This Panduit OM5 12 Fiber Interconnect cable (SKU: FWTRP7N7NLNF034) is designed for high-density data center and enterprise network applications requiring superior performance and reliability. Featuring PanMPO female connectors on both ends, this cable utilizes Method B polarity, ensuring correct signal transmission in duplex applications. The OM5 multimode fiber supports a wide range of wavelengths, including the 850nm to 953nm range, enabling higher bandwidth and increased data rates for modern applications like 40GbE and 100GbE. Constructed with a plenum-rated jacket, this cable is suitable for use in air-handling spaces, meeting stringent safety requirements. The Ultra Insertion Loss specification indicates minimal signal degradation over the 34-foot length, crucial for maintaining signal integrity in demanding network environments. Manufactured in the US, this Panduit interconnect cable offers a dependable solution for your structured cabling needs, ensuring efficient data flow and future-proofing your infrastructure. The 12-fiber configuration provides ample capacity for parallel optics and other high-density interconnectivity requirements.
  • OM5 Multimode Fiber for enhanced bandwidth
  • 12 Fiber configuration for high-density applications
  • Plenum-rated jacket for safe installation in air-handling spaces
  • PanMPO Female to PanMPO Female connectors
  • Method B polarity for duplex applications

Specifications

Application
Data centers requiring quick infrastructure deployment with extended reach that want to maintain bandwidth throughout the infrastructure.
Color
Lime Green
Connection Type
PanMPO Female to PanMPO Female
Environmental Conditions
Indoor
Series
OM5
Size
34 Feet
Standard
Meets or exceeds ISO/IEC 11801, TIA/EIA-568-C.3, TIA-604-5 (FOCIS-5), TIA/EIA-568-C.1, RoHS compliant for OM4 ANSI/TIA-492AAAE, IEC 60793-2-10 Ed 6, TIA 568.3-D, ISO 11801 Ed 3, RoHS compliant for OM5
Type
Interconnect Cable Assembly
Package Dimensions (L x W x H)
14 IN x 17 IN x 1.5 IN
Package Weight (Imperial)
0.37 lbs
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 31 Feet

FWTRP7N7NKNF031

OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 31 Feet
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 36 Feet

FWTRP7N7NKNF036

OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 36 Feet
OM5, 12 Fiber Interconnect, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 11 Meters

FWTRL7N7NLNM011

OM5, 12 Fiber Interconnect, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 11 Meters
OM5, 24 Fiber Trunk, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, HD Flex Transition, Method B, Ultra Insertion Loss, with Pulling Eye on one end - 10 Meters

FWUYL7575LAM010

OM5, 24 Fiber Trunk, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, HD Flex Transition, Method B, Ultra Insertion Loss, with Pulling Eye on one end - 10 Meters
OM5, 12 Fiber Trunk, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, HD Flex Transition, Method A, Ultra Insertion Loss, with Pulling Eye on one end - 90 Meters

FWTYL7575KAM090

OM5, 12 Fiber Trunk, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, HD Flex Transition, Method A, Ultra Insertion Loss, with Pulling Eye on one end - 90 Meters
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 14 Feet

FWTRP7N7NKNF014

OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 14 Feet
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 55 Feet

FWTRP7N7NLNF055

OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 55 Feet
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 82 Feet

FWTRP7N7NLNF082

OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 82 Feet
OM5, 12 Fiber Interconnect, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 24 Meters

FWTRL7N7NLNM024

OM5, 12 Fiber Interconnect, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 24 Meters
OM5, 24 Fiber Trunk, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, HD Flex Transition, Method A, Ultra Insertion Loss, with Pulling Eye on one end - 10 Meters

FWUYL7575KAM010

OM5, 24 Fiber Trunk, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, HD Flex Transition, Method A, Ultra Insertion Loss, with Pulling Eye on one end - 10 Meters
OM5, 24 Fiber Trunk, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, HD Flex Transition, Method B, Ultra Insertion Loss - 25 Meters

FWUYL7575LNM025

OM5, 24 Fiber Trunk, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, HD Flex Transition, Method B, Ultra Insertion Loss - 25 Meters
OM5, 24 Fiber Trunk, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, HD Flex Transition, Method B, Ultra Insertion Loss, with Pulling Eye on one end - 53 Meters

FWUYL7575LAM053

OM5, 24 Fiber Trunk, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, HD Flex Transition, Method B, Ultra Insertion Loss, with Pulling Eye on one end - 53 Meters

Frequently Asked Questions

What fiber types do these patch cords support?

These patch cords support OM4 Signature Core™ and OM5 Signature Core™ fiber types.

What is the operating temperature range for these patch cords?

The operating and installation temperature range is -10°C to 60°C (14°F to 140°F).

What is the minimum connector return loss?

The minimum connector return loss is 26dB.

What is the maximum connector insertion loss?

The maximum connector insertion loss is 0.10dB.

Are these patch cords RoHS compliant?

Yes, all patch cord components meet the requirements of Directive 2002/95/EC for Restriction of Hazardous Substances (RoHS) Compliance.

What is the storage temperature range for the patch cords?

The storage and shipping temperature range is -40°C to 70°C (-40°F to 158°F).

What is the connector durability rating?

The connectors have a durability rating of 500 cycles.

What is the minimum bend radius for these patch cords?

The minimum bend radius is 32mm, and the minimum long-term bend radius is 16mm.

What is the outside diameter of the cable?

The cable outside diameter (OD) is 1.6mm for the duplex cable.

What connector types are used on these patch cords?

Both ends of the patch cords use Duplex LC connectors.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.