The SolaHD DT651H118S Drive Isolation Transformer, SKU DT651H118S, is a robust 118 kVA unit designed for critical industrial drive applications. It features a 460 Delta primary winding and a 460Y/266 secondary winding, operating at a standard 60 Hz frequency. This transformer is engineered to provide essential power isolation, protecting motor drives from voltage spikes, harmonics, and electrical noise, thereby extending equipment lifespan and enhancing overall system reliability. Its construction meets stringent safety and performance standards, evidenced by its cULus Listing (E7014), UL 506, CSA C22.2No.66, UL Listed E25872, and UL1561 certifications. The DT651H118S is ideal for use in manufacturing plants, process control systems, and any industrial setting requiring dependable isolation for drive power. It supports 100 HP drive applications, ensuring optimal performance and compatibility with a wide range of motor configurations. The transformer's efficient design contributes to reduced energy loss and operational costs. Its compact footprint and high-efficiency core minimize space requirements while maximizing output. The SolaHD DT651H118S combines efficiency, durability, and compliance, making it a dependable choice for modern industrial power systems that demand reliable isolation and protection for sensitive drive components. This unit is manufactured in the US.
  • 118 kVA capacity for heavy-duty industrial drives
  • 460 Delta primary and 460Y/266 secondary windings
  • 60 Hz operating frequency
  • cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
  • Protects drives from voltage spikes, harmonics, and electrical noise

Specifications

Application
For SCR (Silicon Control Rectifier) variable speed motor drive applications
Brand Name
SolaHD
Current Rating
118 kVA
Enclosure
Nema 3R with weather shield
Frequency
60 Hz
Frequency Rating
60 HZ
Height
34 IN
KVA Rating
93
Length
22 IN
NEMA Frame Size
NEMA 3R
Number Of Phases
3
Primary Voltage
460 Delta V
Primary Voltage 1, Maximum
460 V
Primary Voltage 1, Minimum
460 V
Primary Voltage 2, Maximum
460 V
Primary Voltage 2, Minimum
460 V
Primary Voltage 3, Maximum
460 V
Primary Voltage 3, Minimum
460 V
Secondary Voltage
460 Y/260 Secondary V
Secondary Voltage 1, Maximum
460 Y/260 Secondary V
Secondary Voltage 1, Minimum
460 Y/260 Secondary V
Secondary Voltage 2, Maximum
460 Y/260 Secondary V
Secondary Voltage 2, Minimum
460 Y/260 Secondary V
Secondary Voltage 3, Maximum
460 Y/260 Secondary V
Secondary Voltage 3, Minimum
460 Y/260 Secondary V
Series
DT651H118S
Special Features
10 Year Warranty, Shielding attenuates line to ground noise, Taps on all units for adjustment to incoming source voltage, Full capacity secondary neutral as required by NEC, NEAM 3R with optional Weather Shield
Standard
cULus: Listed: E77014, UL 506, CSA C22.2 No. 66, UL Listed: E25872, UL 1561
Type
Drive Isolation Transformer
Voltage Rating
460 Delta (Primary), 460Y/266 VAC (Secondary)
Width
28 IN
Package Dimensions (L x W x H)
40 IN x 40 IN x 51 IN
Package Dimensions (L x W x H)
101.6 cm x 101.6 cm x 129.54 cm
Package Weight (Imperial)
819.000 L
Package Weight (Metric)
371.498 kg
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 145 kVA, Drive Horse Power 125, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H145S

Drive Isolation Transformer, 145 kVA, Drive Horse Power 125, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 75 kVA, Drive Horse Power 50, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H75S

Drive Isolation Transformer, 75 kVA, Drive Horse Power 50, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H40S

Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H51S

Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H40S

Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 75 kVA, Drive Horse Power 50, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H75S

Drive Isolation Transformer, 75 kVA, Drive Horse Power 50, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H34S

Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H14S

Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H20S

Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 7.5 kVA, Drive Horse Power 5, 460 Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651F7.5S

Drive Isolation Transformer, 7.5 kVA, Drive Horse Power 5, 460 Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H20S

Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

Frequently Asked Questions

What is the kVA rating of the DT651H118S transformer?

The DT651H118S transformer has a kVA rating of 118 kVA.

What is the primary voltage for the DT651H118S?

The DT651H118S transformer has a 460 Delta Primary voltage.

What is the secondary voltage for the DT651H118S?

The DT651H118S transformer provides a 460Y/266 secondary voltage.

What are the dimensions of the DT651H118S transformer?

The DT651H118S measures 44.00 in height, 33.00 in width, and 21.00 in depth.

What is the shipping weight of the DT651H118S?

The approximate shipping weight for the DT651H118S transformer is 910.0 lbs (413.00 kg).

What is the design style of the DT651H118S transformer?

The DT651H118S transformer is of Design Style 1, which is a Ventilated design.

What is the frequency rating of the DT651H118S?

The DT651H118S transformer operates at 60 Hz.

What is the horsepower rating for the DT651H118S?

The DT651H118S transformer is rated for 100 Drive Horse Power.

What type of applications is this transformer designed for?

This transformer is specifically designed for SCR (Silicon Control Rectifier) variable speed motor drive applications.

Does the DT651H118S require a weather shield for NEMA 3R rating?

Yes, the DT651H118S requires the optional WS-10 weather shield to achieve a NEMA Type 3R enclosure rating. Weather shields must be ordered separately.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.