Hammond Power CP1K6G0032F - Passive Harmonic Filters, 25 HorsePower, 480 Volts, 32 Amperes, 60 Hertz, Open Style
Hammond Power

CP1K6G0032F

UPC: 803423167059


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power CP1K6G0032F is an open-style passive harmonic filter designed for industrial applications. Engineered to address harmonic distortion, this unit operates at 480 Volts and 60 Hertz, with a rated current of 32 Amperes, suitable for a 25 HorsePower motor load. Its advanced HPS design significantly outperforms traditional harmonic filters. It typically reduces harmonic current distortion by 80%, bringing it down to 5% or less at full load. This substantial reduction in harmonics not only improves system efficiency but also helps to extend the lifespan of connected equipment by mitigating heat and stress caused by harmonic currents. Furthermore, the CP1K6G0032F actively corrects the true power factor, pushing it to over 95%. This power factor correction is crucial for reducing reactive power, minimizing utility penalties, and optimizing energy consumption. When operated within its designed parameters, this filter ensures compliance with IEEE 519 harmonic standards, a critical requirement for many modern industrial facilities to maintain grid stability and avoid regulatory issues. The open-style construction facilitates integration into existing control panels and electrical systems, offering a straightforward solution for harmonic mitigation.
  • The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
  • It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
  • HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
  • Rated for 25 HorsePower, 480 Volts, 32 Amperes, 60 Hertz
  • Open-style construction for easy integration

Specifications

Ambient Operating Temperature
0 to 40 Deg C
Application
For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants
Cooling
Natural Convection
Depth
9.8 IN
Enclosure
Open Frame
Enclosure Type
Open Style
Frequency
60Hz
Frequency Rating
60 HZ
Height
15.2 IN
Impedance
32A
Input Current
29 A
Length
20.1 in
Mounting
Wall/Ceiling/Floor Mount
Mounting Style
Wall/Floor
Output Current
32 A
Special Features
Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements.
Standard
cUL, IEEE 519-2014 compliant
Voltage
480 V
Voltage Rating
480V
Warranty
3 Years
Weight
100 L
Width
10.7 IN
Package Dimensions (L x W x H)
9.8 IN x 10.7 IN x 15.2 IN
Package Dimensions (L x W x H)
249 mm x 272 mm x 386 mm
Package Weight (Imperial)
100.000 L
Package Weight (Metric)
45.000 kg
Passive Harmonic Filters, 20 HorsePower, 480 Volts, 25 Amperes, 60 Hertz, Open Style

CP1K6G0025F

Passive Harmonic Filters, 20 HorsePower, 480 Volts, 25 Amperes, 60 Hertz, Open Style
Passive Harmonic Filters, 10 HorsePower, 480 Volts, 14 Amperes, 60 Hertz, Open Style

CP1K6G0014F

Passive Harmonic Filters, 10 HorsePower, 480 Volts, 14 Amperes, 60 Hertz, Open Style
Passive Harmonic Filters, 15 HorsePower, 480 Volts, 19 Amperes, 60 Hertz, Open Style

CP1K6G0019F

Passive Harmonic Filters, 15 HorsePower, 480 Volts, 19 Amperes, 60 Hertz, Open Style
Passive Harmonic Filters, 30 HorsePower, 480 Volts, 37 Amperes, 60 Hertz, Open Style

CP1K6G0037F

Passive Harmonic Filters, 30 HorsePower, 480 Volts, 37 Amperes, 60 Hertz, Open Style
Passive Harmonic Filters, 40 HorsePower, 480 Volts, 50 Amperes, 60 Hertz, Open Style

CP1K6G0050F

Passive Harmonic Filters, 40 HorsePower, 480 Volts, 50 Amperes, 60 Hertz, Open Style
Passive Harmonic Filters, 50 HorsePower, 480 Volts, 61 Amperes, 60 Hertz, Open Style

CP1K6G0061F

Passive Harmonic Filters, 50 HorsePower, 480 Volts, 61 Amperes, 60 Hertz, Open Style
Passive Harmonic Filters, 7.5 HorsePower, 480 Volts, 11 Amperes, 60 Hertz, Open Style

CP1K6G0011F

Passive Harmonic Filters, 7.5 HorsePower, 480 Volts, 11 Amperes, 60 Hertz, Open Style
Passive Harmonic Filters, 5 HorsePower, 480 Volts, 8 Amperes, 60 Hertz, Open Style

CP1K6G0008F

Passive Harmonic Filters, 5 HorsePower, 480 Volts, 8 Amperes, 60 Hertz, Open Style
Passive Harmonic Filters, 60 HorsePower, 480 Volts, 74 Amperes, 60 Hertz, Open Style

CP1K6G0074F

Passive Harmonic Filters, 60 HorsePower, 480 Volts, 74 Amperes, 60 Hertz, Open Style
Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Open Style

CP1P6G0006F

Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Open Style
Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Open Style

CP1P6G0008F

Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Open Style
Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Open Style

CP1P6G0012F

Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Open Style

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter, Forklift or hoisting equipment

Supplies needed:

Mounting screws, Terminal connectors, Grounding wire

  1. Inspect the unit

    Immediately after receiving the Passive Harmonic Filter, inspect it for any transit damage and ensure all parts are accounted for according to the shipping documents.

  2. Mount the filter

    Using a forklift or hoisting equipment, securely position the Passive Harmonic Filter in the designated installation location, ensuring at least 6 inches of clearance from walls for ventilation.

  3. Ground the filter

    Connect the designated main grounding location of the Passive Harmonic Filter to a suitable ground to ensure safe operation before energizing the unit.

  4. Wire the connections

    Connect the input terminals A1, B1, and C1 to the corresponding phases of the power supply, and connect A2, B2, and C2 to the load, following the nameplate diagram.

  5. Verify connections

    Use a multimeter to verify that all connections are secure and that there is no voltage present before proceeding to energize the unit.

  6. Energize the filter

    Once all connections are verified and secure, turn on the upstream circuit breaker to energize the Passive Harmonic Filter.

  7. Perform initial testing

    Use a power quality analyzer to measure total harmonic distortion and power factor before and after connecting the filter to quantify its performance.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.