Contact for Pricing
Overview
- OM5 multimode fiber for enhanced wavelength support (850nm-950nm)
- Low Smoke Zero Halogen (LSZH) jacket for plenum space safety compliance
- PanMPO Female-to-Female connectors with HD Flex Transition for high-density
- Method A polarity for duplex applications
- 83-meter length with integrated pulling eye for simplified installation
Specifications
Application | Data centers requiring quick infrastructure deployment with extended reach. Small diameter trunk cable assemblies use 30 to 40% less space which is ideal for high density cable applications. |
Color | Lime Green |
Environmental Conditions | Indoor |
Standard | Meets or exceeds ISO/IEC 11801, TIA/EIA-568-C.3, TIA-604-5 (FOCIS-5), TIA/EIA-568-C.1, RoHS compliant,TIA-492-AAAD, IED 60793-2-10 type A1a.3 |
Type | Trunk Cable Assembly |
Package Dimensions (L x W x H) | 21.4 IN x 21.4 IN x 6.7 IN |
Package Weight (Imperial) | 11.21 lbs |

ICD44T1NTL2M
The IndustrialNet M12 D-Code Category 5e Overmolded Cordset is female bulkhead to RJ45 preterminated with straight connectors. It is constructed of stranded, twisted pair cable for STP installations. The cordset is 600 V rated. The TPU jacket makes it suitable for high-flex applications for increased reliability. The cordset is 5 meters and teal.
ICD14T1NTL1M
The IndustrialNet M12 D-Code Category 5e Overmolded Cordset is male to RJ45 preterminated with straight connectors. It is constructed of stranded, twisted pair cable for STP installations. The cordset is 600 V rated. The TPU jacket makes it suitable for high-flex applications for increased reliability. The cordset is 1 meter and teal.
FWTRP7N7NKNF031
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 31 Feet
FWUYL7575LNM036
OM5, 24 Fiber Trunk, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, HD Flex Transition, Method B, Ultra Insertion Loss - 36 Meters
ICD14T1NTL5M
The IndustrialNet M12 D-Code Category 5e Overmolded Cordset is male to RJ45 preterminated with straight connectors. It is constructed of stranded, twisted pair cable for STP installations. The cordset is 600 V rated. The TPU jacket makes it suitable for high-flex applications for increased reliability. The cordset is 5 meters and teal.
ICD35T1NTL2M
The IndustrialNet M12 D-Code Category 5e Overmolded Cordset is male to female preterminated with angled connectors. It is constructed of stranded, twisted pair cable for STP installations. The cordset is 600 V rated. The TPU jacket makes it suitable for high-flex applications for increased reliability. The cordset is 2 meters and teal.
FWTRP7N7NKNF036
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 36 Feet
FWTRP7N7NLNF049
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 49 Feet
FWUYL7575LNM020
OM5, 24 Fiber Trunk, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, HD Flex Transition, Method B, Ultra Insertion Loss - 20 MetersFrequently Asked Questions
What are the main applications for these trunk cables?
QuickNet™ OM4 and OM5 Signature Core™ Trunk Cable Assemblies are designed for rapid deployment of high-density permanent links in data center applications. They are ideal for main, horizontal, and zone distribution areas.
What is the breakout length for these cables?
The breakout length for these trunk cable assemblies is 1 meter.
Are these cables RoHS compliant?
Yes, the QuickNet™ OM4 and OM5 Signature Core™ Trunk Cable Assemblies are RoHS compliant.
What are the standard lengths for OM5 trunk cables?
Standard lengths for OM5 Signature Core™ trunk cables range from 15 to 300 feet in 5-foot increments and 5 to 100 meters in 1-meter increments.
What are the standard lengths for OM4 trunk cables?
Standard lengths for OM4 Signature Core™ trunk cables range from 10 to 100 feet in 1-foot increments and 10 to 50 meters in 1-meter increments.
How many mating cycles can the connectors withstand?
The connectors on these trunk cable assemblies have a durability of 500 mating cycles.
What is the minimum bend radius for the cable?
The minimum bend radius is 20 times the cable outside diameter (OD) under load and 10 times the cable OD statically.
What is the maximum connector insertion loss?
The maximum connector insertion loss for these trunk cable assemblies is 0.25dB.
What is the operating temperature range for the cables?
The operating temperature range for these trunk cable assemblies is -20°C to 70°C (-4°F to 158°F).
What are the jacket rating options for the cables?
The cable jacket ratings available are Optical Fiber Non-conductive Plenum (OFNP) and Low Smoke Zero Halogen (LSZH).
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.