Hammond Power CP1P6G0335CC - Passive Harmonic Filters, 350 HorsePower, 600 Volts, 335 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Hammond Power

CP1P6G0335CC

UPC: 803423190743


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power CP1P6G0335CC is a passive harmonic filter designed for industrial applications requiring robust harmonic mitigation. This unit is rated for 350 HorsePower, operates at 600 Volts, and can handle up to 335 Amperes at a frequency of 60 Hertz. Its enclosure is Type 3R, suitable for outdoor or indoor use where protection against falling rain and sleet is necessary. The integrated contactor simplifies installation and control. This advanced HPS design significantly reduces harmonic current distortion, typically achieving 80% reduction, bringing distortion levels to 5% or less at full load. It also corrects the true power factor to over 95%, ensuring efficient power utilization. The CP1P6G0335CC is engineered to meet IEEE 519 harmonic requirements when operated within its designed parameters, making it an ideal solution for environments with significant non-linear loads such as VFDs, UPS systems, and switching power supplies. Its construction ensures reliable performance and longevity in demanding industrial settings. The UNSPSC code for this product is 83101808, and it is manufactured in the USA.
  • The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
  • It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
  • HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
  • Typical Power Factor: >95%
  • Type 3R enclosure for outdoor/indoor use
  • Reduces harmonic current distortion by up to 80%
  • Corrects true power factor to over 95%
  • Meets IEEE 519 harmonic requirements
  • Integrated contactor for simplified control
  • Manufactured in the USA

Specifications

Ambient Operating Temperature
0 to 40 Deg C
Application
For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants
Cooling
Natural Convection
Depth
21 IN
Enclosure
Type 3R DH5
Enclosure Type
Type 3R
Frequency
60Hz
Frequency Rating
60 HZ
Height
33.6 IN
Impedance
335A
Input Current
315 A
Length
34 in
Mounting
Floor Mount
Mounting Style
Floor
Output Current
335 A
Special Features
Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements.
Standard
cUL Listed (E61431)
Voltage
600 V
Voltage Rating
600V
Warranty
3 Years
Weight
1300 L
Width
17 IN
Package Dimensions (L x W x H)
21 IN x 17 IN x 33.6 IN
Package Dimensions (L x W x H)
533.4 mm x 431.8 mm x 853.44 mm
Package Weight (Imperial)
1300.000 L
Package Weight (Metric)
590.000 kg
Passive Harmonic Filters, 300 HorsePower, 600 Volts, 287 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0287CC

Passive Harmonic Filters, 300 HorsePower, 600 Volts, 287 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 250 HorsePower, 600 Volts, 240 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0240CC

Passive Harmonic Filters, 250 HorsePower, 600 Volts, 240 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 400 HorsePower, 600 Volts, 399 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0399CC

Passive Harmonic Filters, 400 HorsePower, 600 Volts, 399 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 200 HorsePower, 600 Volts, 192 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0192CC

Passive Harmonic Filters, 200 HorsePower, 600 Volts, 192 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 350 HorsePower, 480 Volts, 420 Amperes, 60 Hertz, Open Style

CP1K6G0420F

Passive Harmonic Filters, 350 HorsePower, 480 Volts, 420 Amperes, 60 Hertz, Open Style
Passive Harmonic Filters, 500 HorsePower, 600 Volts, 505 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0505CC

Passive Harmonic Filters, 500 HorsePower, 600 Volts, 505 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 300 HorsePower, 480 Volts, 358 Amperes, 60 Hertz, Open Style

CP1K6G0358F

Passive Harmonic Filters, 300 HorsePower, 480 Volts, 358 Amperes, 60 Hertz, Open Style
Passive Harmonic Filters, 250 HorsePower, 600 Volts, 240 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0240C

Passive Harmonic Filters, 250 HorsePower, 600 Volts, 240 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 300 HorsePower, 600 Volts, 287 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0287C

Passive Harmonic Filters, 300 HorsePower, 600 Volts, 287 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 125 HorsePower, 600 Volts, 120 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0120C

Passive Harmonic Filters, 125 HorsePower, 600 Volts, 120 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 300 HorsePower, 480 Volts, 358 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0358CC

Passive Harmonic Filters, 300 HorsePower, 480 Volts, 358 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 100 HorsePower, 600 Volts, 96 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0096C

Passive Harmonic Filters, 100 HorsePower, 600 Volts, 96 Amperes, 60 Hertz, Enclosure Type 3R

Frequently Asked Questions

What is the purpose of this passive harmonic filter?

The HPS passive harmonic filter improves power quality by reducing harmonic current distortion by 80% (typically to 5% or less at full load) and correcting true power factor to over 95%. It is designed to mitigate harmonics from non-linear loads like variable frequency drives (VFDs).

What voltage ratings are available for this filter?

The passive harmonic filter is available in two voltage ratings: 480VAC (+/-10%) and 600VAC (+/-10%). Current ratings range from 6A to 632A, covering 5 to 500 horsepower applications.

What is the warranty for this product?

The passive harmonic filter comes with a 3-year warranty.

What are the operating temperature requirements?

The filter has an ambient operating temperature range up to 50°C, with a maximum humidity of 95% non-condensing. Storage temperature is -20°C to +60°C.

What harmonics does this filter mitigate?

The HPS passive harmonic filter is engineered to reduce the 5th, 7th, 11th, 13th, and higher order harmonics in three-phase power systems.

What are the potential consequences of harmonic distortion?

Harmonic distortion can cause overheating of electrical equipment, loss of efficiency, nuisance tripping, premature equipment failure, and interference with communication systems.

How does the filter improve power system efficiency?

By mitigating harmonics and correcting power factor, the filter lowers kW and kVA, typically reducing total harmonic current distortion from 30-60% to 5% or less, and improving power factor to over 95%.

What industries benefit from this harmonic filter?

Critical industries include chemical processing, data centers, HVAC systems, material handling, mining, oil & gas, pulp & paper, hospitals, wastewater treatment plants, and EV charging.

Is this filter compatible with generators?

Yes, the filter is generator compatible. Its kVAr ratings are limited to no more than 20% of the filter's kVA, which ensures compatibility with generator-fed systems.

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Grounding wire

  1. Inspect the unit

    Immediately after receiving the Passive Harmonic Filter, inspect it for any transit damage and verify against the shipping documents. If any damage is noted, file a claim with the carrier.

  2. Mount the filter

    Secure the HPS Centurion P Passive Harmonic Filter to a stable surface using the provided mounting screws. Ensure it is positioned to allow for adequate ventilation and access.

  3. Connect the wiring

    Connect the power supply to terminals A1, B1, and C1 for phases A, B, and C respectively. Connect the load to terminals A2, B2, and C2. Ensure all connections are tight and secure.

  4. Ground the filter

    Connect a grounding wire to the designated grounding location on the filter. Ensure that the grounding connection is secure to prevent electric shock.

  5. Verify connections

    Use a multimeter to verify that all connections are correct and that there is no voltage present before energizing the unit. Confirm that the grounding is intact.

  6. Energize the filter

    Once all connections are verified, turn on the power supply to the HPS Centurion P Passive Harmonic Filter. Monitor for any unusual sounds or indicators.

  7. Perform initial testing

    Use a power quality analyzer to measure total harmonic distortion and power factor before and after connecting the filter to establish a baseline for performance.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.