Hammond Power CP1P6G0016CC - Passive Harmonic Filters, 15 HorsePower, 600 Volts, 16 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Hammond Power

CP1P6G0016CC

UPC: 803423190460


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power Passive Harmonic Filter, SKU CP1P6G0016CC, is a 15 Horsepower, 600 Volt, 16 Ampere unit designed to mitigate harmonic distortion in industrial power systems. Operating at 60 Hertz, this passive harmonic filter reduces harmonic current distortion by up to 80%, typically bringing it to 5% or less at full load. It delivers a true power factor exceeding 95%, ensuring compliance with IEEE 519 harmonic requirements when used within specified parameters. The unit features an Enclosure Type 3R for robust protection against environmental conditions. Its advanced design surpasses traditional harmonic filters by providing measurable improvements in power quality and system efficiency. The inclusion of a contactor simplifies integration into existing electrical control panels. Manufactured in the USA, the CP1P6G0016CC is a reliable solution for applications requiring clean power and adherence to harmonic standards.
  • The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
  • It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
  • HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
  • Typical Power Factor: >95%
  • Enclosure Type 3R for robust environmental protection with integrated contactor

Specifications

Ambient Operating Temperature
0 to 40 Deg C
Application
For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants
Cooling
Natural Convection
Current Rating
16 Amperes
Current Rating
16 A
Depth
9.8 IN
Enclosure
Type 3R DH1
Enclosure Type
Type 3R
Frequency
60Hz
Frequency
60 Hertz
Frequency Rating
60 HZ
Height
15.2 IN
Impedance
16A
Input Current
14 A
Length
20.1 in
Mounting
Wall/Ceiling/Floor Mount
Mounting Style
Floor
NEMA Rating
Type 3R
Output Current
16 A
Series
CP1P
Special Features
Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements.
Standard
cUL Listed (E61431)
Voltage
600 V
Voltage Rating
600 Volts
Voltage Rating
600V
Voltage Rating
600 V
Warranty
3 Years
Weight
70 L
Width
8.8 IN
Package Dimensions (L x W x H)
9.8 IN x 8.8 IN x 15.2 IN
Package Dimensions (L x W x H)
249 mm x 224 mm x 386 mm
Package Weight (Imperial)
70.000 L
Package Weight (Metric)
32.000 kg
Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0012CC

Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 20 HorsePower, 600 Volts, 20 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0020CC

Passive Harmonic Filters, 20 HorsePower, 600 Volts, 20 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 25 HorsePower, 600 Volts, 25 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0025CC

Passive Harmonic Filters, 25 HorsePower, 600 Volts, 25 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0008CC

Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0006CC

Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 30 HorsePower, 600 Volts, 31 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0031CC

Passive Harmonic Filters, 30 HorsePower, 600 Volts, 31 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 40 HorsePower, 600 Volts, 40 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0040CC

Passive Harmonic Filters, 40 HorsePower, 600 Volts, 40 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 15 HorsePower, 600 Volts, 16 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0016C

Passive Harmonic Filters, 15 HorsePower, 600 Volts, 16 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0012C

Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 50 HorsePower, 600 Volts, 49 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0049CC

Passive Harmonic Filters, 50 HorsePower, 600 Volts, 49 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 15 HorsePower, 480 Volts, 19 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0019C

Passive Harmonic Filters, 15 HorsePower, 480 Volts, 19 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 25 HorsePower, 600 Volts, 25 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0025C

Passive Harmonic Filters, 25 HorsePower, 600 Volts, 25 Amperes, 60 Hertz, Enclosure Type 3R

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring proper wiring and configuration.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the unit

    Immediately after receiving the Passive Harmonic Filter, inspect it for any transit damage and ensure all parts are included as per the packing list.

  2. Mount the filter

    Secure the HPS Centurion P Passive Harmonic Filter to a stable surface, ensuring it is positioned for proper ventilation and accessibility. Maintain at least 6 inches of clearance around the unit.

  3. Connect the wiring

    Connect the input power supply to terminals A1, B1, and C1, and connect the load to terminals A2, B2, and C2. Ensure all connections are tight and comply with local electrical codes.

  4. Ground the unit

    Properly ground the Passive Harmonic Filter using the designated grounding location to ensure safe operation before energizing the unit.

  5. Power on and test

    Turn on the power supply to the filter and use a multimeter to verify that the input voltage is within 5% of the nameplate voltage. Ensure all indicators are functioning correctly.

  6. Perform initial calibration

    Use a power quality analyzer to measure baseline parameters such as total harmonic distortion and power factor before and after connecting the filter to assess its performance.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.