SolaHD DT651H145S - Drive Isolation Transformer, 145 kVA, Drive Horse Power 125, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
SolaHD

DT651H145S

UPC: 783472401468


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD DT651H145S Drive Isolation Transformer (SKU: DT651H145S) is engineered to provide reliable power isolation for industrial motor control applications. This transformer features a substantial 145 kVA rating, with a 460V Delta primary winding and a 460Y/266V secondary winding, offering versatile connectivity options. Designed with a Drive Horse Power rating of 125, it is specifically suited for isolating and protecting variable frequency drives (VFDs) and other motor control equipment from line noise and voltage fluctuations. Operating at a standard 60 Hz frequency, the DT651H145S ensures compatibility with most industrial power systems. Its construction adheres to stringent safety standards, evidenced by its cULus Listing (E7014), UL 506, CSA C22.2No.66, UL Listed E25872, and UL1561 certifications, providing assurance of safe and dependable operation in demanding industrial environments. The transformer's design prioritizes efficiency and durability, making it an essential component for enhancing power quality and extending the lifespan of connected motor loads.
  • 145 kVA power rating for robust industrial applications
  • 460V Delta primary and 460Y/266V secondary windings
  • 125 Drive Horse Power rating for motor control
  • 60 Hz operating frequency
  • cULus Listed (E7014), UL 506, CSA C22.2No.66, UL Listed E25872, UL1561 certified

Specifications

Application
SCR Variable Speed Drives
Brand Name
SolaHD
Connection Type
Delta/460Y/266
Enclosure
Nema 3R with weather shield
Frequency
60 Hz
Frequency Rating
60 HZ
Height
44 IN
KVA Rating
118
Length
21 IN
NEMA Frame Size
NEMA 3R
Number Of Phases
3
Primary Voltage
460 Delta
Primary Voltage 1, Maximum
460
Primary Voltage 1, Minimum
460
Primary Voltage 2, Maximum
460
Primary Voltage 2, Minimum
460
Primary Voltage 3, Maximum
460
Primary Voltage 3, Minimum
460
Secondary Voltage
460Y/266
Secondary Voltage 1, Maximum
460Y/266
Secondary Voltage 1, Minimum
460Y/266
Secondary Voltage 2, Maximum
460Y/266
Secondary Voltage 2, Minimum
460Y/266
Secondary Voltage 3, Maximum
460Y/266
Secondary Voltage 3, Minimum
460Y/266
Series
DT651H
Special Features
Isolation minimizes load disturbances caused by the SCR drive. Taps on all units for adjustments to incoming source voltage. Full capacity secondary neutral as required by the NEC.
Standard
cULus Listed: E77014, UL 506, CSA C22.2 No. 66, Listed E25872, UL 1561
Type
Drive Isolation Transformers: 7.5-440 kVA, Three Phase
Voltage Rating
460 V
Width
33 IN
Package Dimensions (L x W x H)
40 IN x 40 IN x 49 IN
Package Dimensions (L x W x H)
101.6 cm x 101.6 cm x 124.46 cm
Package Weight (Imperial)
892.000 L
Package Weight (Metric)
404.611 kg
Drive Isolation Transformer, 118 kVA, Drive Horse Power 100, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H118S

Drive Isolation Transformer, 118 kVA, Drive Horse Power 100, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 75 kVA, Drive Horse Power 50, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H75S

Drive Isolation Transformer, 75 kVA, Drive Horse Power 50, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H34S

Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H14S

Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H20S

Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 7.5 kVA, Drive Horse Power 5, 460 Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651F7.5S

Drive Isolation Transformer, 7.5 kVA, Drive Horse Power 5, 460 Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H40S

Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H51S

Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H40S

Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 75 kVA, Drive Horse Power 50, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H75S

Drive Isolation Transformer, 75 kVA, Drive Horse Power 50, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H20S

Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

Frequently Asked Questions

What are the kVA and horsepower ratings for DT651H145S?

The DT651H145S transformer has a 145 kVA rating and is suitable for 125 drive horsepower applications.

What are the primary and secondary voltages for DT651H145S?

The DT651H145S has a 460 Delta primary and a 460Y/266 Volt secondary.

What is the warranty period for SolaHD drive isolation transformers?

SolaHD drive isolation transformers come with a 10-year limited warranty.

What NEMA enclosure rating does this transformer have?

The transformer has a UL Listed/NEMA Type 3R enclosure when used with an optional weather shield.

Is a weather shield required for NEMA 3R rating?

Yes, an optional weather shield (WS-10 for DT651H145S) is required for NEMA Type 3R enclosure rating. Weather shields are ordered separately.

What are the dimensions and shipping weight of the DT651H145S?

The DT651H145S measures 44.00 in high, 33.00 in wide, and 21.00 in deep, with an approximate ship weight of 920.0 lbs.

What certifications do SolaHD drive isolation transformers hold?

These transformers are UL Listed to UL 506 and UL 1561, and CSA Listed to C22.2 No. 66.

What is the design style of the DT651H145S transformer?

The DT651H145S transformer is of Design Style 1, which is a Ventilated type.

What primary voltage taps are available for the 460 Delta primary?

For a 460 Delta primary, taps are available for 483V, 460V, and 437V.

What are the main applications for this drive isolation transformer?

SolaHD drive isolation transformers are specifically designed for SCR variable speed motor drive applications.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.