SolaHD DT651H220S - Drive Isolation Transformer, 220 kVA, Drive Horse Power 200, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
SolaHD

DT651H220S

UPC: 783472401567


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD DT651H220S Drive Isolation Transformer delivers 220 kVA of isolated power for 200 HP motor drive systems. This unit features a 460 Delta primary winding and a 460Y/266 Volt secondary configuration, operating at 60 Hz. Designed for VFD and sensitive motor control applications, it mitigates electrical noise and protects against voltage transients. The DT651H220S is cULus Listed (E7014, UL 506, CSA C22.2 No.66) and UL Listed (E25872, UL1561), ensuring compliance with North American safety standards. Its robust construction supports reliable performance in industrial environments, including factories and plants. The transformer’s secondary 460Y/266V output provides balanced three-phase power for variable frequency drives, reducing harmonic distortion and extending equipment lifespan. With a compact footprint and durable design, it is ideal for heavy-duty applications requiring clean, isolated power.
  • 220 kVA capacity for 200 HP drive systems
  • 460 Delta primary / 460Y/266V secondary configuration
  • 60 Hz operation with cULus and UL certifications
  • Mitigates electrical noise and voltage transients for VFDs
  • Robust construction for industrial environments

Specifications

Connection Type
Delta/Wye
Connection Type
Delta (Primary), 460Y/266 (Secondary)
Connection Type
460 Delta Primary, 460Y/266 Secondary
Connection Type
Delta (Primary), Y/266 (Secondary)
Connection Type
460 Delta Primary / 460Y/266 Secondary
Current Rating
220 kVA
Frequency
60 Hz
Series
DT651H
Series
DT651H220S
Size
220 kVA
Voltage Rating
460 V
Voltage Rating
460 VAC
Voltage Rating
460 VAC (Primary), 460Y/266 VAC (Secondary)
Package Dimensions (L x W x H)
9999 IN x 9999 IN x 9999 IN
Package Dimensions (L x W x H)
25397.46 cm x 25397.46 cm x 25397.46 cm
Package Weight (Imperial)
9999.000 L
Package Weight (Metric)
4535.546 kg
Drive Isolation Transformer, 275 kVA, Drive Horse Power 250, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H275S

Drive Isolation Transformer, 275 kVA, Drive Horse Power 250, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 175 kVA, Drive Horse Power 150, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT631H175S

Drive Isolation Transformer, 175 kVA, Drive Horse Power 150, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 118 kVA, Drive Horse Power 100, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H118S

Drive Isolation Transformer, 118 kVA, Drive Horse Power 100, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 440 kVA, Drive Horse Power 400, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H440S

Drive Isolation Transformer, 440 kVA, Drive Horse Power 400, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H34S

Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 145 kVA, Drive Horse Power 125, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H145S

Drive Isolation Transformer, 145 kVA, Drive Horse Power 125, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H14S

Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 145 kVA, Drive Horse Power 125, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H145S

Drive Isolation Transformer, 145 kVA, Drive Horse Power 125, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 275 kVA, Drive Horse Power 250, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H275S

Drive Isolation Transformer, 275 kVA, Drive Horse Power 250, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 330 kVA, Drive Horse Power 300, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H330S

Drive Isolation Transformer, 330 kVA, Drive Horse Power 300, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 175 kVA, Drive Horse Power 150, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H175S

Drive Isolation Transformer, 175 kVA, Drive Horse Power 150, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

Frequently Asked Questions

What is the kVA rating of the DT651H220S model?

The DT651H220S model has a kVA rating of 220 kVA.

What horsepower drive does the DT651H220S support?

The DT651H220S model supports a 200 horsepower drive.

What is the primary voltage for the DT651H220S model?

The DT651H220S model (Group I) has a 460 Delta Primary voltage.

What is the secondary voltage for the DT651H220S model?

The DT651H220S model (Group I) has a 460Y/266 Volt Secondary voltage.

What is the operating frequency of this transformer?

The transformer operates at 60 Hz.

What are the dimensions of the DT651H220S transformer?

The DT651H220S measures 46.00 in (height), 36.00 in (width), and 24.00 in (depth).

What is the approximate shipping weight of the DT651H220S?

The approximate shipping weight for the DT651H220S is 1280.0 lbs (581.00 kg).

What certifications does this transformer hold?

The transformer is UL Listed under E77014 (UL 506, CSA C22.2 No. 66) and E25872 (UL 1561).

What are the primary applications for this transformer?

SolaHD drive isolation transformers are designed for SCR (Silicon Control Rectifier) variable speed motor drive applications.

What type of enclosure does this transformer have?

The DT651H220S is a Style 1 Ventilated transformer. It can achieve NEMA Type 3R with an optional weather shield.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.