Overview

The Hammond Power Passive Harmonic Filter, SKU CP1P6G0006CC, is engineered to mitigate harmonic distortion in industrial electrical systems. This unit is rated for 5 Horsepower, operates at 600 Volts, and handles a continuous current of 6 Amperes at 60 Hertz. Its robust Type 3R enclosure provides protection suitable for outdoor or indoor installations where exposure to weather is a concern. The advanced HPS design significantly reduces harmonic current distortion, typically achieving an 80% reduction, bringing distortion levels to 5% or less at full load. This performance ensures compliance with IEEE 519 harmonic standards when operated within its designed parameters. Furthermore, the filter corrects the true power factor to over 95%, enhancing overall system efficiency and reducing energy costs. Manufactured in the USA, this passive harmonic filter is a reliable solution for protecting sensitive equipment and improving power quality in demanding industrial environments. Its inclusion of a contactor simplifies integration into existing control systems.
  • The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
  • It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
  • HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
  • Typical Power Factor: >95%
  • Includes integrated contactor for easy installation
  • Integrated contactor for simplified installation
  • Reduces harmonic current distortion by up to 80%
  • Corrects true power factor to over 95%
  • Meets IEEE 519 harmonic requirements

Specifications

Ambient Operating Temperature
0 to 40 Deg C
Application
For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants
Cooling
Natural Convection
Current Rating
6 A
Depth
7.5 IN
Enclosure
Type 3R DH1
Enclosure Type
Type 3R
Frequency
60Hz
Frequency Rating
60 HZ
Height
12.5 IN
Impedance
6A
Input Current
5 A
Length
20.1 in
Mounting
Wall/Ceiling/Floor Mount
Mounting Style
Floor
NEMA Rating
Type 3R
Output Current
6 A
Series
CP1P6G
Special Features
Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements.
Standard
cUL Listed (E61431)
Voltage
600 V
Voltage Rating
600 V
Voltage Rating
600V
Warranty
3 Years
Weight
45 L
Width
7.7 IN
Package Dimensions (L x W x H)
7.5 IN x 7.7 IN x 12.5 IN
Package Dimensions (L x W x H)
191 mm x 196 mm x 318 mm
Package Weight (Imperial)
45.000 L
Package Weight (Metric)
20.000 kg
Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0008CC

Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 15 HorsePower, 600 Volts, 16 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0016CC

Passive Harmonic Filters, 15 HorsePower, 600 Volts, 16 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0012CC

Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 25 HorsePower, 600 Volts, 25 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0025CC

Passive Harmonic Filters, 25 HorsePower, 600 Volts, 25 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 20 HorsePower, 600 Volts, 20 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0020CC

Passive Harmonic Filters, 20 HorsePower, 600 Volts, 20 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0008C

Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0006C

Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 5 HorsePower 480V 8 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0008C

Passive Harmonic Filters, 5 HorsePower 480V 8 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 7.5 HorsePower, 480 Volts, 11 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0011CC

Passive Harmonic Filters, 7.5 HorsePower, 480 Volts, 11 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 7.5 HorsePower, 480 Volts, 11 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0011C

Passive Harmonic Filters, 7.5 HorsePower, 480 Volts, 11 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 5 HorsePower, 480 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0008CC

Passive Harmonic Filters, 5 HorsePower, 480 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 10 HorsePower, 480 Volts, 14 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0014CC

Passive Harmonic Filters, 10 HorsePower, 480 Volts, 14 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter, Forklift

Supplies needed:

Mounting screws, Terminal connectors, Grounding wire

  1. Inspect the unit

    Immediately after receiving the Passive Harmonic Filter, inspect it for any transit damage and verify it against the shipping documents. If any damage is noted, file a claim with the carrier.

  2. Mount the filter

    Using a forklift, carefully lift and position the filter in the designated installation location, ensuring it is at least 6 inches away from walls and other obstructions for proper ventilation.

  3. Ground the filter

    Connect the designated main grounding location of the filter to a proper ground to ensure safe operation before energizing the unit.

  4. Connect the wiring

    Connect the power supply to the filter by wiring phases A1, B1, and C1 to the corresponding phases of the power supply, and A2, B2, and C2 to the load. Ensure all connections are tight and secure.

  5. Verify connections

    Use a multimeter to check all electrical connections for continuity and proper voltage levels before energizing the filter.

  6. Energize the filter

    Once all connections are verified, turn on the upstream circuit breaker or disconnect to energize the filter. Monitor for any unusual sounds or indicators.

  7. Perform initial testing

    After energizing, use a power quality analyzer to measure total harmonic distortion and power factor to establish a baseline for performance.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.