Hammond Power CP1P6G0008CC - Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Hammond Power

CP1P6G0008CC

UPC: 803423190422


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power CP1P6G0008CC Passive Harmonic Filter (SKU: CP1P6G0008CC) is engineered to mitigate harmonic distortion in industrial electrical systems. This advanced HPS design significantly outperforms traditional harmonic filters, typically reducing harmonic current distortion by 80%, bringing it to 5% or less at full load. It also corrects the true power factor to over 95%, ensuring efficient energy utilization. Crucially, this filter is designed to meet IEEE 519 harmonic requirements when operated within its specified parameters. Featuring a 7.5 HorsePower rating, 600 Volts operating voltage, and an 8 Ampere current capacity, it is suitable for 60 Hertz applications. The enclosure is rated Type 3R, providing protection against falling rain and sleet, making it suitable for outdoor or exposed installations. This model includes a contactor for integrated control. Manufactured in the US, the CP1P6G0008CC is a reliable solution for maintaining power quality and system efficiency in demanding industrial environments.
  • The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
  • It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
  • HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
  • Typical Power Factor: >95%
  • Type 3R enclosure for outdoor/exposed installations

Specifications

Ambient Operating Temperature
0 to 40 Deg C
Application
For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants
Cooling
Natural Convection
Depth
7.5 IN
Enclosure
Type 3R DH1
Enclosure Type
Type 3R
Frequency
60Hz
Frequency Rating
60 HZ
Height
12.5 IN
Impedance
8A
Input Current
7 A
Length
20.1 in
Mounting
Wall/Ceiling/Floor Mount
Mounting Style
Floor
Output Current
8 A
Special Features
Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements.
Standard
cUL Listed (E61431)
Voltage
600 V
Voltage Rating
600V
Warranty
3 Years
Weight
50 L
Width
7.7 IN
Package Dimensions (L x W x H)
7.5 IN x 7.7 IN x 12.5 IN
Package Dimensions (L x W x H)
191 mm x 196 mm x 318 mm
Package Weight (Imperial)
50.000 L
Package Weight (Metric)
23.000 kg
Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0006CC

Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 15 HorsePower, 600 Volts, 16 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0016CC

Passive Harmonic Filters, 15 HorsePower, 600 Volts, 16 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0012CC

Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 20 HorsePower, 600 Volts, 20 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0020CC

Passive Harmonic Filters, 20 HorsePower, 600 Volts, 20 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 25 HorsePower, 600 Volts, 25 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0025CC

Passive Harmonic Filters, 25 HorsePower, 600 Volts, 25 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 30 HorsePower, 600 Volts, 31 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0031CC

Passive Harmonic Filters, 30 HorsePower, 600 Volts, 31 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 40 HorsePower, 600 Volts, 40 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0040CC

Passive Harmonic Filters, 40 HorsePower, 600 Volts, 40 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0008C

Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0006C

Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0012C

Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 5 HorsePower, 480 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0008CC

Passive Harmonic Filters, 5 HorsePower, 480 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 7.5 HorsePower, 480 Volts, 11 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0011CC

Passive Harmonic Filters, 7.5 HorsePower, 480 Volts, 11 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

Frequently Asked Questions

What is the purpose of this passive harmonic filter?

The HPS passive harmonic filter improves power quality by reducing harmonic current distortion by 80% (typically to 5% or less at full load) and correcting true power factor to over 95%.

What voltage ratings are available for this filter?

The filter is available in 480VAC and 600VAC ratings, with a +/-10% voltage range. Current ratings vary from 6A to 632A, covering 5 to 500 horsepower applications.

What are the operating temperature requirements?

The filter can operate in ambient temperatures up to 50°C, with a storage temperature range of -20°C to +60°C. Thermal characteristics vary by current rating, with 130°C temperature rise for 2A-54A units and 180°C for units over 55A.

What types of harmonics does this filter mitigate?

The filter is engineered to reduce 5th, 7th, 11th, 13th, and higher order harmonics in three-phase power systems, particularly those caused by non-linear loads like variable frequency drives (VFDs).

What are the key performance characteristics?

The filter offers over 95% power factor, no less than 99% efficiency at full load, 150% overload capability for 1 minute, and is engineered to avoid resonance.

What industries benefit from this harmonic filter?

Critical applications in industries such as chemical processing, data centers, HVAC systems, material handling, mining, oil & gas, pulp & paper, hospitals, wastewater treatment plants, and EV charging can benefit from this filter.

What mounting options are available?

The filter comes in open (wall) and enclosed (Type 3R) styles, with wall and floor mounting options. Optional mounting kits are available for wall and ceiling mounting for some enclosure styles.

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Grounding wire

  1. Inspect the unit

    Immediately after receiving the Passive Harmonic Filter, inspect it for any transit damage and verify against the shipping documents. If any damage is noted, file a claim with the carrier.

  2. Mount the filter

    Secure the HPS Centurion P Passive Harmonic Filter to a stable surface using the provided mounting brackets and screws. Ensure it is positioned to allow for adequate ventilation and accessibility.

  3. Connect the wiring

    Connect the input and output wiring according to the nameplate diagram. Ensure A1, B1, C1 are connected to the power supply phases, and A2, B2, C2 are connected to the load phases. Use terminal connectors for secure connections.

  4. Ground the filter

    Properly ground the Passive Harmonic Filter using the designated grounding location. Ensure all ground connections are tight and secure.

  5. Verify connections

    Before energizing, use a multimeter to verify that all connections are correct and that there is no voltage present. Confirm that all terminals are properly tightened.

  6. Energize the filter

    Once all connections are verified, energize the filter by turning on the upstream circuit breaker. Monitor for any unusual sounds or indicators.

  7. Perform initial testing

    Use a power quality analyzer to measure the performance of the filter. Record baseline readings for total harmonic distortion and power factor before and after installation.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.