- FAA-compliant flash rate (45 to 150 FPM) and ON/OFF ratios (50-67% ON time)
- Zero voltage switching extends lamp life up to ten times
- Supports incandescent, resistive, and inductive loads up to 1A steady state
- Rugged encapsulated circuitry with molded-in heat transfer plate for thermal management
- Superior RF filtering circuitry for high RF environments, including AM hot towers
Specifications
Brand Name | Littelfuse |
Color | Blue |
Connection | Removable mounting bracket, use one #8 (M4 x 0.7) screw |
Connection Type | Quick-connect terminals |
Current Rating | 1 A |
Material | Plastic |
Mounting | Removable mounting bracket, use one #8 (M4 x 0.7) screw Mount |
Mounting Type | Surface-Mount |
Operating Temperature | -20 to 60 F |
Operating Temperature, Maximum | 60 F |
Operating Temperature, Minimum | -20 F |
Series | FA/FS Series |
Size | 38.1 x 23.9 mm |
Special Features | 10Y WARR |
Standard | CE/UR/CSA |
Sub Brand | SSAC |
Voltage Rating | 120 VAC |

FS146
The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
FA155-2
The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First) FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
PHS230A20
The PHS230A20 relay provides phase control protection with input voltage at 230 V ac and output load rating at steady state (100% on) of 20 A; inrush of 200 A.
SIR2B20B4
The SIR2B20B4 relay provides solid-state switching protection with input voltage from 90 to 150 V ac/dc and output voltage at 120 V ac.
PHS120A10
The PHS120A10 relay provides phase control protection with input voltage at 120 V ac and output load rating at steady state (100% on) of 10 A; inrush of 100 A.
FS165-30T
The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
FS155-30T
The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
FS146RC
The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
FS155-30RF
The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
FS224
The FS200 Series may be used to control inductive, incandescent, or resistive loads. Factory fixed flash rate of 45 or 90 FPM or may be ordered with a fixed custom flash rate ranging from 10 to 180 FPM. Encapsulation provides protection against shock, vibration, and humidity. Uniform performance, high inrush current capability, and low RFI, make this series ideal for general industrial applications. Operation: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until input voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.Frequently Asked Questions about Littelfuse
What certifications and standards do Littelfuse products comply with?
Littelfuse products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Customers can verify specific product certifications by consulting individual product datasheets on Littelfuse.com, which provide comprehensive details about standards compliance for each component.
What industries and applications are Littelfuse products used for?
Littelfuse products are critical for electrical protection and safety across multiple industrial sectors, including manufacturing, automation, power distribution, and electrical control systems. Their comprehensive product portfolio serves industries that require robust electrical protection, including motor and pump applications, solar installations, programmable logic controllers (PLCs), electrical switch panels, and critical infrastructure environments. Key product lines protect against overcurrent, voltage transients, ground faults, and temperature-related electrical risks, ensuring equipment safety and operational reliability.
What technical support does Littelfuse offer?
Littelfuse offers comprehensive technical support through multiple channels. Their Technical Hotline (800-TEC-FUSE) provides direct access to engineers who can help identify issues and recommend solutions. Additionally, Littelfuse offers extensive online Technical Resources at Littelfuse.com, including datasheets, product manuals, whitepapers, application guides, and online design tools. Their experienced product and application engineers also provide step-by-step support from design to installation.
What are the main product lines offered by Littelfuse?
Littelfuse offers comprehensive industrial protection and control product lines, including fuses, fuse holders, protection relays, temperature sensors, and electrical safety components. Their key product categories span surge protective devices, custom OEM products, electrical switch panels, medium voltage fuses, ground-fault protection relays, motor and pump protection devices, and temperature sensors. These products are designed to minimize electrical safety hazards, limit equipment damage, improve productivity, and safeguard personnel from electrical faults.
What are the key features of Littelfuse products?
Littelfuse products feature exceptional circuit protection technologies with key characteristics including UL/IEC safety standard compliance, low internal resistance, and advanced protective capabilities across multiple product lines. Their components provide critical protection for industrial systems, offering features like overcurrent protection, voltage transient suppression, and resettable protection devices with ultra-low resistance and compact designs. Key product lines include fuses, metal oxide varistors (MOVs), TVS diodes, PolySwitch devices, and specialized electronic protection components that enhance system reliability and safety.
What environmental ratings do Littelfuse products have?
Littelfuse products feature comprehensive environmental ratings, including NEMA Type 1, 2, 3, 3R, 4/4X, 12, and 13 certifications, as well as IP65 protection. These ratings ensure superior protection in diverse industrial environments, with an operating temperature range of -40°F to +131°F (-40°C to +55°C). Many products also include UV-stabilized materials and neoprene gaskets for enhanced durability in outdoor and challenging conditions.
What accessories are available for Littelfuse products?
Littelfuse offers several key accessories across their product lines, including fuse holders, voltage monitoring modules, and terminal connectors. Specific accessories include the LPSM003ZXID (indicating) and LPSM003Z (non-indicating) POWR-SAFE Dead Front fuse holders for Class CC and Midget-Style fuses, the VRM6048 voltage monitor accessory module, and female quick connect terminals (P1015 series) in various wire gauge sizes. These accessories are designed to enhance protection, monitoring, and connectivity for Littelfuse electrical components.
What is Littelfuse's warranty policy?
Littelfuse provides comprehensive warranty details on their official website at www.littelfuse.com/warranty. Customers should visit this page to review the specific warranty terms and conditions for their specific product lines. For direct warranty support or questions, customers can contact Littelfuse Technical Support at 1-800-TEC-FUSE or email [email protected].
What communication protocols do Littelfuse products support?
Littelfuse supports a comprehensive range of industrial communication protocols, including PROFIBUS, PROFINET, EtherNet/IP, DeviceNet, Modbus RTU, and CANopen. Our products provide flexible connectivity solutions across multiple industrial automation platforms, enabling seamless integration with various control systems and network architectures.
How are Littelfuse products typically installed?
Littelfuse products are typically installed using specialized mounting hardware like fuse holders, blocks, and panels designed for specific industrial applications. The POWR-SAFE Dead Front holders, for example, provide optimum protection for Class CC and Midget-Style fuses, supporting installations up to 600 VAC/DC. Installation often involves using precision terminals with strain relief, such as 0.25 in. female quick connect terminals, to ensure secure and safe electrical connections in industrial control systems.