575 Delta Primary, 230Y/133 Secondary, 60 HZ, cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
DT651H34S
Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
DT651H440S
Drive Isolation Transformer, 440 kVA, Drive Horse Power 400, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
DT631H75S
Drive Isolation Transformer, 75 kVA, Drive Horse Power 60, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
DT631H440S
Drive Isolation Transformer, 440 kVA, Drive Horse Power 400, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
DT651H14S
Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
DT651H27S
Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
DT651H145S
Drive Isolation Transformer, 145 kVA, Drive Horse Power 125, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
DT651H330S
Drive Isolation Transformer, 330 kVA, Drive Horse Power 300, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
DT651H118S
Drive Isolation Transformer, 118 kVA, Drive Horse Power 100, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561Frequently Asked Questions
What is the purpose of SolaHD drive isolation transformers?
SolaHD drive isolation transformers magnetically isolate the incoming line from the motor drive for SCR variable speed motor drive applications. They also provide voltage change to match SCR Drive requirements.
What are the kVA and horsepower ratings for DT661H220S?
The DT661H220S transformer has a 220 kVA rating and supports a 200 horsepower drive.
What are the dimensions and weight of the DT661H220S?
The DT661H220S measures 46.00 in high, 36.00 in wide, and 24.00 in deep, with an approximate shipping weight of 1280.0 lbs.
What is the primary and secondary voltage for DT661H220S?
The DT661H220S has a 460 Delta Primary and a 230Y/133 Secondary voltage configuration.
What certifications do SolaHD drive isolation transformers hold?
These transformers are UL Listed under E77014 (UL 506, CSA C22.2 No. 66) and E25872 (UL 1561).
What weather shield is compatible with the DT661H220S?
The compatible weather shield for the DT661H220S is model WS-11. Weather shields come in a set of two and must be ordered separately.
What is the warranty period for these transformers?
SolaHD drive isolation transformers come with a 10-year limited warranty.
What are the primary applications for these transformers?
These transformers are specifically designed for SCR (Silicon Control Rectifier) variable speed motor drive applications.
What are the key features of SolaHD drive isolation transformers?
Key features include isolation to minimize load disturbances, voltage adjustment taps, full capacity secondary neutral, and shielding to attenuate line to ground noise. They also come with a 10-year limited warranty.
Is a weather shield required for NEMA 3R rating?
Yes, NEMA Type 3R enclosures are achieved when the transformer is used with an optional weather shield, which must be ordered separately.
Frequently Asked Questions about SolaHD
What certifications and standards do SolaHD products comply with?
SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.
What industries and applications are SolaHD products used for?
SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.
What technical support does SolaHD offer?
SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.
What are the main product lines offered by SolaHD?
SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.
What are the key features of SolaHD products?
SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.
What environmental ratings do SolaHD products have?
SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What accessories are available for SolaHD products?
SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.
How are SolaHD products typically installed?
SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.