Hammond Power SK3A0015KK3K - 600V Class Three Phase DOE2016 and NRCan 2019 Compliant Energy Efficient K-Factor Transformer, K-Factor 13, 480D PV, 480Y/277 SV, 15 kVA, Three Phase, Copper Wound, Shielded
Hammond Power

SK3A0015KK3K

UPC: 803423130619


Documents & Media
BrochureSpecification Sheet

Contact for Pricing

Overview

The Hammond Power Solutions (HPS) SK3A0015KK3K is a 600V class, three-phase K-Factor 13 transformer designed to meet DOE2016 and NRCan 2019 energy efficiency standards. Rated at 15 kVA, this transformer features a 480D primary voltage and 480Y/277V secondary voltage, making it ideal for applications with non-linear loads such as variable frequency drives (VFDs), UPS systems, and other harmonic-generating equipment. Constructed with copper windings and a shielded design, the SK3A0015KK3K provides superior thermal performance and reduced electromagnetic interference (EMI). Its K-Factor 13 rating ensures reliable operation in environments with high harmonic distortion, preventing overheating and extending equipment lifespan. The transformer is UL listed and CSA certified, guaranteeing compliance with North American safety standards. Suitable for indoor installations, this transformer is manufactured in the US and backed by Hammond Power Solutions' reputation for quality and reliability. With a compact footprint and durable construction, it is a cost-effective solution for modern industrial and commercial power distribution systems.
  • Specifically designed to handle the harmonics generated by non-linear loads such as computer and telecommunication equipment, drives and other power electronics
  • Meets North American Efficiency Standards: U.S. - DOE 10 CFR Part 431 (DOE 2016); Canada - SOR/2018-201, (NRCan 2019) & ON Reg. 404/12;  Mexico - NMX-J-351-ANCE-2021
  • Standard three phase voltage groups available at k-factor ratings of K4, K9, K13
  • Copper wound and shielded construction for enhanced durability
  • UL listed and CSA certified for safety and reliability

Specifications

Application
Addresses the overheating problems due to harmonics associated with non-linear loads where drives, personal computers, telecommunications equipment, broadcasting equipment and other similar power electronics are found in high concentrations.
Cable Entry
Side knock-outs standard on all units
Connection Type
Delta-Wye
Connection Type
Wye/Delta
Cooling
Convection cooled
Depth
20.13 IN
Enclosure
DH1-N3R - Indoor or Outdoor
Enclosure Color
ANSI 61 Grey
Enclosure Type
3R
Frequency
60 Hz
Frequency Rating
60 HZ
Height
22 in
KVA Rating
15 KVA
Length
20.13 in
Material
Copper Wound, Shielded
Material
Copper
Mounting
Floor or Wall/Ceiling Mount
Mounting Method
Floor
Mounting Type
Shielded
Number Of Phases
3
Number Of Taps
ST-20 compliant
Phase
A - 3PH Delta-Wye-N
Phase
3PH
Poles
3P
Poles
3PH
Poles
Three Phase
Primary Voltage
480 VAC
Primary Voltage
480D V
Secondary Voltage
480Y/277V
Series
DOE2016/NRCan 2019 Compliant Energy Efficient K-Factor
Series
SK3A
Size
15 kVA
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets current DOE 10 CFR part 431 (2016) and C802.2 efficiencies in an outdoor type enclosure. Smaller kVA sizes have standard input and/or output lugs, knockouts, and wall mounting brackets to save installation costs.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150
Transformer Rating
15kVA
Type
Transformer > Distribution > DOE 2016 Energy Efficient > K Factor > Three Phase
Voltage Rating
480 VAC
Wall Mounting
Yes
Warranty
10 year warranty
Weight
240 lbs
Width
21.5 in
Winding
K - CU + Shield
Winding
CU
Package Dimensions (L x W x H)
20.13 IN x 21.5 IN x 22 IN
Package Dimensions (L x W x H)
51.1302 cm x 54.61 cm x 55.88 cm
Package Weight (Imperial)
240.000 L
Package Weight (Metric)
108.864 kg
A - 15.0 kV bushing

015J0400AN

A - 15.0 kV bushing
O Plus C - 34.5 kV bushing

034Z3000AW

O Plus C - 34.5 kV bushing

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.