
Contact for Pricing
Overview
- Hazardous Location Certified: UL and cUL CID2
- Operating Voltage: 24VDC
- Color: Magenta for high visibility
- In-Rush Limited for safe power transitions
- Manufacturer: Federal Signal
Specifications
-40 to 104 | DEG F |
0.70 (2.0 In-Rush) | A |
10,000 | HR |
24 | VDC |
580,000 | CND |
7.5 H x 5.5 W x 5.5 D | IN |
80 | FLPM |
Amperage | 0.70 (2.0 In-Rush) A |
Amperage Rating | 0.70 (2.0 In-Rush) AMP |
Application | Indoor/Outdoor |
Average Life | 10,000 HR |
Brand Name | Federal Signal |
Candela Power | 240 |
Candela Power Peak | 580,000 |
Candle Power | 580,000 CND |
Color | Magenta |
Diameter | 5.5 in (139.7 mm) |
Environmental Conditions | -40 to 104 DEG F |
Flashes Per Minute | 80 FLPM |
Flashing Pattern | 1x Flash |
Lens Color | Magenta |
Light Source | Strobe Tube |
Material | Zinc/Polycarbonate |
Model | 225XST-I |
Mounting | 1/2-Inch NPT Pipe |
NEMA Rating | Type 4X, IP66, IP69K Enclosure (Dome up orientation) |
Operating Temperature | -40D to +104DF (-40D to +40DC) |
Power Peak | 580000 |
Series | 225XST |
Series | Electraray |
Shape | Cylindrical |
Size | 7.5 H x 5.5 W x 5.5 D IN |
Special Features | Voltage In-Rush Limiting PCB Design |
Standard | UL Listed/cUL Listed/CSA Certified |
Standard | CSA,UL,cUL |
Style | Strobe |
Sub Brand | Electraray |
Type | Hazardous Location Strobe Warning Light |
Voltage Rating | 24 Vdc |
Package Dimensions (L x W x H) | 10 IN x 8 IN x 8 IN |
Package Dimensions (L x W x H) | 25.4 cm x 20.32 cm x 20.32 cm |
Package Weight (Imperial) | 2.000 L |
Package Weight (Metric) | 0.907 kg |

225XST-I-024A
Electraray Strobe Light, Hazardous Location, In-Rush Limited, UL and cUL CID2, 24VDC, Amber
224XSTHI-024C
Electraray Strobe Light, Supervised, Hearing Impaired, Hazardous Location, UL and cUL CID2, 24VDC, Amber
225XST-I-024B
Electraray Strobe Light, Hazardous Location, In-Rush Limited, UL and cUL CID2, 24VDC, BlueFrequently Asked Questions
What is the IP rating of the 225XST-I?
The 225XST-I is an IP69K rated product, designed for environments with high-pressure and high-temperature washdowns.
What type of product is the 225XST-I?
The 225XST-I is an Electraray® Hazardous Location Strobe Light.
What are the key features of IP69K rated products?
IP69K products are dust-tight and withstand high-pressure, high-temperature washdowns. They are designed for applications requiring sanitation and cleanliness.
What environments are suitable for IP69K products?
IP69K products are ideal for food and beverage, wastewater, pharmaceutical, marine, medical facilities, and medical equipment manufacturing applications.
What certifications does the 225XST-I meet?
The 225XST-I meets or exceeds UL, CSA, CSFM, and IECEx standards, among other global certifications.
What is the water spray temperature for IP69K testing?
During IP69K testing, water is sprayed at temperatures of 176°F (80°C).
What is the water spray pressure for IP69K testing?
IP69K testing involves water sprays of 1160–1450 psi.
What is the water spray distance for IP69K testing?
Water is sprayed from 4 different angles at a distance of 4–6 inches during IP69K testing.
How is IP69K different from NEMA Type 4?
IP69K protects from close-range, powerful, high-temperature water jets and is dust-tight. NEMA Type 4 involves high volume, low pressure water from a longer distance.
What testing does an IP69K product undergo?
IP69K products are dust-tight tested in an Arizona A2 Dust chamber and undergo high-pressure steam jet cleaning with water sprays of 1160–1450 psi at 176°F (80°C).
How to Install the 225XST-I-024M Strobe Light
This guide provides step-by-step instructions for installing and wiring the 225XST-I-024M strobe light, ensuring proper setup and safety.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Unpack and Inspect the Device
Carefully unpack the 225XST-I-024M strobe light and inspect it for any damage. Ensure all parts are present; if any are missing or damaged, do not proceed with installation and contact customer support.
- Mount the Strobe Light
Secure the strobe light to a 1/2" NPT threaded pipe, ensuring it is positioned with the dome facing upwards to prevent water accumulation. Tighten the fixture to a minimum of 5 ft-lbs (6.8 Nm) to ensure a secure connection.
- Wire the Device
Feed the wires through the conduit and connect them according to the wiring diagram: for DC models, connect the red wire to positive, black wire to negative, and green/yellow wire to earth (ground). Ensure all connections are secure and properly insulated.
- Test the Installation
After wiring, restore power to the unit and test the strobe light to verify it operates correctly. Establish a program for periodic testing and provide operational instructions to all personnel.
Frequently Asked Questions about Federal Signal
What certifications and standards do Federal Signal products comply with?
Federal Signal products are certified across multiple international standards, including UL (Underwriters Laboratories) in the USA, CSA (Canadian Standards Association), CE (European Community), UKCA (United Kingdom), EAC (Russia), and C-Tick (Australia and New Zealand). Their products meet rigorous safety and performance standards for industrial environments, with specific compliance in electrical equipment enclosures, functional safety, and environmental protection ratings.
What is Federal Signal's warranty policy?
Federal Signal offers a comprehensive limited warranty covering most products for 1-5 years from the date of delivery, with specific terms varying by product category. Mechanical sirens, beacons, speakers, and sounders typically receive 5-year parts and labor coverage, while electronic sirens and controllers generally have 2-year warranties. All warranties require return to the factory for service, and on-site services are not included. Certain components like domes, lenses, lamps, and batteries are specifically excluded from warranty coverage.
What industries and applications are Federal Signal products used for?
Federal Signal products are used across multiple critical industrial and municipal sectors for notification, communication, and safety systems. Their product lines cover essential applications including fire alarm systems, public address and telephony, outdoor warning systems, visual and audible signals, and emergency communication networks. Key industries served include manufacturing, municipal emergency services, industrial facilities, and infrastructure environments where clear, reliable communication and safety signaling are paramount.
What technical support does Federal Signal offer?
Federal Signal offers comprehensive technical support through their dedicated [email protected] email and direct phone line at +1 708.534.4756. Their support covers a wide range of notification and communication solutions, including technical assistance for products in public address, telephony, fire alarm, visual and audible signals, outdoor warning systems, and intercoms.
What are the main product lines offered by Federal Signal?
Federal Signal offers comprehensive notification and communication solutions across multiple product lines, including Visual Signals, Audible Signals, Telephony, Intercoms, Fire Alarm, Outdoor Warning Systems, Public Address, and Initiating Systems. Their product range is designed to provide clear communications and critical process notifications that enhance safety and compliance in industrial and public environments.
What are the key features of Federal Signal products?
Federal Signal products are comprehensive notification solutions designed to enhance safety and communication across industrial environments. Their key features include visual and audible signals, fire alarm systems, outdoor warning systems, public address capabilities, telephony, and intercoms. These products provide critical process notifications, ensure safety compliance, and offer advanced technologies like secure encrypted communication, cloud-based control systems, and customizable emergency response interfaces.
What environmental ratings do Federal Signal products have?
Federal Signal products offer robust environmental ratings across multiple standards, including UL 508A, CSA, NEMA, and IEC 60529. Their enclosures are rated for Type 1, 2, 3, 4, 4X, 12, and 13 environments, with IP66 protection, and can operate in temperatures ranging from -40°F to 266°F. These ratings ensure superior protection against dust, water, corrosion, and extreme conditions for indoor and outdoor industrial applications.
What accessories are available for Federal Signal products?
Federal Signal offers multiple accessories for their signaling products, including coupling kits, cable entry adapters, indicator rings, legend plates, and mounting brackets. Key accessories include E-Box endcap kits with M20 and M25 openings, U-Brackets for dual configurations, and color-coded indicator rings in black, blue, green, magenta, red, and yellow. Additional options like adapters for NPT connections and specialized mounting hardware are also available for their Global Series signaling platforms.
What communication protocols do Federal Signal products support?
Federal Signal supports multiple industrial communication protocols including PROFIBUS DP, PROFINET, EtherNet/IP, CANopen, and Modbus RTU. These protocols enable flexible network integration across various industrial automation environments, supporting both traditional fieldbuses and modern Ethernet-based communication standards.
How are Federal Signal products typically installed?
Federal Signal products are typically installed using professional mounting configurations that include wall brackets, base stations, and specialized mounting hardware. Depending on the specific product line—such as outdoor warning systems, visual signals, or audible signals—installation involves precise mounting options like wall-mount antenna brackets, base station radio packages, and modular component assemblies. Each product configuration includes specific mounting accessories like endcaps, adapters, and terminal blocks to ensure secure and compliant installation in industrial and safety-critical environments.





