Hammond Power CP1K6G0121FC - Passive Harmonic Filters, 100 HorsePower, 480 Volts, 121 Amperes, 60 Hertz, Open Style, Contactor
Hammond Power

CP1K6G0121FC

UPC: 803423190248


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power CP1K6G0121FC is a passive harmonic filter designed to mitigate harmonic distortion in industrial electrical systems. This open-style unit, featuring a contactor, is rated for 100 HorsePower, operates at 480 Volts, and handles a current of 121 Amperes at 60 Hertz. Its advanced HPS design significantly reduces harmonic current distortion, typically achieving 80% reduction and bringing distortion levels to 5% or less at full load. This performance ensures compliance with IEEE 519 harmonic requirements when operated within its designed parameters. Beyond harmonic reduction, the CP1K6G0121FC also corrects the true power factor to over 95%, contributing to improved system efficiency and reduced energy costs. Manufactured in the USA, this filter is a reliable solution for applications requiring clean power and adherence to stringent harmonic standards. Its robust construction and precise engineering make it suitable for demanding industrial environments where power quality is critical. The SKU for this unit is CP1K6G0121FC. The UNSPSC code is 83101808.
  • The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
  • It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
  • HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
  • Typical Power Factor: >95%
  • Open style with integrated contactor

Specifications

Ambient Operating Temperature
0 to 40 Deg C
Application
For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants
Cooling
Natural Convection
Depth
27 IN
Enclosure
Open Frame
Enclosure Type
Open Style
Frequency
60Hz
Frequency Rating
60 HZ
Height
36 IN
Impedance
121A
Input Current
113 A
Length
27 IN
Mounting
Wall/Ceiling/Floor Mount
Mounting Style
Floor
Output Current
121 A
Special Features
Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements.
Standard
cUL Listed (E61431)
Voltage
480 V
Voltage Rating
480V
Warranty
3 Years
Weight
590 L
Width
28.3 IN
Package Dimensions (L x W x H)
27 IN x 28.3 IN x 36 IN
Package Dimensions (L x W x H)
687 mm x 719 mm x 914 mm
Package Weight (Imperial)
590.000 L
Package Weight (Metric)
268.000 kg
Passive Harmonic Filters, 75 HorsePower, 480 Volts, 91 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0091FC

Passive Harmonic Filters, 75 HorsePower, 480 Volts, 91 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 125 HorsePower, 480 Volts, 151 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0151FC

Passive Harmonic Filters, 125 HorsePower, 480 Volts, 151 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 100 HorsePower, 600 Volts, 96 Amperes, 60 Hertz, Open Style, Contactor

CP1P6G0096FC

Passive Harmonic Filters, 100 HorsePower, 600 Volts, 96 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 75 HorsePower, 600 Volts, 73 Amperes, 60 Hertz, Open Style, Contactor

CP1P6G0073FC

Passive Harmonic Filters, 75 HorsePower, 600 Volts, 73 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 60 HorsePower, 480 Volts, 74 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0074FC

Passive Harmonic Filters, 60 HorsePower, 480 Volts, 74 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 125 HorsePower, 600 Volts, 120 Amperes, 60 Hertz, Open Style, Contactor

CP1P6G0120FC

Passive Harmonic Filters, 125 HorsePower, 600 Volts, 120 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 60 HorsePower, 600 Volts, 59 Amperes, 60 Hertz, Open Style, Contactor

CP1P6G0059FC

Passive Harmonic Filters, 60 HorsePower, 600 Volts, 59 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 150 HorsePower, 480 Volts, 180 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0180FC

Passive Harmonic Filters, 150 HorsePower, 480 Volts, 180 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 50 HorsePower, 480 Volts, 61 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0061FC

Passive Harmonic Filters, 50 HorsePower, 480 Volts, 61 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 40 HorsePower, 480 Volts, 50 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0050FC

Passive Harmonic Filters, 40 HorsePower, 480 Volts, 50 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 200 HorsePower, 480 Volts, 241 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0241FC

Passive Harmonic Filters, 200 HorsePower, 480 Volts, 241 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 250 HorsePower, 480 Volts, 299 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0299FC

Passive Harmonic Filters, 250 HorsePower, 480 Volts, 299 Amperes, 60 Hertz, Open Style, Contactor

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring proper wiring and configuration.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Grounding wire

  1. Inspect the unit

    Immediately after receiving the HPS Centurion P Passive Harmonic Filter, inspect it for any transit damage and verify against the shipping documents. Report any damage to the carrier and HPS.

  2. Mount the filter

    Secure the filter to a suitable location using the provided mounting brackets and screws. Ensure there is adequate clearance for ventilation and maintenance.

  3. Ground the filter

    Connect the designated main grounding location of the filter to a proper ground. Ensure all connections are tight and secure.

  4. Wire the connections

    Connect the input terminals A1, B1, and C1 to the corresponding phases of the power supply. Connect the output terminals A2, B2, and C2 to the load. Refer to the nameplate for specific wiring instructions.

  5. Verify connections

    Use a multimeter to verify that all connections are correct and secure. Confirm that there is no voltage present before proceeding.

  6. Commission the filter

    After ensuring all connections are secure, energize the filter and perform initial testing using a power quality analyzer to measure total harmonic distortion and power factor.

  7. Calibrate if necessary

    If the initial measurements indicate issues, adjust the filter settings as needed and retest to ensure optimal performance.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.