Hammond Power CP1K6G0180CC - Passive Harmonic Filters, 150 HorsePower, 480 Volts, 180 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Hammond Power

CP1K6G0180CC

UPC: 803423190279


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power Passive Harmonic Filter, SKU CP1K6G0180CC, is engineered to significantly mitigate harmonic distortion in industrial electrical systems. Designed for 150 HorsePower (HP) applications operating at 480 Volts (V) and 60 Hertz (Hz), this filter handles a substantial current rating of 180 Amperes (A). Its advanced HPS design offers superior performance over traditional harmonic filters, typically reducing harmonic current distortion by 80%, bringing it to 5% or less at full load. This level of harmonic reduction ensures compliance with stringent IEEE 519 harmonic requirements when operated within its designed parameters. Furthermore, the filter corrects the true power factor to over 95%, enhancing system efficiency and reducing energy costs. The robust Type 3R enclosure provides protection against environmental factors, making it suitable for various industrial settings. Equipped with a contactor for integrated control, this passive harmonic filter from Hammond Power is a reliable solution for maintaining power quality and system integrity. Manufactured in the US.
  • The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
  • It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
  • HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
  • Typical Power Factor: >95%
  • Type 3R enclosure for environmental protection
  • Integrated contactor
  • Reduces harmonic current distortion by 80% (typically to 5% or less)
  • Corrects true power factor to over 95%
  • Meets IEEE 519 harmonic requirements

Specifications

Ambient Operating Temperature
0 to 40 Deg C
Application
For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants
Cooling
Natural Convection
Depth
29.5 IN
Enclosure
Type 3R DH3
Enclosure Type
Type 3R
Frequency
60Hz
Frequency Rating
60 HZ
Height
44.5 IN
Impedance
180A
Input Current
169 A
Length
27 IN
Mounting
Floor Mount
Mounting Style
Floor
Output Current
180 A
Special Features
Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements.
Standard
cUL Listed (E61431)
Voltage
480 V
Voltage Rating
480V
Warranty
3 Years
Weight
800 L
Width
31.5 IN
Package Dimensions (L x W x H)
29.5 IN x 31.5 IN x 44.5 IN
Package Dimensions (L x W x H)
749 mm x 800 mm x 1130 mm
Package Weight (Imperial)
800.000 L
Package Weight (Metric)
363.000 kg
Passive Harmonic Filters, 150 HorsePower, 480 Volts, 180 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0180C

Passive Harmonic Filters, 150 HorsePower, 480 Volts, 180 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 200 HorsePower, 480 Volts, 241 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0241CC

Passive Harmonic Filters, 200 HorsePower, 480 Volts, 241 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 200 HorsePower, 480 Volts, 241 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0241C

Passive Harmonic Filters, 200 HorsePower, 480 Volts, 241 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 150 HorsePower, 600 Volts, 144 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0144C

Passive Harmonic Filters, 150 HorsePower, 600 Volts, 144 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 125 HorsePower, 480 Volts, 151 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0151CC

Passive Harmonic Filters, 125 HorsePower, 480 Volts, 151 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 125 HorsePower, 480 Volts, 151 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0151C

Passive Harmonic Filters, 125 HorsePower, 480 Volts, 151 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 100 HorsePower, 480 Volts, 121 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0121CC

Passive Harmonic Filters, 100 HorsePower, 480 Volts, 121 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 100 HorsePower, 480 Volts, 121 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0121C

Passive Harmonic Filters, 100 HorsePower, 480 Volts, 121 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 250 HorsePower, 480 Volts, 299 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0299CC

Passive Harmonic Filters, 250 HorsePower, 480 Volts, 299 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 250 HorsePower, 480 Volts, 299 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0299C

Passive Harmonic Filters, 250 HorsePower, 480 Volts, 299 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 300 HorsePower, 480 Volts, 358 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0358C

Passive Harmonic Filters, 300 HorsePower, 480 Volts, 358 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 125 HorsePower, 600 Volts, 120 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0120C

Passive Harmonic Filters, 125 HorsePower, 600 Volts, 120 Amperes, 60 Hertz, Enclosure Type 3R

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Grounding wire

  1. Inspect the unit

    Check the HPS Centurion P Passive Harmonic Filter for any transit damage and ensure all components are present according to the shipping documents.

  2. Mount the filter

    Secure the filter to a suitable location, ensuring it is accessible and has at least 6 inches of clearance on all sides for ventilation.

  3. Ground the filter

    Connect the designated main grounding location of the filter to a proper ground to ensure safe operation before energizing.

  4. Wire the connections

    Connect the input and output terminals (A1, B1, C1 for input and A2, B2, C2 for output) to the corresponding phases of the power supply and load, following local electrical codes.

  5. Verify connections

    Use a multimeter to check that all connections are secure and that there is no voltage present before proceeding.

  6. Energize the filter

    Turn on the power supply to the filter and check for any abnormal sounds or indicators that may suggest an issue.

  7. Perform initial testing

    Use a power quality analyzer to measure the total harmonic distortion and power factor before and after connecting the filter to establish a baseline.

  8. Document results

    Record the measurements taken during testing to compare against future performance and ensure the filter is operating effectively.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.