SolaHD DT631H63S - Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
SolaHD

DT631H63S

UPC: 783472401017


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD DT631H63S Drive Isolation Transformer (SKU: DT631H63S) is engineered for robust and reliable power isolation in industrial drive systems. This 63 kVA transformer features a 575 Delta primary winding and a 230Y/133 V secondary output, operating at a standard 60 Hz frequency. It is designed to support high-power applications while maintaining strict voltage regulation, crucial for sensitive motor control and automation equipment. The DT631H63S is built to meet stringent safety and performance standards, holding cULus Listing E7014, UL 506, CSA C22.2 No.66, UL Listed E25872, and UL 1561 certifications. These certifications ensure compliance with international electrical codes and provide confidence in its safety and reliability for demanding industrial environments. The transformer's design emphasizes efficient energy transfer and reduced core losses, making it an ideal choice for heavy-load drive applications. SolaHD's proven engineering expertise guarantees a long service life and low maintenance requirements. It is particularly well-suited for isolating motor drives, protecting sensitive electronic components from voltage spikes and electrical noise, and meeting regulatory requirements for power quality. Whether you are implementing CNC machines, industrial pumps, or automated assembly lines, the DT631H63S delivers the performance and safety expected from a premium industrial transformer. Its robust construction ensures durability even in harsh operating conditions, and the winding insulation is rated for high temperatures, contributing to its extended service life. Installation is straightforward, with clear labeling and pre-wired leads simplifying integration into existing systems. By isolating the motor drive from the main power source, the DT631H63S effectively reduces electromagnetic interference, enhancing overall system reliability and protecting valuable equipment.
  • 63 kVA power rating for substantial industrial loads
  • 575 Delta primary and 230Y/133 V secondary voltage configuration
  • 60 Hz operating frequency for standard industrial power systems
  • UL/CSA certified (E7014, UL 506, CSA C22.2No.66, UL E25872, UL1561) for safety and compliance
  • Designed for drive isolation, protecting sensitive equipment and reducing noise

Specifications

Application
Drive Isolation
Frequency
60 Hz
KVA Rating
63 kVA
Mounting
Floor
Number Of Phases
3
Primary Voltage 1, Maximum
575D V
Primary Voltage 1, Minimum
575D V
Primary Voltage 2, Maximum
575D V
Primary Voltage 2, Minimum
575D V
Primary Voltage 3, Maximum
575D V
Primary Voltage 3, Minimum
575D V
Secondary Voltage 1, Maximum
230Y/133 V
Secondary Voltage 1, Minimum
230Y/133 V
Secondary Voltage 2, Maximum
230Y/133 V
Secondary Voltage 2, Minimum
230Y/133 V
Secondary Voltage 3, Maximum
230Y/133 V
Secondary Voltage 3, Minimum
230Y/133 V
Temperature Rating, Maximum
302 F
Temperature Rating, Maximum
150 C
Temperature Rating, Minimum
302 F
Temperature Rating, Minimum
150 C
Type
SCR
Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H20S

Drive Isolation Transformer, 20 kVA, Drive Horse Power 15, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 575 Delta Primary, 230Y/133 Secondary, 60 HZ, cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT631H40S

Drive Isolation Transformer, 40 kVA, Drive Horse Power 30, 575 Delta Primary, 230Y/133 Secondary, 60 HZ, cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H34S

Drive Isolation Transformer, 34 kVA, Drive Horse Power 25, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT651H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT651H63S

Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT631H75S

Drive Isolation Transformer, 63 kVA, Drive Horse Power 50, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT661H14S

Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT631H27S

Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT631H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

EDT651H27S

Drive Isolation Transformer, 27 kVA, Drive Horse Power 20, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT631H14S

Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 575 Delta Primary, 230Y/133 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H51S

Drive Isolation Transformer, 51 kVA, Drive Horse Power 40, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

Frequently Asked Questions

What is the primary application of this transformer?

This transformer is specifically designed for SCR (Silicon Control Rectifier) variable speed motor drive applications, providing magnetic isolation and voltage matching.

What is the kVA rating for the DT631H63S model?

The DT631H63S model has a kVA rating of 63 kVA.

What horsepower drive does the DT631H63S support?

The DT631H63S model supports a 50 horsepower drive.

What is the primary voltage for the DT631H63S?

The DT631H63S model uses a 575 Delta Primary voltage.

What is the secondary voltage for the DT631H63S?

The DT631H63S model provides a 230Y/133 Volt Secondary voltage.

What is the warranty period for this product?

The product comes with a 10-year limited warranty.

What certifications does this transformer have?

All models are UL Listed (E25872 or E77014) and RoHS Compliant. Units are also CSA marked.

What are the dimensions of the DT631H63S model?

The DT631H63S measures 34.00 in height, 28.00 in width, and 26 in depth.

What is the approximate shipping weight of the DT631H63S?

The approximate shipping weight for the DT631H63S model is 479.0 lbs (217.00 kg).

What type of enclosure does this transformer use?

The transformer uses a ventilated enclosure, Design Style 2, and can achieve NEMA Type 3R with an optional weather shield.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.