SolaHD DT651H34S - Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
SolaHD

DT651H34S

UPC: 783472400614


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD DT651H34S is a high-performance Drive Isolation Transformer designed for demanding industrial applications. With a 34 kVA capacity and a 25 HP drive power rating, it provides robust power handling while maintaining precise isolation between primary and secondary circuits. The transformer operates at 460 V/60 Hz, featuring a 460 Delta primary and a 460Y/266 secondary winding configuration that ensures efficient voltage transformation and optimal load balance. Safety and reliability are paramount, as evidenced by its extensive certification suite: UL/CUL listed (E7014, UL506, CSA C22.2No.66, UL25872, UL1561). This certification guarantees compliance with stringent industrial standards, making the DT651H34S suitable for use in environments where safety and performance cannot be compromised. Its compact footprint and high isolation voltage make it ideal for integration into limited spaces, while its design facilitates easy installation and maintenance. Whether used in motor drives, power distribution, or process control systems, the SolaHD DT651H34S delivers dependable, efficient power isolation, helping to protect equipment and improve overall system reliability.
  • 34 kVA capacity with 25 HP drive power rating
  • 460 V/60 Hz frequency, 460 Delta primary, 460Y/266 secondary winding configuration
  • UL/CUL/CSA certified (E7014, UL506, CSA C22.2No.66, UL25872, UL1561) for safety compliance
  • Compact design with high isolation voltage, suitable for harsh industrial environments
  • Easy installation and maintenance, compatible with standard drive systems

Specifications

Application
Drive Isolation
Application
SCR Variable Speed Drives
Brand Name
SolaHD
Enclosure
Nema 3R with weather shield
Frequency
60 Hz
Frequency Rating
60 HZ
Height
23 IN
KVA Rating
34 kVA
Length
14 IN
Mounting
Floor
NEMA Frame Size
NEMA 3R
Number Of Phases
3
Primary Voltage
460 Delta
Primary Voltage 1, Maximum
460D V
Primary Voltage 1, Minimum
460D V
Primary Voltage 2, Maximum
460D V
Primary Voltage 2, Minimum
460D V
Primary Voltage 3, Maximum
460D V
Primary Voltage 3, Minimum
460D V
Secondary Voltage
230Y/133
Secondary Voltage 1, Maximum
460Y/266Y V
Secondary Voltage 1, Minimum
460Y/266Y V
Secondary Voltage 2, Maximum
460Y/266Y V
Secondary Voltage 2, Minimum
460Y/266Y V
Secondary Voltage 3, Maximum
460Y/266Y V
Secondary Voltage 3, Minimum
460Y/266Y V
Special Features
Isolation minimizes load disturbances caused by the SCR drive. Taps on all units for adjustments to incoming source voltage. Full capacity secondary neutral as required by the NEC.
Standard
cULus Listed: E77014, UL 506, CSA C22.2 No. 66, Listed E25872, UL 1561
Temperature Rating, Maximum
302 F
Temperature Rating, Maximum
150 C
Temperature Rating, Minimum
302 F
Temperature Rating, Minimum
150 C
Type
Drive Isolation Transformers: 7.5-440 kVA, Three Phase
Type
SCR
Voltage Rating
460 VAC
Width
18 IN
Package Dimensions (L x W x H)
16.5 IN x 23.5 IN x 34 IN
Package Dimensions (L x W x H)
41.91 cm x 59.69 cm x 86.36 cm
Package Weight (Imperial)
328.000 L
Package Weight (Metric)
148.781 kg
Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H14S

Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H20S

Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H20S

Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H14S

Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H51S

Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H40S

Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 75 kVA, Drive Horse Power 50, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H75S

Drive Isolation Transformer, 75 kVA, Drive Horse Power 50, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H40S

Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 75 kVA, Drive Horse Power 50, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H75S

Drive Isolation Transformer, 75 kVA, Drive Horse Power 50, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT651H27S

Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H27S

Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

Frequently Asked Questions

What is the kVA rating of the EDT651H34S transformer?

The EDT651H34S transformer has a 34 kVA rating.

What is the horsepower rating for the EDT651H34S?

The EDT651H34S transformer is rated for 25 horsepower drive applications.

What are the dimensions of the EDT651H34S transformer?

The dimensions are 28.00 in height, 23.00 in width, and 19 in depth.

What is the shipping weight of the EDT651H34S?

The approximate shipping weight of the EDT651H34S is 309.0 lbs (140.00 kg).

What is the primary voltage for the EDT651H34S transformer?

The EDT651H34S transformer uses a 460 Delta primary voltage.

What are the secondary voltage options for this transformer?

The secondary voltage options are 460Y/266 Volts.

What type of enclosure does the EDT651H34S use?

The EDT651H34S uses Enclosure Design Style 2, which is a ventilated enclosure.

What certifications do SolaHD Drive Isolation Transformers have?

All models are UL Listed (E25872 or E77014) and RoHS Compliant.

What is the warranty period for these SolaHD transformers?

SolaHD Drive Isolation Transformers come with a 10-year limited warranty.

What is the main application of these SolaHD transformers?

These transformers are specifically designed for SCR variable speed motor drive applications.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.