Hammond Power CP1K6G0358CC - Passive Harmonic Filters, 300 HorsePower, 480 Volts, 358 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Hammond Power

CP1K6G0358CC

UPC: 803423190323


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power Passive Harmonic Filter, SKU CP1K6G0358CC, is engineered to significantly mitigate harmonic distortion in industrial electrical systems. Designed for 300 HorsePower applications operating at 480 Volts and 358 Amperes with a 60 Hertz frequency, this filter offers robust performance. Its advanced HPS design typically reduces harmonic current distortion by 80%, bringing it to 5% or less at full load, which is crucial for meeting IEEE 519 harmonic requirements. Beyond harmonic reduction, this filter also corrects the true power factor to over 95%, enhancing overall system efficiency and reducing energy costs. The enclosure is rated Type 3R, providing protection against falling rain and sleet, making it suitable for outdoor or exposed installations. Featuring an integrated contactor, this passive harmonic filter simplifies installation and ensures reliable operation. Manufactured in the USA, it is built to exacting standards for dependable performance in demanding industrial environments. Its UNSPSC code is 83101808.
  • The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
  • It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
  • HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
  • Typical Power Factor: >95%
  • Type 3R enclosure for outdoor/exposed installations

Specifications

Ambient Operating Temperature
0 to 40 Deg C
Application
For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants
Cooling
Natural Convection
Current Rating
358 A
Depth
29.5 IN
Enclosure
Type 3R DH5
Enclosure Type
Type 3R
Frequency
60Hz
Frequency Rating
60 HZ
Height
44.5 IN
Impedance
358A
Input Current
337 A
Length
34 in
Mounting
Floor Mount
Mounting Style
Floor
NEMA Rating
Type 3R
Output Current
358 A
Special Features
Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements.
Standard
cUL Listed (E61431)
Voltage
480 V
Voltage Rating
480 V
Voltage Rating
480V
Warranty
3 Years
Weight
1400 L
Width
31.5 IN
Package Dimensions (L x W x H)
29.5 IN x 31.5 IN x 44.5 IN
Package Dimensions (L x W x H)
749 mm x 800 mm x 1130 mm
Package Weight (Imperial)
1400.000 L
Package Weight (Metric)
635.000 kg
Passive Harmonic Filters, 300 HorsePower, 480 Volts, 358 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0358C

Passive Harmonic Filters, 300 HorsePower, 480 Volts, 358 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 250 HorsePower, 480 Volts, 299 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0299CC

Passive Harmonic Filters, 250 HorsePower, 480 Volts, 299 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 250 HorsePower, 480 Volts, 299 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0299C

Passive Harmonic Filters, 250 HorsePower, 480 Volts, 299 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 300 HorsePower, 600 Volts, 287 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0287C

Passive Harmonic Filters, 300 HorsePower, 600 Volts, 287 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 350 HorsePower, 480 Volts, 420 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0420CC

Passive Harmonic Filters, 350 HorsePower, 480 Volts, 420 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 350 HorsePower, 480 Volts, 420 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0420C

Passive Harmonic Filters, 350 HorsePower, 480 Volts, 420 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 200 HorsePower, 480 Volts, 241 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0241CC

Passive Harmonic Filters, 200 HorsePower, 480 Volts, 241 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 200 HorsePower, 480 Volts, 241 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0241C

Passive Harmonic Filters, 200 HorsePower, 480 Volts, 241 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 250 HorsePower, 600 Volts, 240 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0240C

Passive Harmonic Filters, 250 HorsePower, 600 Volts, 240 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 150 HorsePower, 480 Volts, 180 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0180C

Passive Harmonic Filters, 150 HorsePower, 480 Volts, 180 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 200 HorsePower, 600 Volts, 192 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0192C

Passive Harmonic Filters, 200 HorsePower, 600 Volts, 192 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 150 HorsePower, 480 Volts, 180 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0180CC

Passive Harmonic Filters, 150 HorsePower, 480 Volts, 180 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Grounding wire

  1. Inspect the unit

    Immediately after receiving the Passive Harmonic Filter, inspect it for any transit damage and verify against the shipping documents. If any damage is noted, file a claim with the carrier.

  2. Mount the filter

    Secure the HPS Centurion P Passive Harmonic Filter to a stable surface using the provided mounting brackets and screws. Ensure there is adequate clearance for ventilation and access.

  3. Ground the filter

    Connect the designated main grounding location of the filter to a suitable ground. Ensure that all ground connections are tight and secure before proceeding.

  4. Connect the wiring

    Connect the input and output wiring to the filter according to the nameplate diagram. Ensure that A1, B1, and C1 are connected to the power supply phases, and A2, B2, and C2 are connected to the load phases.

  5. Verify connections

    Use a multimeter to verify that all connections are secure and that there is no voltage present before energizing the system. Ensure that all terminals are properly tightened.

  6. Energize the filter

    Once all connections are verified, turn on the upstream circuit breaker or disconnect to energize the HPS Centurion P Passive Harmonic Filter. Monitor for any unusual sounds or indicators.

  7. Perform initial testing

    Use a power quality analyzer to measure the total harmonic voltage distortion and current distortion before and after connecting the filter to establish a baseline for performance.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.